Brand: FLUKE BIOMEDICAL

Tester monitorizare neutroni Fluke Biomedical 190N

Cod: Fluke Biomedical 190N


 

Descriere

  • Auto-scaling measurement of rate and dose (integrate mode includes dose and time accumulation)
  • True Rem readings recorded across a wider (lower and higher) rate range
  • Ergonomic, portable design: adjustable shoulder strap and rugged handle with padded grip
  • Flexible detector assembly, 190 can be removed for remote readings
  • Available in SI units

 

The self-contained 190N measures mRem in accordance with the classical Anderson and Braun design. The neutron probe can be attached to either a 190 Survey Meter or a 190F Frisker for continuous neutron surveys or area monitoring.

Neutron Probe, RP-N, can be interfaced to the 190F Frisker, with ac power for continuous monitoring.

 

Accesorii standard

  • 190N Portable Neutron Survey Meter 
  • 190N-SI Portable Neutron Survey Meter, SI Unit 
 

Alte produse FLUKE

DETECTOR DIGITAL MONITORIZARE RADIATII FLUKE BIOMEDICAL PRIMALERT 05-443/ 05/444

• LED digital display
• Low and High alarm indicators
• Programmable alarm indicator
• Optional remote
• Detector Fail indicator
• Battery backup
• Data output/RS-232

 

ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL DALE 601E

• Small, lightweight, self-contained portable instrument
• Master range meter delivers accurate measurment for each test
• Accurate test measurements with 4-wire Kelvin bridge
• Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
• Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
• All Leakage Current measurements are displayed directly in µAmps
• Broad range of external measurements
• Five (5) Universal EKG Lead Connectors
• The DALE601E is designed for 230 V operation


TESTER DIGITAL SECURITATE ELECTRICA ECHIPAMENTE MEDICALE FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


TESTER ENDOSCOAPE RIGIDE FLUKE BIOMEDICAL DALE301

• Incoming acceptance inspection performed
• Simple to use
• Lightweight and companct
• No light source or other accessories required


TESTER DETECTOR RADIATII ALFA, BETA, GAMMA, RAZE X FLUKE BIOMEDICAL ASM-990

• Auto-scaling measurement of rate and dose simultaneously, with the capability to record peak rate
• Up to [5] different probes can be calibrated with one unit
• Survey Mode data logging feature allows user to store up to 5 separate survey sequences
• Saved data can be uploaded to a PC via included Infrared Data (IrDA) transmitter
• Easy-to-use multifunction keypad for intuitive menu navigation
• Backlit analog/digital LCD display with full-range audio output capability

 

ANALIZOR ECHIPAMENTE ELECTRO-CHIRURGIE FLUKE BIOMEDICAL QA-ES

• Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor
• High-frequency leakage measurements with accuracy of ± 2 % of reading
• 128 internal user-selectable test loads from 10 O to 5200 O
• Ansur QA-ES software plug-in for automated test protocols
• RS-232 and Centronic-printer interface

 

ANALIZOR INFUZII TESTARE POMPE FLUKE BIOMEDICAL IDA 4 PLUS

• Tests up to four infusion pumps simultaneously
• Compatible with virtually any type of infusion device
• Instantaneous and average flow measurement
• Occlusion pressure measurements to 45 psi
• Single- and dual-flow (piggyback) testing

 

DEFIBRILATOR STIMULARE IMPULSURI FLUKE BIOMEDICAL 6000D/ 7000DP

• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
• AED technology compatibility
• First-class measurement accuracy ± 1 % of reading + 0.1 J
• Intuitive user interface and backlight, easy-to-read display
• Portable, rugged, easy to carry

 

TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Handheld portability (fitting in a briefcase)
• Self-switching 120/240 V operation
• Patient-lead-leakage testing
• 15 A and 20 A capabilities
• Digital accuracy
• Dual-lead testing

 

TESTER CAMERE IONIZARE PRESURIZATE RADIATII GAMMA, RAZE X FLUKE BIOMEDICAL 451P

• High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
• Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm
• Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case