Multimetru masura izolatie si continuitate conductoare de protectie 1000V HT Italia ISO410
PRODUS OBSOLET ( * SCOS DIN UZ )

Cod: HT Italia


 

Brosura produs PDF, 0.38 Mb

Descriere

  • Continuity test with 200mA
  • Insulation with 50, 100, 250, 500, 1000VDC
  • Measure with remote probe (PR400 optional accessory)
  • Contextual help at display
  • Internal memory
  • Optical-USB interface with PC connection
 

Accesorii standard

  • UNIVERSALKIT: set of 3 cable + 3 alligator clips + 1 test lead
  • BORSA75N: carrying bag
  • Calibration Certificate ISO9000
  • Instruction manual on CD-ROM
  • Quick reference guide
 

Optiuni recomandate

  • TOPVIEW2006: Windows software + optical/USB cable
  • PR400: remote probe for activation tests
  • 404-IECR: red test lead
 

Alte produse HT ITALIA

TERMOMENTRE FARA CONTACT INFRAROSU HT ITALIA

• Infrared temperature measurement from -50°C to 1000 °C
• Emissivity regulation
• Distance / Spot ratio of 50:1
• Laser pointer activation

 

TESTER TENSIUNE DE PAS SI DE CONTACT CURENT MAXIM 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

HT PVCHECKS-ONE TESTER VERIFICARE SI PUNERE IN FUNCTIUNE SISTEME FOTOVOLTAICE PANA LA 1000V / 30A

• Continuitatea circuitului de protecție cu 200mA
• Polaritate
• Tensiunea în circuit deschis Voc a modulelor fotovoltaice și a șirurilor 1000V
• Curent de scurtcircuit Isc pe modulele fotovoltaice și șiruri 30A
• Izolația șirului/câmpului fotovoltaic cu tensiune de testare 250, 500, 1000VDC
• Măsurarea indicelui de polarizare P.I.
• Raport de absorbție dielectrică D.A.R
• Funcție GFL pentru localizarea poziției defectului în șir
• Categorie de măsurare CAT III 1000V
• Funcție OPT pentru testarea izolației pe șiruri fotovoltaice în prezența dispozitivelor MLPE

 

ANALIZOR AUDIO CLASA 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC

 

CLESTE DE CURENT AMPERMETRIC CU CAMERA INFRAROSU INTEGRATA HT9025T SI 1500V DC

• TRMS
• Interval de măsurare a curentului 1000A
• Curent AC/DC AC+DC
• Tensiune AC/DC 1000VAC/1500VDC
• Rezoluție IR 120 x 120 pxl

 

TESTER SECURITATE SISTEME PANOURI FOTOVOLTAICE HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell

 

HT SOLAR I-VE ANALIZOR MULTIFUNCTIONAL SISTEME FOTOVOLTAICE CURBA I-V

• Trasor curbă I-V multifuncţional 1500V pentru teste de întreţinere şi eficienţă la instalaţiile monofazate.
• Măsurarea eficienţei unui sistem fotovoltaic monofazat
• Măsurarea curbei I-V a unui modul sau a unui şir până la 1500V/10A - 1000V/15A
• Măsurarea tensiunii de circuit deschis a unui modul sau a unui şir (VOC) 1500V
• Măsurarea curentului de scurtcircuit al unui modul sau al unui şir (ISC) 15A

 

GSC60 TESTER MULTIFUNCTIONAL INSTALATII ELECTRICE CU ANALIZA CALITATE PUTERE

• TESTARE SIGURANȚĂ ELECTRICĂ CEI 64-8
• Rezistența la pământ cu metoda Wenner cu 4 fire.
• Teste diferențiale tip A, AC, B, B+, F până la 1A
• Măsurarea și înregistrarea parametrilor electrici
• Tensiuni, Curenți, Puteri, Energii, cosphi, etc.) în sisteme monofazate și trifazate

 

TRUSA MASURAREA TENSIUNII DE PAS SI ATINGERE CONTACT HT2055

• TRMS
• Interval de măsurare 200Ω
• Rezistență la împământare prin metoda cu 2 și 3 fire
• Rezistență la împământare prin metoda cu 4 fire
• Compensarea tensiunilor perturbatoare
• Compensarea cablurilor de testare
• Măsurarea tensiunii de pas/contact

 

CLESTI DE CURENT AMPERMETRICI PORTABILI HT ITALIA

• DC/AC/AC+DC TRMS current
• DC/AC/Ac+DC TRMS Voltage
• Peak of AC current and AC voltage