Filtre de putere protectie radiatii RFI/ EMI curent redus scurgere pamant aplicatii mobile 6..100A ETS-Lindgren N242X

Cod: ETS-Lindgren N242X


 

Brosura produs PDF, 0.29 Mb

Descriere

  • Suitable for mobile installations
  • Extremely low current leakage
  • Over 100dB insertion loss from 150 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • Military field installations
  • Commercial installations using motor generator sets
  • Filtering of mains supplies where maximum safety is required
  • Under certain circumstances, the N242x filters may be used with earth leakage safety cut-outs (please consult the sales office for these types of applications)

 

Electrical Specifications

Part #

Current Max

Leakage Current Per Volt (N-E)

Voltage Max

# of Lines

Voltage Drop on Full Load in 250V 50/60/Hz System/Line

DC Resitance Per Line

N2420

6 A

2 mA

250 V

2

1 V

0.1 O

N2421

6 A

2 mA

440/250 V

4

1 V

0.1 O

N2422

32 A

8 mA

250 V

2

0.4 V

0.015 O

N2423

32 A

8 mA

440/250 V

4

0.4 V

0.015 O

N2424

63 A

8 mA

250 V

2

0.3 V

0.03 O

N2425

63 A

8 mA

440/250 V

4

0.3 V

0.03 O

N2426

100 A

10 mA

250 V

2

0.5 V

0.02 O

N2427

100 A

10 mA

440/250 V

4

0.5 V

0.02 O

 

Alte produse ETS-LINDGREN

ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2

 

ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

GENERATOR CAMP ELECTRIC ORIZONTAL/ VERTICAL 10 KHZ..30 MHZ ETS-LINDGREN 5502

• Generates vertical or horizontal electric field
• Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
• Fully Adjustable Height and Separation of Main Conductors
• Large Immunity Volume
• Chamber Supported

 

ANTENA HORN DESCHISA CUADRI-CREASTA 2..18 GHZ ETS-LINDGREN 3164-05

• Frequency Minimum 2 GHz
• Frequency Maximum 18 GHz
• Connectors SMA Female
• Cross Polarization Isolation >24 dB
• Impedance (Nominal) 50 ?
• Maximum Power 25 W
• Pattern Type directional
• Polarization dual linear

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HIBRID LOG-PERIODICA DE BANDA LARGA PENTRU MASURATORI EMC 26 MHZ..3 GHZ ETS-LINDGREN 3140B

• Frequency Minimum 26 MHz
• Frequency Maximum 3 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear
• Best EMC RI Performance

 

DIPOL SFERIC UNIVERSAL GENERARE RADIATII ELECTROMAGNETICE EMI ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

ANTENA DIPOL REZONANT 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA DIPOL LOG-PERIODIC 80 MHZ..2 GHZ ETS-LINDGREN 3144

• Frequency Minimum 80 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW

 

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz