Digital Insulation Megohmmeter 100V Chauvin Arnoux CA6531

Code: Chauvin Arnoux CA6531


 

Description

Perfectly suitable for tests on telephone lines or electronic equipment, the C.A 6531 megohmmeter measures insulation at 50V and 100V as well as resistances, current capacity and AC/DC voltage.

 

  • insulation: up to 400MO at 50V and 100V
  • AC voltage measurement: 0 to 400V
  • voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
  • resistance: 0 to 40kO
  • capacity: 0 to 4000nF
  • current: 0 to 400mA AC/DC
  • giant, 4000-count display + bargraph (simultaneous reading of the measurement and analogue variation)
  • backlit display
  • programmable alarms
  • DREL function for testing for the presence of transmission frame or measurement of the resistance difference of 2 wires of a pair
  • direct display in km of the length of the line being tested
  • remote control probe (option)
  • back stand for use on a table or on the ground
  • high autonomy: 6 b

 

 

 

Standard accessories

C.A 6531...................P01140804B

C.A 6533...................P01140805

 

½ 1 "hands-free" carrying case

½ 1 pair of 1.5 m leads, red + black

(the leads on C.A 6533 are guarded)

½ 1 red croc-clip

½ 1 black test probe

½ 2 wire grips, red + black

½ 6 LR6 batteries

½ 1 set of operating instructions.

* + 1 blue 1.5 m lead and 1 blue croc-clip for model C.A 6533

 

More products CHAUVIN ARNOUX

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6472

• 5 tools in 1 with this tester
• extensive measurement ranges: 0.001?to 100 k?
• analysing the frequency behaviour of the earthing systems (from 41 Hz to 5 kHz)
• high-level, expert calculation capabilities
• IP 53 leakproofing

 

TRANFORMER RATIO TESTER CHAUVIN ARNOUX DTR8510

• calculate the ratios
• NiMH battery life of up to 10 hours
• Automatic calibration and balancing
• Low-voltage test
• Digital display ½ display of ratios, winding direction - % deviation
• Degauss function

 

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6114

• automatic installation status test immediately after connection
• measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz)
• installation insulation measurement at 500V
• standard earth connection resistance measurement (1 stake + loop method)
• PE conductor continuity test
• measurement of internal loops
• testing of RCDs up to 500mA (exact tripping time and current)
• phase rotation testing

 

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV

 

DIGITAL INSULATION MEGOHMMETER 1KV CHAUVIN ARNOUX CA6525

• insulation: up to 2G? at 250V, 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


SOLAR PHOTOVOLTAIC PANELS TESTER CHAUVIN ARNOUX FTV200

• I-V curve with cursor
• Voltage measurement up to 1,000 VDC
• Current measurement up to 10 ADC
• Pyranometer up to 2,000 W/m2
• Mesure of r½sistance Rs
• 80 MB internal storage capacity
• More than 10,000 different panel references
• Possibility of external USB key for storage

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V