GOODWILL INSTEK GLC-9000

Cod: GOODWILL INSTEK GLC-9000 GLC9000


 

Brosura produs PDF, 1.53 Mb
   

Descriere

The GLC-9000, leakage current tester, is used to perform leakage current (or called touch current) tests on medical electrical (IEC 60601-1) and general purpose electric & electronic (IEC 60990) equipment. This tester engages with nine measurement networks (or called Measuring Device) to provide the simulation of human body while the EUT (equipment under test) is taking a leakage current testing in compliance with the specific standards or regulations such as IEC, UL, JIS...etc..

 

In order to provide a simple operation environment, the GLC-9000 equips with large TFT LCD touch panel to configure system as well as to present the measurement settings information and result simultaneously. Besides, there are 50 preset testing conditions, which conform to IEC60990 and other standards, for general electric equipment can be recalled to reduce the setting time. In addition, 30 sets empty memory are available for user defined setting.

 

A Meter mode is also available for the GLC-9000, it uses the measurement terminal (T1/T2) to measure voltage as the same way of ordinary voltmeter. During the voltage measurement, the SELV function (safety extra low voltage) is applicable to detect whether the voltage value between measuring points exceed the SELV setting.

 

Features:

  • Touch Panel with Color LCD Display
  • 9 Different Measurement Network to Simulate the Resistance of Human Body
  • 8 Different Types of Leakage current for Medical & General Electrical Equipment
  • Various Leakage Current Measuring Mode:DC/AC/AC+DC/AC Peak
  • Upper & Lower Limitation for PASS/FAIL Judgment
  • Meter Mode with SELV/CONV Function
  • 50 Preset Test Conditions Conform to IEC 60990; 30 Sets Memories for Customer Defined
  • Various Standard Interfaces:RS232/GPIB/USB Host & Device/EXT I/O
 

Alte produse GW INSTEK

GOODWILL INSTEK GFC-8010H

• 10Hz ~ 120MHz Range
• 8 Digits Display (0.3"LED)
• 15mV rms High Sensitivity
• 5PPM High Stability Time Base
• Frequency and Period Measurement

 

GOODWILL INSTEK GPT-9900 SERIES

• Function Key for quick selection
• High intensity flash for caution & Status indication
• Safety INTERLOCK function
• Zero Crossing Turn-on Operation
• Controllable Ramp-up Time

 

GOODWILL INSTEK GFC-8270H & GFC-8131H

• Frequency and Period Measurement
• High Resolution at Both High and Low Frequency
• 0.01Hz~2.7GHz Frequency Range(GFC-8270H)
• 0.01Hz~1.3GHz Frequency Range(GFC-8131H)
• 10mV rms High Sensitivity

 

OSCILOSCOP DIGITAL 2 CANALE 70/100/150MHZ INSTEK GDS-1000A-U

• 150/100/70MHz Bandwidths
• 1GSa/s Real-Time Sample Rates Maximum, 25GSa/s Equivalent-Time
• 2Mega Points Record Length
• 2mV~10V Vertical Scale
• 1ns~50s Horizontal Range
• Up to 27 Automatic Measurements
• 5.7" TFT LCD Display
• USB Host and Device Interface Supported
• Go/NoGo Function
• Data Logger

 

GOODWILL INSTEK SPS-SERIES

• 0.01 % High Regulation
• Constant Voltage and Constant Current Operation
• High Efficiency
• High Power Density

 

GOODWILL INSTEK GUT-6000B

• Loop Test
• Auto-Search
• Self-Diagnosis
• Over-Load Protection

 

GOODWILL INSTEK PPH-1503

• High Measurement REsolution (1mV/0.1mA for 5A Range);(1mV/0.1uA for
• 5mA Range)
• EXternal Relay Control Output On/Off
• Sink Current Capability (Maximum:2A)
• Digital Panel Control

 

GOODWILL INSTEK GLC-9000

• Touch Panel with Color LCD Display
• 9 Different Measurement Network to Simulate the Resistance of Human Body
• 8 Different Types of Leakage current for Medical & General Electrical Equipment
• Various Leakage Current Measuring Mode:DC/AC/AC+DC/AC Peak

 

GOODWILL INSTEK APS-1102A

• Arbitrary Waveform Power Output
• Power Amplifier of External Signal
• Measurement Functions: Voltage, Current, Power ,Frequency, Power Factor,CF,and Harmonic Current
• Capacitor Input Load Supported

 

GOODWILL INSTEK PSU-SERIES

• C.V/ C.C priority mode
• Adjustable voltage/current rise and fall time
• 1U height and 19½Rack Mount Size
• Bleeder Control function
• Internal Resistance function