Insulation Megohmeter 5kV Chauvin Arnoux CA6505

Code: Chauvin Arnoux CA6505


 

Datasheet PDF, 0.72 Mb

Description

The C.A 6505 makes industrial equipment inspection and maintenance testing particularly

simple.

 

  • Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments
  • 500 V: 10 kO to 2 TO
  • 1,000 V: 10 kO to 4 TO
  • 2,500 V: 10 kO to 10 TO
  • 5,000 V: 10 kO to 10 TO

 

In its site-proof casing suitable for even the severest conditions, the C.A 6505 offers optimum accuracy and expertise for insulation testing.

As soon as it is connected, it measures the voltage, frequency, capacitance and residual current values on the installation or equipment to be tested.

The C.A 6505 megohmmeter is delivered in a bag with 2 measurement leads 2 m long, crocodile clips and 2 guarded safety leads.

 

Standard accessories

½ C.A 6505 Megohmmeter ................................. P01139704

Delivered with a carrying bag containing:

½ 2 simplified measurement leads 2 m long, equipped with an HV plug at

each end (red / blue)

½ 1 guarded safety lead 2 m long, equipped with an HV plug at one end and

an HV plug with rear connection at the other end (black)

½ 1 guarded safety lead 0.35 m long, equipped with an HV plug at one end and

an HV plug with rear connection at the other end (blue)

½ 3 crocodile clips (red, blue and black)

½ 1 mains power cable 1.80 m long

½ 1 operating manual in 5 languages

 

 

Recommended options

 

 

More products CHAUVIN ARNOUX

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV

 

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6547

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis of insulation: automatic calculation of DAR, PI and DD (dielectric discharge) ratios
• plotting of the R(t) curve

 

EARTH RESISTANCE TESTER CHAUVIN ARNOUX CA6421

• earth resistance: 0.5Oat 1,000 O (log scale) )
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• removable captive connection strip between S and H for 2-wire resistance measurements


THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

DIGITAL INSULATION MEGOHMMETER 1KV CHAUVIN ARNOUX CA6525

• insulation: up to 2G? at 250V, 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

ENERGY POWER ANALYZER AND MOTOR DIAGNOSTIC TESTER CHAUVIN-ARNOUX CA8220

• Voltage and current with instant display
• TRMS AC+DC value
• peak values and THD
• Short-term flicker measurement
• offers instant display of the waveform
• comprehensive power and energy analysis on both single-phase and three-phase systems
• Up to several days½ recording
• Customization of alarm settings

 

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

ANALOGUE MEGOHMMETER 1000V CHAUVIN ARNOUX CA6513

• insulation: up to 1,000MO (1 cal.) at 500V and 1,000V DC
• AC voltage: 0 to 600V
• resistance: 0 to 1,000O
• continuity: -10O to +10O (I=200mA)
• automatic testing of voltage absence by direct measurement