The paula phase detector is used for clear phase identification in earthed and shorted medium and high-voltage cables. With the help of the measurement procedure tried and tested over many years, paula delivers precise phase allocation without scope for interpretation and corresponds to the highest safety standards for tasks on and close to electric equipment.

 

Features:

  • Clear phase determination possible in cable lengths up to 40 km
  • Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)
  • Suitable for all switchgear constructions due to compact design of the signal injectors
  • Ready for operation for up to 2 weeks (standby mode)
 

Alte produse BAUR

BAUR ATG 6000 BURN DOWN TRANSFORMER

• Proven methodes for cable faults that are difficult to locate
• Useful for cables that are difficult to access
• Robust construction for reliable functions
• Independent current and voltage control on each burning level

 

BAUR IRG 2000 TIME DOMAIN REFLECTOMETER

• Easy and quick cable fault location
• Light, compact and manageable
• Main unit for the tried-and-tested pre-location method
• Ideal for integration in measurement systems

 

BAUR CL 20 CABLE LOCATOR

• Fast and exact location of position and laying depth of cables
• Intuitive operation ½ no special measurement knowledge required
• Lightweight and manageable

 

BAUR SYSCOMPACT 2000 PORTABLE

• Fast and reliable
• Precise, dependable cable fault location
• High performance high voltage unit
• Integrated proven cable fault pre-location methods

 

BAUR SHIRLA CABLE SHEATH TESTING AND FAULT LOCATION SYSTEM

• Cable and cable sheath testing up to 10 kVC
• Resistance measurement
• Cable and cable sheath fault pre-location with precision measuring bridge
• Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation

 

BAUR PGK 110 HB HIGH-VOLTAGE TEST DEVICE

• Testing of medium- and high-voltage cables
• DC voltage testing of up to 110 kV output voltage with positive or negative polarity
• AC voltage testing - up to 80 kV for switchgear, busbars and insulating elements
• Easy-to-maintain 2-piece design

 

BAUR PGK 50E / PGK 80E DC HIGH-VOLTAGE TEST DEVICE

• Continuous adjustable output voltage
• The voltage measurement is done directly at the high voltage output
• Timer of 1-30 min
• Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

 

BAUR PHG 70 TD PD / PHG 80 TD PD VLF TEST AND DIAGNOSTICS SYSTEM

• Compact, enclosed design in 19½ format
• Variable installation option with separate control and voltage unit
• Variable connection options to cable stations of different models

 

BAUR DTA 100 C OIL BREAKDOWN VOLTAGE TESTER

• Fully automatic measurement sequence
• Suitable for mineral or silicone oils and easther liquids
• Reliable, reproducible measurement results using the latest measument technology
• Designed for daily countinous operations in laboratories

 

BAUR DTA IL OIL BREAKDOWN VOLTAGE TESTER

• Inline insulating oil testing in oil preparation systems
• Quality assurance during production processes
• Improved, easy oil sample handling
• Integration in existing production process control possible