YOKOGAWA Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A)

Cod: YOKOGAWA CL150


 

Brosura produs PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

1.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

.5?% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz)

Method of detection

Mean Value

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W) x 247(H) x 49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

Alte produse YOKOGAWA

YOKOGAWA 2558A AC VOLTAGE CURRENT STANDARD

• Output Divider
• Direct Readout of the Deviation
• Digital Display of Output
• Common Current Output Terminals
• High Accuracy
• High Stability

 

YOKOGAWA - WT3000E ANALIZOR DE PUTERE DE PRECIZIE

• Basic power accuracy: 0.01% of reading
• Both 2 A and 30 A input elements can be installed in a single unit
• Good readability: 8.4-inch LCD and the range indicator LEDs
• Simultaneous measurement with 2 units (Up to 8 power input elements)
• Store function: 50 ms data storing interval

 

YOKOGAWA GS610 SOURCE MEASURE UNIT

• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
• Basic accuracy: ±0.02% (DC voltage generation)
• Sweep output at up to 100-µ intervals
• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65535 points of source measure data in the internal memory

 

YOKOGAWA MANOMETRU DIGITAL MT220

• Measurement with DCV and DCA
• 24 V DC output
• Percent reading
• Error reading
• Measurement data memory

 

YOKOGAWA - DLM4000 OSCILOSCOP DIGITAL SEMNALE MIXTE

• DLM4038 350MHz
• DLM4058 500MHz
• (Standard) 8 analog channels or 7 analog channels + 8 bit logic
• (/L16 option) 8 analog channels + 16 bit logic or 7 analog channels + 24 bit logic
• Motor control & inverter circuit development
• Reliable triggering
• Best in Class Deep Memory & Architecture
• Two fully independent zoom windows

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA AQ7280 OTDR REFLECTOMETRU MODULAR TESTARE FIBRA OPTICA

• Reliability: Robust design for operating under harsh field conditions. Proven operating system assuring stability, prompt response, and superior protection against software virus attacks.
• Ease-Of-Use: Dual operation mode by multi-touch touchscreen and hard-key buttons. Fully automatic measurement and easy-to-read analysis reports through new software applications.
• Speed: Lightning startup time. Multi-tasking operation to enhance productivity. Immediate reporting via wireless connectivity.

 

YOKOGAWA ANALIZOR CALITATE PUTERE CW500

• Power Measurement and Logging
• Power Quality Measurement
• User Support
• Analysis of Data and Report Generation

 

YOKOGAWA - DL350 INREGISTRATOR PORTABIL

• A4-sized compact chassis
• Simultaneous isolated inputs maximum
• AC/DC/Battery operated
• Vibration resistant

 

YOKOGAWA AQ6373B ANALIZOR SPECTRU OPTIC VIZIBIL 350 - 1200 NM

• Max safe input power: +20 dBm
• Level sensitivity: -80 dBm
• Dynamic range: ?60dB
• Single-mode, Multimode, and Large-core fibers
• Built-in optical alignment source