Brand: FLUKE BIOMEDICAL

Analizor securitate electrica Fluke Biomedical DALE 601E

Cod: Fluke Biomedical DALE 601E


 

Descriere

  • Small, lightweight, self-contained portable instrument
  • Master range meter delivers accurate measurment for each test
  • Accurate test measurements with 4-wire Kelvin bridge
  • Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
  • Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
  • All Leakage Current measurements are displayed directly in µAmps
  • Broad range of external measurements
  • Five (5) Universal EKG Lead Connectors
  • The DALE601E is designed for 230 V operation

 

 

Specifications

Mains Voltage

 

 230 Volts, 50/60 Hz

Instrument Current

Range:

 0 - 10.00 Amps

Resolution:

 10 mA

Accuracy:

 5 % R

Ground (Earth) Resistance

Range: 0 - 1.99

 Accuracy: 1% R ± 1 LSD

              2 - 19.99

 Accuracy: 2 % R ± 1 LSD

Resolution:

 10 mOhms

Leakage Current

Range:

 0 - 1, 999 µA

Accuracy:

 DC & 25 Hz - 1kHz: ±1% of reading, ± 3LSD

 

 1.0KHz - 100 KHz: ±2.5% of reading, ± 3LSD

 

 100 KHz - 1 MHz: ±5% of reading, ± 3LSD

Type Measurement:

 True RMS

Test Load:

 AAMI or IEC601-1 (selectable)

Current Consumption

Range:

 0-14.99A(Dale 601-1515)

 

 0-19.99A(Dale 601-1520/2020)

 

 0-9.99A(Dale 601E)

Current Capacity

Dale 601-1515

 15Amps

Dale 601E

 10Amps

Dale 601-1520/2020

 20Amps, 20% duty cycle (2 minutes on, 8 minutes off)

Controls

 

 1. Function Switch - 9 position rotary

 

 2. Lead Switch - 6 position rotary

 

 3. Neutral Switch - 2 position rocker (Open/Closed)

 

 4. Polarity Switch - 3 position rocker (Normal/Off/Reversed)

 

 5. Leakage Switch - 2 position rocker (Chassis/Earth)

DUT Power

 

 10 Amps @ 230 V

Physical Size

 

 4.0 x 7.8 x 1.6 inches (102 x 196 x 41 mm)

 

Alte produse FLUKE BIOMEDICAL

TESTER DIGITAL SECURITATE ELECTRICA ECHIPAMENTE MEDICALE FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993


TESTER MULTIFUNCTIONAL PARAMETRI PRESIUNE DIFERENTIALA, VACUUM, TEMPERATURA FLUKE BIOMEDICAL DPM4

• Palm size
• High accuracy
• Differential pressure, vacuum, and temperature measurements
• Multiple user-selectable units of measurement
• Simultaneous display of multiple parameter measurements
• Leak detection/leak-rate calculation
• RS232 for computer control

 

ANALIZOR SECURITATE ELECTRICA SALI MEDICALE FLUKE BIOMEDICAL ESA612

• Portable, ergonomic, lightweight, and easy to use
• Large, easy-to-read display with adjustable contrast
• Human-factors-designed user interface
• Tilt stand design for stand-up testing in field environments
• Five applied parts jacks and easy ECG snap connection

 

ANALIZOR ECHIPAMENTE ELECTRO-CHIRURGIE FLUKE BIOMEDICAL RS303 RS

• New Signal Averaging Mode (SAMTM)
• New RS232 port
• Battery powered for completely isolated measurement
• Digital display
• HF-leakage-current measurement
• 4-digit numeric LCD with backlight and power-save mode

 

RADIOMETRU FOTOTERAPIE MASURA RADIATIE LUMINA FLUKE BIOMEDICAL DALE40

• Large LCD
• Accurate to ±5% of full scale
• Spectral range of 429-473 nm
• Complete portability


ANALIZOR CONCENTRATIE OXIGEN O2 FLUKE BIOMEDICAL MAXO2 PLUS AE

• One-touch calibration, with reminder
• Long battery life (approx. 5,000 hrs)
• Impact resistant and drip proof
• External MAX-250E Oxygen Sensor

 

RATMETRU DIGITAL UNIVERSAL MONITORIZARE RADIATII FLUKE BIOMEDICAL 942A/ 946A/ 952A

• User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
• Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
• Small front panel size allows dedicated display for each channel while minimizing panel space
• Ability to use existing cables when replacing most analog readouts

 

TESTER PNEUMATIC GENERARE/ MASURA PRESIUNI POZITIVE/ NEGATIVE FLUKE BIOMEDICAL DPM1B

• Battery operated
• Generates and measures positive or negative pressures
• Operates with gas and liquid
• Troubleshooting with 1 % accuracy

 

TESTER ENDOSCOAPE RIGIDE FLUKE BIOMEDICAL DALE301

• Incoming acceptance inspection performed
• Simple to use
• Lightweight and companct
• No light source or other accessories required


ANALIZOR ECHIPAMENTE ELECTRO-CHIRURGIE FLUKE BIOMEDICAL QA-ES

• Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor
• High-frequency leakage measurements with accuracy of ± 2 % of reading
• 128 internal user-selectable test loads from 10 O to 5200 O
• Ansur QA-ES software plug-in for automated test protocols
• RS-232 and Centronic-printer interface