Cod: Megger TDR2000/2 TDR2000/2RM TDR2000/2R
Descriere
• 20 km range at VF = 0.90
• Monochrome or colour options
• Primary cell or rechargeable options
• Large back lit LCD Display
• Dual cursor measurement
• Intermittent fault location
• Output pulse amplitude and width control
• "TX Null" technology
• No blocking filter required
• Trace Master PC software included
• 15 memory trace storage
• IP54 Rating
• 2 year Warranty
The MEGGER TDR2000/2 is a state of the art, monochrome or colour, dual channel Time Domain Reflectometer, capable of identifying and locating a wide range of faults on metallic cables.
The TDR2000/2 has a minimum resolution of 0.1m and a maximum range of 20 km at VF=0.9 and 16 Km at 0.65 VF. The TDR2000/2 can perform single or dual channel measurements on a wide range of metallic cables. Active channels can be compared with each other or with previously stored traces from memory. Differential channel measurements are possible and cross talk between channels can also be identified.
Accesorii standard
TDR2000/2RM Monochrome Rechargeable TDR2000/2RM
TDR2000/2R Colour Rechargeable TDR2000/2R
Included Accessories
Test and carry Pouch 6420-114
Serial data lead 25955-025
2 x Miniature Clip Test Lead Set 6231-654
Carry Strap for Pouch 6220-611
Tracemaster software 6111-458
User Guide 6172-662
Included Accessories TDR2000/2R Only
Battery charger
Optional Accessories
Dual fused test lead set (2 pairs) 1002-136
Battery charger UK mains 6121-538
Battery charger US mains 6121-539
Battery charger European mains 6121-605
Single fused lead set (1 pair) 1002-015
Alte produse MEGGER
|
EARTH LEAKAGE CLAMPMETER MEGGER - DCM305E
• 0.001 mA resolution
|
|
KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER � KF875 AND KF-LAB MKII
• Coulometric Karl Fischer titrimetry
|
|
SARCINA TESTARE DESCARCARE BATERII UPS-URI MEGGER TORKEL-840 TORKEL-860 BS-49094 BS-49096
• used for battery systems ranging from 12 to 250 V |
|
TRUSA ELECTRICIAN INSTALATII ELECTRICE MEGGER MTK310 MTK320 MTK330
• Three kit options available: Insulation, continuity, earth loop, RCD testing |
|
TRUSA COMPLEXA PENTRU VERIFICAREA RELEELOR DE PROTECTIE MEGGER FREJA 400
• FREJA 403 3x60 A at 300 VA per phase. |
|
ANALIZOR RASPUNS IN FRECVENTA TRANSFORMATOARE DE PUTERE MEGGER FRAX
• Frequency range 0.1 Hz – 25 MHz, user selectable |
|
SINGLE PHASE HAND CRANKED TRANSFORMER TURNS RATIO TESTER MEGGER - TTR550005B
• Used for testing single phase power and distribution transformers
|
|
TESTER DE IZOLATIE SI CONTINUITATE CU ALARMA MEGGER - MIT200 SERIES
• Sunt disponibile doua sau trei tensiuni de test asigur�nd solutia ideala pentru majoritatea aplicatiilor din zona tensiunilor joase
|
|
APARAT PENTRU MASURAREA RIGIDITAII DIELECTRICE A ULEIULUI ELECTROIZOLANT MEGGER OTS60AF OTS80AF OTS100AF
• Test voltages : 60 kV, 80 kV and 100 kV |
|
MULTIFUNCTION INSTALLATION TESTERS MEGGER - MFT1735
• Two and three wire non-trip loop testing for RCD protected circuits
|