Sonda activa diferentiala osciloscop 100MHz Testec TT-SI

Cod: Testec TT-SI

 

Descriere

TT-SI 9101  1:10 / 1:100, 100MHz

Bandwidth: 100MHz

Attenuation Ratio1: x10 / x100

Accuracy: ± 2%

Rise Time: 3,5ns

Input Impedance: 4MΩ, 7pF

 

Only connect to a grounded oscilloscope!

 

Input Voltage

Differential Mode

            x10: +-70V (DC + peak AC) or 70Vrms

            x100: +-700V (DC +peak AC) or 700Vrms

 

Common Mode

            x10: +-700V (DC + peak AC) or 700Vrms

            x100: +-700V (DC +peak AC) or 700Vrms

 

Absolute max. Voltage

            x10: +-1400V (DC + peak AC) or 1000Vrms CAT III

            x100: +-1400V (DC +peak AC) or 1000Vrms CAT III

 

Output Voltage

            Swing: ± 7V (into 50kW load)

            Offset (typical): <± 5mV

            Noise (typical): 0,9mVrms

            Source Impedance: 50W

            CMRR (typical): -85dB@50Hz, -50dB@1MHz

 

 

 

TT-SI 9110  1:100 / 1:1000, 100MHz

Bandwidth: 100MHz

Attenuation Ratio: x100/x1000

Accuracy: +/-2%

Input Impedance: 4MΩ, 7pF

 

Only connect to a grounded oscilloscope!

 

Input Voltage

Differential Mode

            x100: +-140V (DC + peak AC) or 140Vrms

            x1000: +-1400V (DC +peak AC) or 1000Vrms

 

Common Mode

            x100: +-1400V (DC + peak AC) or 1000Vrms

            x1000: +-1400V (DC +peak AC) or 1000Vrms

 

Absolute max. Voltage

            x100: +-1400V (DC + peak AC) or 1000Vrms CAT III

            x1000: +-1400V (DC +peak AC) or 1000Vrms CAT III

 

Output Voltage

            Swing: +-1,4V (into 50kΩ load)

            Offset (typical): <+-5mV

            Noise (typical): 0,6mVrms

            Source Impedance (typical): 50Ω

            CMRR (typical): -80dB@60Hz, -50dB@1MHz

 

 

 

Power requirements: 4x AA Cells or Mains Adaptor 6VDC/200mA or regulated 9VDC/120mA

Dimensions (LxWxH): 207 mm x 83 mm x 38 mm

Length: BNC Cable 90 cm - Input Leads 30 cm

Weight: 500 g

Accessories: we recomend mains adaptor TT-SI NT

 

 

Alte produse TESTEC

SONDA PASIVA OSCILOSCOP ATENUARE 1X/10X TESTEC TT-MF300

• TT-MF 312 1:1/10:1 1,2m, 20MHz/250MHz
• TT-MF 316 1:1/10:1 - 1,6m, 13MHz/220MHz
• TT-MF 320 1:1/10:1 - 2,0m, 10MHz/190MHz


SONDA ACTIVA OSCILOSCOP FRECVENTE INALTE DC..1.3GHZ TESTEC TT-AP

• TT-AP 1300 x10, DC..1.3GHz
• Bandwidth: DC 1,3GHz
• Attenuation Ratio: x10
• Rise Time: <0,25ns


SONDA PASIVA OSCILOSCOP ATENUARE 10X TESTEC TT-MF200

• TT-MF 212 10:1 - 1,2m, 250MHz
• TT-MF 216 10:1 - 1,6m, 220MHz
• TT-MF 220 10:1 - 2,0m, 190MHz


SONDA TENSIUNE OSCILOSCOP ATENUARE 10X TESTEC TT-HF200

• TT-HF 212 10:1 - 1,2m, 300MHz
• TT-HF 220 10:1 - 2,0m, 230MHz


SONDA ACTIVA DIFERENTIALA OSCILOSCOP 200MHZ TESTEC TT-SI200

• TT-SI 200 1:10, 200MHz
• Bandwidth: 200MHz
• Attenuation Ratio: : x10
• Accuracy: ± 1%
• Rise Time: 1,75ns
• Input Impedance: 500kW / 7pF


SONDA PASIVA OSCILOSCOP ATENUARE 10X TESTEC TT-LF200

• TT-LF 212 10:1 - 1,2m, 150MHz
• TT-LF 216 10:1 - 1,6m, 130MHz
• TT-LF 220 10:1 - 2,0m, 100MHz


SONDA PASIVA OSCILOSCOP ATENUARE 1X/10X TESTEC TT-LF300

• TT-LF 312 1:1/10:1 - 1,2m, 15MHz/150MHz
• TT-LF 316 1:1/10:1 - 1,6m, 12MHz/130MHz
• TT-LF 320 1:1/10:1 - 2,0m, 10MHz/100MHz


SONDA INALTA TENSIUNE OSCILOSCOP 40KV TESTEC TT-HVP40

• TT-HVP 40 1000:1, 300Hz
• Attenuation Ratio: x1000 @ 10 MΩ, x2000 @ 1 MΩ
• Input Impedance: 1000 MΩ
• Bandwidth: 300 Hz (-3dB)
• Max. Input Voltage: DC 40kV, AC 28kVrms (0..300Hz)
• Cable Length: 1,0 m


SONDA TENSIUNE OSCILOSCOP ATENUARE 10X FRECVENTA INALTA TESTEC TT-HF400

• TT-HF 412 10:1 - 1,2m, 350MHz
• TT-HF 420 10:1 - 2,0m, 270MHz


SONDA INALTA TENSIUNE OSCILOSCOP ATENUARE 100X TESTEC TT-HV

• TT-HV 150 100:1, 300MHz
• TT-HV 151 100:1, 200MHz
• TT-HV 250 100:1, 300MHz