YOKOGAWA Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A)

Cod: YOKOGAWA CL150


 

Brosura produs PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

1.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

.5?% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz)

Method of detection

Mean Value

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W) x 247(H) x 49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

Alte produse YOKOGAWA

YOKOGAWA 2558A AC VOLTAGE CURRENT STANDARD

• Output Divider
• Direct Readout of the Deviation
• Digital Display of Output
• Common Current Output Terminals
• High Accuracy
• High Stability

 

YOKOGAWA AQ1200 OTDR FIBRA OPTICA COMPACT PORTABIL

• Applicable for installation and maintenance
• Models with a wavelength dedicated for maintenance of live fibers.
• These tri-wavelength models has two ports.

 

YOKOGAWA CALIBRATOR DE PROCES CA300 CA310 CA320 CA330

• Basic Accuracy: 0.015% (Source&Meas. accuracy of Voltage mA)
• Simultaneously supplies 24V loop power and measure output signal with high accuracy
• Sub display displays span% of the source value
• HART/BRAIN comm. resistance (250O) embedded

 

YOKOGAWA - DLM2000 OSCILOSCOP DIGITAL MIXT CU CANALE ANALOGICE SI DIGITALE

• Lineup includes 200 MHz, 350 MHz, 500 MHz bandwidth models
• Lightweight and compact
• Large 8.4-inch LCD display
• Long memory: Up to 250 M points (with /M3 option)
• High speed sampling: Up to 2.5 GS/s (1.25 GS/s with 4 ch)

 

YOKOGAWA CLAMP-ON TESTER CL135 (TRUE RMS, ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• True RMS Display
• Data hold function

 

YOKOGAWA DIGITAL INSULATION TESTER MY40

• 3 1/2-digit LCD;
• For each rating, you can save as many as 20 measurements at desired memory address numbers.
• Four AA (R6P) batteries the tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.

 

YOKOGAWA GS610 SOURCE MEASURE UNIT

• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
• Basic accuracy: ±0.02% (DC voltage generation)
• Sweep output at up to 100-µ intervals
• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65535 points of source measure data in the internal memory

 

YOKOGAWA AQ2170 SERIES PORTABLE OPTICAL POWER METER (SIMPLE & COMPACT)

• Two versions of Power Meters to suit test application
• Compact and lightweight
• Rubber protector to prevent damage when dropped

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA71 CA51

• Autostep function
• Changes the output value in step form based on the setting from the divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.
• Online communication (CA71 only) RS-232C-compliant optically isolated interface
• Sweep function
• Linearly increases or decrease the output. The increasing/decreasing time can be set to either 16 or 32 seconds.
• Memory function
• Source values and measurements forming individual value sets can be saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets).
• Temperature monitor function

 

YOKOGAWA MANOMETRU DIGITAL MT220

• Measurement with DCV and DCA
• 24 V DC output
• Percent reading
• Error reading
• Measurement data memory