Tester izolatie 500V testare ESD Megger MIT415
PRODUS OBSOLET ( * SCOS DIN UZ )

Cod: Megger MIT415


 

Brosura produs PDF, 0.29 Mb

Descriere

• 10 V and 100 V ESD testing
• 25 V & 50 V signal cable insulation testing
• 250 V & 500 V Insulation testing up to 50 GO (500 V)
• Continuity testing at 200 mA or 20 mA from 0.01 O to 999 kO
• DC and TRMS AC voltage measurement
• Large backlit display
• Combined analogue and dual digital readout
• Weatherproof to IP54 
• Supplied with AA alkaline

 

The Megger MIT415 insulation and continuity tester is designed for electrical testing by utilities, industrial, commercial and domestic electricians. The wide range of test voltages makes the MIT415 series ideal for the engineer or technician involved with combined applications of both communications circuits and power circuits such as would be found in elevator service/repair and routine maintenance. The low test voltage insulation ranges also makes the MIT415 ideal for ESD testing.

The MIT415 replaces the well-established BMM2000ESD insulation tester, gives greater functionality with simplified operation, greater application range and an ergonomically designed case.

 

Accesorii standard

MIT400: basic CATIV 600 V with 250 V/500 V/1000 V insulation MIT400-EN

MIT410: as MIT400 + 50 V, 100 V, PI and DAR

MIT410-EN NSN:6625-99-354-2757

MIT415: 10 V, 25 V, 50 V, 100 V, 250 V, 500 V, PI and DAR 1000-351

MIT420: as MIT410 + result storage and recall + 200 GO

MIT420-EN NSN 6625-99-169-4728

MIT420-MIN: (NATO version - no batteries) 1000-309 NSN 6625-99-169-5675 MIT430: as MIT420 with Bluetooth download

MIT430-EN MIT40X: Special applications - selectable IT voltage 10-100 V MIT40X-EN

 

 

Included accessories

Hard case 5410-420

2 wire lead set to CAT IV 600 V, consisting of: Red and black leads, probes and clips with 1 x red long probe

Calibration certificate

SP5 Switched probe (not MIT400 or MIT40X) 1002-774

Owners information user guide CD

 

Optiuni recomandate

Optional accessories

Replacement 2 wire test lead set 1002-001

2 wire 500 mA fused test lead set 1002-015

Rubber boot with stand 6231-802

Pouch - test and carry case 2001-322

 

Alte produse MEGGER

TESTER RELEE DE PROTECTIE TRIFAZATE MEGGER SMRT33

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output - (45 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

TESTER IZOLATIE SI CONTINUITATE MEGGER MIT300 MIT310 MIT320 MIT330

• Extrem de ușor de utilizat
• Carcasă rezistentă din cauciuc
• Capac de protecţie autonom
• Avertizare circuit sub tensiune
• Rezistenţă la intemperii conform IP54

 

CLESTE MASURA REZISTENTA IMPAMANTARE MEGGER DET14C DET24C

• Elliptical clamp shape improves access to earth cables and straps up to 50 mm
• Low maintenance flat jaw interface
• Measures ground resistance from 0.05 O to 1500 O
• Measures true RMS ground leakage current from 0.5 mA rms to 35 A rms
• CAT IV 600 V safety rating
• Backlit LCD display

 

APARAT MASURA PRIZE DE PAMANT MEGGER DET3TC DET3TD

• 2 and 3 point testing
• ART (Attached Rod Technique) testing capability with DET3TC
• Choice of digital or analog display
• Warning indicators prevent test failure
• IP54 rated
• Complete with leads, stakes and rugged carry case
• Simple one button operation
• Calibration test certificate included

 

TDR 2-CANALE LOCALIZARE DEFECTE CABLU MEGGER TDR2000/3 1003-036, TDR2000/3P 1003-037

• best resolution of 0.1m the TDR2000/2 has a 20km maximum range
• Comprehensive Dual Channel capability with dual aspect display.
• AUTO set up mode for instant use.
• Ultra fast pulse for near end fault identification.
• Xpert guidance to potential fault.
• IP54 rating offers real life working.
• Designed for use on all metallic paired cables.

 

TESTER DE RELEE CONFORM IEC 61850 MEGGER GOOSER

• Reliable testing of IEC61850 relays using a conventional relay test set
• Separate Ethernet ports for the substation LAN and the controlling PC forming a Safe Substation Bus Access Point
• Seamless interaction between SCL GOOSE and GOOSE "sniffing"
• GOOSE merge - SCL GOOSE vs captured GOOSE for network troubleshooting and SCD file validation at FAT
• Stand alone functionality - Download a configuration and run

 

OHMMETRU INFASURARI TRANFORMATOARE 10A MEGGER MTO210

• Direct 2-channel digital reading (1 µO to 2000 O)
• DC test current up to 10 A maximum
• 0.25% measurement accuracy
• Integrated demagnetization feature
• Tests operation of on-load tap-changers
• Very fast auto safety discharge circuit

 

ANALIZOR CIRCUITE INTRERUPATOARE MEGGER TM1800

• Modular based design - user configurable TM1800 from nine different modules
• Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis
• Dual ground testing using DCM module - increased safety with both sides of breaker grounded
• Fast and easy testing - Select-Connect-Inspect workflow and high level user interface
• Graphical results for quick interpretation - timing and motion measurements, coil currents
• USB and Ethernet communication interface - for quick back up, LAN connection and printer options
• CABA Win - for advanced data analysis, database interface and common test data archive

 

PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER ODEN AT

• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Modular design to permit optimal user configuration of output current vs. unit size
• Compact transport cart facilitates portability into switchgear rooms with limited space
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result

 

MEGGER - B10E

• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing