Digital Insulation Megohmmeter 100V Chauvin Arnoux CA6531

Code: Chauvin Arnoux CA6531


 

Description

Perfectly suitable for tests on telephone lines or electronic equipment, the C.A 6531 megohmmeter measures insulation at 50V and 100V as well as resistances, current capacity and AC/DC voltage.

 

  • insulation: up to 400MO at 50V and 100V
  • AC voltage measurement: 0 to 400V
  • voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
  • resistance: 0 to 40kO
  • capacity: 0 to 4000nF
  • current: 0 to 400mA AC/DC
  • giant, 4000-count display + bargraph (simultaneous reading of the measurement and analogue variation)
  • backlit display
  • programmable alarms
  • DREL function for testing for the presence of transmission frame or measurement of the resistance difference of 2 wires of a pair
  • direct display in km of the length of the line being tested
  • remote control probe (option)
  • back stand for use on a table or on the ground
  • high autonomy: 6 b

 

 

 

Standard accessories

C.A 6531...................P01140804B

C.A 6533...................P01140805

 

½ 1 "hands-free" carrying case

½ 1 pair of 1.5 m leads, red + black

(the leads on C.A 6533 are guarded)

½ 1 red croc-clip

½ 1 black test probe

½ 2 wire grips, red + black

½ 6 LR6 batteries

½ 1 set of operating instructions.

* + 1 blue 1.5 m lead and 1 blue croc-clip for model C.A 6533

 

More products CHAUVIN ARNOUX

ENERGY POWER ANALYZER AND MOTOR DIAGNOSTIC TESTER CHAUVIN-ARNOUX CA8220

• Voltage and current with instant display
• TRMS AC+DC value
• peak values and THD
• Short-term flicker measurement
• offers instant display of the waveform
• comprehensive power and energy analysis on both single-phase and three-phase systems
• Up to several days½ recording
• Customization of alarm settings

 

THREE-PHASE ENERGY ANALYZER CHAUVIN-ARNOUX CA8335 QUALISTAR PLUS

• - Voltage ratios: 1 V to 500 kV
• - Mixed sensors: 10 mA to 60 kA depending on sensor
• for quick verification of network quality and simple processing of the results

 

EARTH RESISTANCE TESTER CHAUVIN ARNOUX CA6421

• earth resistance: 0.5Oat 1,000 O (log scale) )
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• removable captive connection strip between S and H for 2-wire resistance measurements


DIGITAL INSULATION MEGOHMMETER 1000V CHAUVIN ARNOUX CA6523

• insulation: up to 2G? at 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8332B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (50th rank), flicker,
• - alarm trigger...
• Processing of data with DataView PC software.
• Working memory: 2MB

 

DIGITAL INSULATION MEGOHMMETER 100V CHAUVIN ARNOUX CA6531

• insulation: up to 400MO at 50V and 100V
• AC voltage measurement: 0 to 400V
• voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 40kO
• capacity: 0 to 4000nF
• current: 0 to 400mA AC/DC


DIGITAL INSULATION MEGOHMMETER 1KV CHAUVIN ARNOUX CA6525

• insulation: up to 2G? at 250V, 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)