Celula GTEM test, masura, incercari emisii radiatii electromagnetice si imunitate EMC ETS-Lindgren 5407

Cod: ETS-Lindgren 5407


 

Brosura produs PDF, 0.13 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f £1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

200 (500 W with optional blower) W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq £1.50:1
Characteristic Freq
£1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Two AC receptacles
  • ETS-Lindgren absorber material
  • Customer will need to provide manpower and specific tools
  • Three N-type connectors
  • One fiber optic penetration
  • Individually characterized with results of TDR and VSWR tests
  • Manual emissions correlation software (on request)
  • 5400 GTEM! Series manual
  • Shipped disassembled
  • Working supervisor for installation is provided. (Outside North America, call factory)
  • 7/16" DIN to type "N" adaptor
  • Primary door 27" W x 29.1" H clear opening (68.6 cm x 74.7 cm)
  • Mobile base with locking casters
  • One 20 amp, 2 line filter
 

Optiuni recomandate

  • Blank panel with frame
  • Illumination assembly
  • Manual EUT manipulator
  • Panel with connectors and frame
  • Shielded Window for primary door
  • Blank panel
  • Blank panel with connectors
  • Blower assembly
  • Three Position Ortho-Axis Pneumatic Manipulator (light duty)
 

Alte produse ETS-LINDGREN

SONDE MASURA CURENTI 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

FILTRE PROTECTIE RETEA MONOFAZATA APLICATII RFI/EMI PUTERE & CURENT INALT 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

ANTENA BUCLA MAGNETICA ECRANATA FRECVENTA JOASA 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE LINII TRANSMISIE RETELE ENERGIE ELECTRICA ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

TESTER CAMP MAGNETIC 30..2000 HZ ETS-LINDGREN HI-3624

• Isotropic Response
• True RMS Detection
• 100dB Dynamic Range
• Low Cost, True RMS Magnetic Field Measurements

 

ANTENA HORN PENTRU MASURATORI EMC 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

FILTRE DE PUTERE PROTECTIE RADIATII RFI/ EMI CURENT REDUS SCURGERE PAMANT APLICATII MOBILE 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

FILTRE EMI DE PUTERE RETELE MONOFAZATE APLICATII TEMPEST/ EMC 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked