YOKOGAWA GS820 Multi Channel Source Measure Unit

Code: YOKOGAWA GS820 Multi Channel Source Measure Unit


 

Datasheet PDF, 2.97 Mb

Description

The GS820 is equipped with two analog channels with each channel consisting of a constant voltage source VS, a constant current source IS, a voltmeter VM, and an ammeter IM. The two source measure channels are isolated.

 

Four-quadrant operation consisting of source operation (current source) and sink operation (current sink) is available with ranges up to 7 V and 3.2 A or 18 V and 1.2 A. The output and measurement resolutions are 5.5 digits.

 

Features:

  • 1 pA resolution at extremely small current range 200 nA
  • Generate arbitrary waveforms consisting of up to 100,000 points at 100 µs intervals
  • Channel expansion through master-slave synchronization link
  • Fast test speeds
  • 16-bit digital I/O (model 765602/12)
 

More products YOKOGAWA

YOKOGAWA AQ6150 SERIES OPTICAL WAVELENGTH METER

• High wavelength accuracy of ±0.3pm
• Cope with modulated light and optical filter measurement
• Simultaneous measurement of up to 1024 wavelengths
• Increase throughput with high speed measurement

 

YOKOGAWA - PROCESS CALIBRATOR CA300 SERIES CA310 CA320 CA330

• Basic Accuracy: 0.015% (Source&Meas. accuracy of Voltage mA)
• Simultaneously supplies 24V loop power and measure output signal with high accuracy
• Sub display displays span% of the source value
• HART/BRAIN comm. resistance (250O) embedded

 

YOKOGAWA AQ6360 TELECOM PRODUCTION OPTICAL SPECTRUM ANALYZER 1200 - 1650 NM

• Wavelength range: 1200 to 1650 nm
• Wavelength resolution: 0.1 to 2 nm
• High wavelength accuracy: ±0.02 nm
• High dynamic range: 55 dB
• Wide measurement range: +20 to -80 dBm

 

YOKOGAWA - LEAKAGE CURRENT TESTER 322610 (ANALOG)

• ± 2.5% full scale accuracy
• 100µA full scale value
• Shockproof indicator using taut band movement
• Built-in overload protection circuit
• Handy and easy to carry

 

YOKOGAWA - AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA - PX8000 PRECISION POWER SCOPE

• Provides simultaneous voltage and current multiplication to give real-time power sampling.
• Trend measurements between waveforms can be calculated by mathematical functions (up to four million points).
• Supports the capture of power parameters over specific periods of time through the definition of start and stop "cursors".
• An always-active History function automatically records up to 1,000 historical waveforms.

 

YOKOGAWA AQ2212 FRAME CONTROLLER (9 SLOTS)

• Easy-to-view color display
• USB port for data storage
• Measurement module "hot-swapping" capability
• Remote monitoring and measurement through a LAN

 

YOKOGAWA - DIGITAL MANOMETERS MT210 MT210F

• ±0.01%, with a maximum allowable input of 500 kPa (130 kPa-range model)
• Offering low differential pressure of 1 kPa to a high gauge pressure of 3000 kPa
• Normal speed, medium speed, and high speed (MT210F series)

 

YOKOGAWA AQ6375B LONG WAVELENGTH OPTICAL SPECTRUM ANALYZER 1200 - 2400 NM

• Long wavelength range: 1200 to 2400 nm
• Gas purging ports to reduce water vapor effects
• Built-In cut filter for high order diffracted light
• Double Speed Mode to further enhance fast measurement speed

 

YOKOGAWA - MINI-MANOMETER MT10

• High reliability (with silicon resonant sensor)
• Compact
• Accuracy: ± (0.04% of rdg + 0.03% of F.S.) (130 kPa model)