YOKOGAWA Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A)

Cod: YOKOGAWA CL150


 

Brosura produs PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

1.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

.5?% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz)

Method of detection

Mean Value

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W) x 247(H) x 49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

Alte produse YOKOGAWA

YOKOGAWA CLAMP-ON TESTER CL130 (ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• Mean value display
• Data hold function

 

YOKOGAWA - DIGITAL LUX METERS 51000 51011 51012 51021

• Wide measurement range, high accuracy
• Spectral response characteristics for visible range
• Good oblique incident light characteristics
• USB communication and USB power supply
• Recorder output

 

YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR

• Frequency range: Sine wave 0.01 µHz to 30 MHz
• Amplitude resolution: 16 bits
• Sampling rate: 120 MS/s
• Output: 0 to 20 Volts, peak-to-peak

 

YOKOGAWA STAND CALIBRARE PRESIUNI PNEUMATICE MC100

• Low temperature coefficient Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C
• Divided output function with as many as 20 steps
• Auto-step output function
• Sweep output function

 

YOKOGAWA AQ1000 REFLECTOMETRU FIBRA OPTICA IEFTIN

• Wavelengths: 1310 / 1550 nm
• Dynamic ranges: 32 / 30 dB
• Size: 185 mm (W) × 116 mm (H) × 56 mm (D) ( 7.3" (W) × 4.6" (H) × 2.2" (D) )
• Weight: 660 g ( 1.46 Lbs )

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA AQ2212 FRAME CONTROLLER (9 SLOTS)

• Easy-to-view color display
• USB port for data storage
• Measurement module "hot-swapping" capability
• Remote monitoring and measurement through a LAN

 

YOKOGAWA AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA MULTIMETRU DIGITAL PORTABIL TY710

• Conforms to safety standards EN61010-1 1000V CAT., 600V CAT.
• Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
• Operating temperature range -20 to +55C
• Storage temperature range -40 to +70
• Closed Case Calibration

 

YOKOGAWA CLAMP-ON TESTER CL220 (AC/DC 300A)

• AC/DC current measurements with current ranges up to 300A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display
• Sleep function