The paula phase detector is used for clear phase identification in earthed and shorted medium and high-voltage cables. With the help of the measurement procedure tried and tested over many years, paula delivers precise phase allocation without scope for interpretation and corresponds to the highest safety standards for tasks on and close to electric equipment.

 

Features:

  • Clear phase determination possible in cable lengths up to 40 km
  • Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)
  • Suitable for all switchgear constructions due to compact design of the signal injectors
  • Ready for operation for up to 2 weeks (standby mode)
 

Alte produse BAUR

BAUR SYSCOMPACT 2000 PORTABLE

• Fast and reliable
• Precise, dependable cable fault location
• High performance high voltage unit
• Integrated proven cable fault pre-location methods

 

BAUR PHG 70 TD PD / PHG 80 TD PD VLF TEST AND DIAGNOSTICS SYSTEM

• Compact, enclosed design in 19½ format
• Variable installation option with separate control and voltage unit
• Variable connection options to cable stations of different models

 

BAUR VIOLA AND VIOLA TD HIGH-VOLTAGE TEST AND DIAGNOSTICS DEVICE

• High performance and compact
• Precise and non-destructive determination of the cable condition
• Easy and quick test setup
• Automatic testing and diagnostic sequences

 

BAUR SSG 500 SURGE VOLTAGE GENERATOR

• 6 output voltages up to max. 16 kV available
• Electromagnetically actuated surge switch
• Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)
• Automatic discharge unit

 

BAUR PHG 70 / PHG 80 PORTABLE VLF TEST SYSTEM

• 3 voltage shapes in one device: VLF truesinus®, VLF square wave and DC voltage
• For medium-voltage cables of up to 50 kV operating voltage
• Cable testing, fault conditioning, cable sheath testing

 

BAUR ATG 2 BURN DOWN TRANSFORMER

• Portable device for changing the fault resistance
• Useful for cables that are difficult to access
• Proven methods for complicated faults
• Independent current and voltage control on each burning level

 

BAUR DPA 75 C OIL BREAKDOWN VOLTAGE TESTER

• Compact and robust device for portable use onsite
• Test voltages from 0 to 75 kVrms
• Repeatable breakdown measurements in mineral, silicone and plant oils
• Reliable measurement results due to its short switch-off time (< 10 ½s)

 

BAUR DTL C OIL BREAKDOWN VOLTAGE TESTER

• Fully automatic dissipation factor measurement
• Pre-programmed standards
• Maximum accuracy

 

BAUR TG 20/50 AUDIO FREQUENCY TRANSMITTER

• Automatic or manual impedance adjustment
• Charging unit and rechargeable battery integrated; battery or mains operation
• Continuous or cyclical output
• Two output frequencies selectable

 

BAUR SHIRLA CABLE SHEATH TESTING AND FAULT LOCATION SYSTEM

• Cable and cable sheath testing up to 10 kVC
• Resistance measurement
• Cable and cable sheath fault pre-location with precision measuring bridge
• Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation