Calibrator multifunctional de proces Fluke 725Ex

Cod: Fluke 725Ex


 

Brosura produs PDF, 0.53 Mb

Descriere

  • 0 to 100 mV, 0 to 30 V DC Voltage measure
  • 0 to 100mV, 0 to 10 V DC Voltage source / simulate
  • 0 to 24 mA Current measure / source / simulate
  • 0 to 3200 O Resistance measure / source / simulate
  • 1 to 10 kHz Frequency measure / source / simulate
  • ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X
  • I.S. Class I, Division 1 Groups B-D, 171°C compliance
  • Two separate channels; measure, source and view process signals simultaneously
  • Small, streamlined shape makes it easy to carry
  • Rugged, reliable design stands up to field use
  • Easy to read measure/source screen lets you view input and output simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Support flow meter testing with frequency and CPM functions
  • Perform fast linearity tests with auto- step and auto-ramp features
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms
  • Store frequently used test setups for later use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes
 

Accesorii standard

  • One set of AC72 alligator clips
  • One set of stackable test leads
  • One set of TL 75 testleads
  • User manuals
  • NIST- traceable calibration report and data
 

Alte produse FLUKE

FLUKE TIS60 CAMERA DE TERMOVIZIUNE 260X195

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE TIX500 CAMERA DE TERMOVIZIUNE 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

FLUKE TIS10 CAMERA DE TERMOVIZIUNE 80X60

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

CLESTE CURENT CALIBRARE PROCES FLUKE 771

• 0 to 21 mA, 10 to 50 mA Current measure
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity

 

ANALIZOR DE BATERII STATIONARE TESTARE REZISTENTA INTERNA FLUKE BT510

• Masuratori cheie: Rezistenta, tensiunea c.c. si c.a., intensitatea c.a. si c.c., variatia de tensiune ale bateriei, frecventa si temperatura bateriei.
• Analiza îmbunatatita a datelor: Comparati rapid tendinte, analizati rezultate si creati rapoarte cu ajutorul software-ului de gestionare a bateriei.
• Raportare usoara: Generati rapoarte PDF pe software-ul PC cu grafice de analiza si tabeluri de date sau trimiteti formatul raportului prin e-mail cu un fisier csv pe aplicatia mobila.
• Comunicatie wireless
• Port USB

 

SISTEM MENTENANTA SI INTRETINERE INSTALATII INDUSTRIALE FLUKE CNX 3000 GM

• • masuratori de tensiune c.a. si c.c. true-rms, la 1000 V
• • curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• • Masuratori de tensiune c.a. true-RMS pâna la 1000V
• • Masuratori de curent c.a. true-RMS la 2500 A


CALIBRATOR DE PRESIUNE FLUKE 719

• Best in class pressure measurement uncertainty of 0.025%
• Measure and source mA with best in class 0.015% accuracy
• 30 PSI and 100 PSI pressure ranges

 

ANALIZOR DE PUTERE DE PRECIZIE FLUKE NORMA 4000

• 1 to 3 power phases
• Bandwidth from dc to 3 MHz / 10 MHz
• FFT analysis, vector diagram, and Digital Oscilloscope
• Voltage, current and power harmonics measured up to the 40th harmonic

 

TESTER VIBRATII FLUKE 805

• measures overall vibration as well as specific variables like bearing condition and temperature
• calculate bearing condition and overall vibration
• Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz)
• Exportable data via USB
• Crest Factor+

 

MULTIMETRU DIGITAL PORTABIL CU DATA LOGGING 4.5 DIGIT FLUKE 289

• 4.5 digit large ¼ VGA display with white backlight
• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture
• Low input impedance function (LoZ)
• Motor winding and low ohm measurement range
• Low pass filter