Electrical Machine Certification Tester Chauvin Arnoux CA6160

Code: Chauvin Arnoux CA6160


 

Datasheet PDF, 0.68 Mb

Description

The C.A 6160 is a powerful portable instrument for complete certification testing of a broad range of electrical appliances and equipment: dielectric test, continuity, voltage drop, insulation resistance, leakage current, discharge time and functional testing.

 

  • dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
  • continuity: up to 100O with 0.1 < ITEST < 25A
  • voltage drop: up to 100V (Itest > 10A)
  • insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
  • measurement of internal and external discharge time (at the plug)
  • leakage current: operating and residual up to 20mA, contact up to 2mA
  • functional testing: voltage, current, frequency and power
  • AUTOTEST function for automatic execution of measurement sequence (up to 50)
  • large memory: 1,600 measurements
  • software to upload the stored data, generate test reports and program measurement sequences
  • delivered with all necessary measurement cables as standard and many optional accessories
  • dimensions: 410 x 175 x 370 mm - weight: 13.5kg

 

 

Standard accessories

Delivered with 1 power cord (EURO or GB), 2 dielectric test guns with 2m of cable, 2 3m insulation test leads (1 red, 1 black), 4 crocodile clips (2 red, 2 black), 2 test probes (1 red, 1 black), 4 x 2.5m continuity test leads (2 red, 2 black), 1 discharge time cable (EURO or GB), and 1 carrying bag for the accessories

 

Recommended options

 

 

More products CHAUVIN ARNOUX

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6547

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis of insulation: automatic calculation of DAR, PI and DD (dielectric discharge) ratios
• plotting of the R(t) curve

 

EARTH AND LOOP RESISTANCE TESTER CHAUVIN ARNOUX CA6456

• loop resistance and impedance: L-N, L-L, and L-PE from 0.20 to 4 kO
• short-circuit current displayed up to 40 kA by calculation (Uref/ZL-PE)
• clamp measurement of current and leakage current (option)
• Cat. III, 600V

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6114

• automatic installation status test immediately after connection
• measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz)
• installation insulation measurement at 500V
• standard earth connection resistance measurement (1 stake + loop method)
• PE conductor continuity test
• measurement of internal loops
• testing of RCDs up to 500mA (exact tripping time and current)
• phase rotation testing

 

MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V