Sonda activa diferentiala de precizie pentru osciloscop 50MHz Testec TT-SI50

Cod: Testec TT-SI50, TT-SI51

 

Descriere

TT-SI 50 1:10, 50MHz

Bandwidth: 50MHz

Attenuation Ratio: x10

Accuracy: +/-1%

Input Impedance: 1,6MΩ, 7pF

 

Only connect to a grounded oscilloscope!

 

Input Voltage

            Differential Mode: +-70V (DC + peak AC) or 70Vrms

            Common Mode: +-700V (DC + peak AC) or 600Vrms

            Absolute max. Voltage: +-700V (DC + peak AC) or 600Vrms CAT I

 

 

TT-SI 51  1:100, 50MHz

Bandwidth: 50MHz

Attenuation Ratio: x100

Accuracy: +/-1%

Input Impedance: 4MΩ, 7pF

 

Only connect to a grounded oscilloscope!

 

Input Voltage

            Differential Mode: +-700V (DC + peak AC) or 600Vrms

            Common Mode: +-1400V (DC + peak AC) or 600Vrms

            Absolute max. Voltage: +-1400V (DC + peak AC) or 600Vrms CAT II

 

Power requirements (optional): removable battery pack (4x AA Cells) or Mains Adaptor 6VDC/90mA or regulated 9VDC/70mA

Dimensions (LxWxH): 111 mm x 22 mm x 14 mm

Length: BNC Cable 125 cm - Input Leads 50 cm

Weight: 300 g

Hardcase included

 

Alte produse TESTEC

SONDA PASIVA OSCILOSCOP ATENUARE 10X TESTEC TT-MF200

• TT-MF 212 10:1 - 1,2m, 250MHz
• TT-MF 216 10:1 - 1,6m, 220MHz
• TT-MF 220 10:1 - 2,0m, 190MHz


SONDA TENSIUNE OSCILOSCOP ATENUARE 1X/10X TESTEC TT-HF300

• TT-HF 312 1:1/10:1 - 1,2m, 30MHz/300MHz
• TT-HF 320 1:1/10:1 - 2,0m, 15MHz/230MHz


SONDA DE CURENT OSCILOSCOP INALTA PRECIZIE DC..5MHZ TTI I-PROBER 520

• I-prober 520 - PCB track Touch & Measure
• Current measurement from insulated probing of conductor
• Suitable for observation and measurement of current in PCB tracks, component leads and ground planes
• Wide dynamic range of 10mA to 20A peak to peak
• Wide bandwidth of DC to 5MHz
• Low noise figure equivalent to <6mA rms at full B/W

 

SONDA ACTIVA DIFERENTIALA INALTA TENSIUNE PENTRU OSCILOSCOP 70MHZ TESTEC TT-SI9010

• TT-SI 9010 1:100 / 1:1000, 70MHz
• TT-SI 9010A 1:100 / 1:1000, 70MHz


SONDA INALTA TENSIUNE OSCILOSCOP 40KV TESTEC TT-HVP40

• TT-HVP 40 1000:1, 300Hz
• Attenuation Ratio: x1000 @ 10 MΩ, x2000 @ 1 MΩ
• Input Impedance: 1000 MΩ
• Bandwidth: 300 Hz (-3dB)
• Max. Input Voltage: DC 40kV, AC 28kVrms (0..300Hz)
• Cable Length: 1,0 m


SONDA DE TEST SMD-URI PENTRU MULTIMETRU, RLC-METRU TESTEC TT-22100

• TT-22100 Cable Length: 100cm, Connector: 2x 4mm Plug
• TT-22110 Max. Current: 2A, Connector: BNC-Plug


SONDA PASIVA OSCILOSCOP ATENUARE 10X FRECVENTA INALTA TESTEC TT-HF500

• TT-HF 512 10:1 - 1,2m, 500MHz
• TT-HF 520 10:1 - 2,0m, 350MHz


SONDA PASIVA OSCILOSCOP ATENUARE 1X/10X TESTEC TT-MF300

• TT-MF 312 1:1/10:1 1,2m, 20MHz/250MHz
• TT-MF 316 1:1/10:1 - 1,6m, 13MHz/220MHz
• TT-MF 320 1:1/10:1 - 2,0m, 10MHz/190MHz


SONDA ACTIVA OSCILOSCOP FRECVENTE INALTE DC..1.3GHZ TESTEC TT-AP

• TT-AP 1300 x10, DC..1.3GHz
• Bandwidth: DC 1,3GHz
• Attenuation Ratio: x10
• Rise Time: <0,25ns


SONDA INALTA TENSIUNE OSCILOSCOP 15KV TESTEC TT-HVP 15HF

• TT-HVP 15HF 1000:1, 50MHz
• Attenuation Ratio: x1000 +/-1% @ 1 MΩ
• Accuracy: VDC +/-6% / VAC +/-6% @ 1kHz
• Input Impedance: 100 MΩ, 1 pF
• Bandwidth: 50 MHz (-3dB)