Tester portabil masurare rezistenta continuitate si izolatie in salile medicale HT Italia Equitest5070
PRODUS OBSOLET ( * SCOS DIN UZ )

Cod: HT Italia Equitest5070


 

Brosura produs PDF, 0.3 Mb

Descriere

  • Continuity of earth conductors with <12VAC and >10A test current
  • Voltage drop measure
  • 4-wire method without test leads calibration
  • Wide LCD Custom display
  • Save measured results
  • Recall saved dates at display
  • RS-232 serial port for PC connection
 

Accesorii standard

  • C7000: set 2 cables with alligator clips, 3m
  • C2032-2MM: power supply cord
  • WP1991N: carrying bag
  • ISO 9000 calibration certificate
  • User manual
 

Optiuni recomandate

  • TOPVIEW: Windows software + RS-232 serial cable C232NG1
  • 1066-IECN: connector for banana cable 4mm, black
  • 1066-IECR: connector for banana cable 4mm, red
 

Alte produse HT ITALIA

MULTIMETRU PORTABIL VERIFICARE CABLU RETEA LAN VDE HT ITALIA M75

• DC Voltage
• AC TRMS Voltage
• Continuity test of protective conductors with 200mA
• Insulation Resistance measurement with 500VDC
• Global Earth Resistance without RCD tripping
• Test executed on twisted pairs cables UTP and STP with RJ45 connector
• Quickly selection of cables pairs

 

TESTER TENSIUNE DE PAS SI DE CONTACT CURENT MAXIM 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

INREGISTRATOR TENSIUNE AC RETELE ELECTRICE MONO/ TRI-FAZICE HT ITALIA XL423/ XL424

• TRMS AC Voltage measure up to 600V
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

ANALIZOR AUDIO CLASA 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC

 

MULTIMETRU CALIBRATOR DIGITAL PORTABIL DE PROCES HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

CLESTI DE CURENT AMPERMETRICI PORTABILI HT ITALIA

• DC/AC/AC+DC TRMS current
• DC/AC/Ac+DC TRMS Voltage
• Peak of AC current and AC voltage

 

HT SOLAR I-VE ANALIZOR MULTIFUNCTIONAL SISTEME FOTOVOLTAICE CURBA I-V

• Trasor curbă I-V multifuncţional 1500V pentru teste de întreţinere şi eficienţă la instalaţiile monofazate.
• Măsurarea eficienţei unui sistem fotovoltaic monofazat
• Măsurarea curbei I-V a unui modul sau a unui şir până la 1500V/10A - 1000V/15A
• Măsurarea tensiunii de circuit deschis a unui modul sau a unui şir (VOC) 1500V
• Măsurarea curentului de scurtcircuit al unui modul sau al unui şir (ISC) 15A

 

TESTER DIGITAL MASURARE PRIZE DE PAMANT SI REZISTENTA BUCLA IMPAMANTARE RCD HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

INREGISTRATOR CURENTI RETEA ELECTRICA MONO/ TRI-FAZICA HT ITALIA XL421/ XL422

• TRMS AC current measure up to 2500A
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

PV-ISOTEST TESTER SECURITATE ELECTRICA PANOURI SOLARE CU FUNCTIE DETECTIE PANOU DEFECT

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA