Electrical Specifications model 6402

Amperes/ Meter/ Ampere

84.3

Gauge (AWG)

10

Gauss/Ampere

1.06

Number of Turns

36 per coil

Radius

30.5 cm

Total Inductance (H)

3.3 mH

Total Resistance ( )

0.5 ?

Type

Monaxial Helmholtz Coil

 

 

Electrical Specifications 6402M

Amperes/ Meter/ Ampere

11.14

Gauge (AWG)

20

Gauss/Ampere

0.14

Number of Turns

5 per coil

Radius

30.5 cm

Total Inductance (H)

87 wH

Total Resistance ( )

0.7 ?

Type

Monaxial Helmholtz Coil

 

 

Electrical Specifications 6404

Amperes/ Meter/ Ampere

65.73

Gauge (AWG)

10

Gauss/Ampere

0.826

Number of Turns

56 per coil

Radius

60.9 cm

Total Inductance (H)

19 mH

Total Resistance ( )

1.5

Type

Monaxial Helmholtz Coil

 

Alte produse ETS-LINDGREN

INCINTA ECRANATA TESTARE DISPOZITIVE WIRELESS ETS-LINDGREN 5247

• Roll-About Casters
• Portable RF Shielded Enclosure for OTA measurements
• >80 dB Typical RF Isolation
• RF Absorber Lined
• Dual Polarized Horn Antenna
• 700 MHz - 10 GHz Frequency Range
• Linear & Circular Polarization

 

TESTER EMF CAMP ELECTRIC & MAGNETIC RF CONFORM CU STANDARDE INDUSTRIALE 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

ANTENA ACTIVA BUCLA DE RECEPTIE 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

TESTER CAMP MAGNETIC 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

FILTRE PROTECTIE TEMPEST/ RFI/ EMI PENTRU TELECOMUNICATII ETS-LINDGREN N24X/ N29X

• Suitable for EMI, EMP and Tempest protection
• Tubular, flat-pack or modular design
• 100dB insertion loss
• New ISDN filters now available
• Matched to balanced 600 Ohm lines

 

ANTENA HORN PIRAMIDAL MULTI-OCTAVA LINIAR POLARIZATA 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear

 

TESTER MASURA ATENUARE RF SI ECRANARE ELECTROMAGNETICA 8..64 MHZ ETS-LINDGREN MF-130D

• Measurement frequencies: 8 MHz, 16 MHz, 32 MHz and 64 MHz
• Makes Shielding Attenuation
• MIL-STD-285 Measurements
• NSA 65-6 Measurements
• IEEE STD-299 Measurements
• EN 50147-1 Measurements
• Stores/Downloads up to 63
• Includes Windows® Compatible Easy-To-Use, Portable Software

 

ANTENA DIPOL MAGNETIC BUCLA REZONANTA MASURATORI RIPLU TELECOMUNICATII MOBILE SI INTERNET CTIA 440..2665 MHZ ETS-LINDGREN 3127

• Range of Frequencies to Cover Wireless Device Bands: 440...2665 MHz
• Designed for CTIA Ripple Test
• Meet CTIA +/- 0.1 dB Symmetry Requirement

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011