YOKOGAWA -lamp-on Tester CL155 (AC, True RMS, 2000A)

Code: YOKOGAWA CL155


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • True RMS display
  • 54mm in diameter of measurable conductor
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. HI 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

2.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

?.5% rdg ± 0.5mV (50/60Hz)
?.5% rdg ± 0.5mV (40~1kHz)

Method of detection

True RMS

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2.0% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W)x247(H)x49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011) User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

More products YOKOGAWA

YOKOGAWA AQ1300 SERIES 1G/10G ETHERNET MULTI FIELD TESTER

• Optical and electrical measurement ports for 10M to 1G (AQ1301) and 10M to 10G (AQ1300) are available
• Built-in Optical power meter (factory-installed option for the AQ1300)
• Equipped with a variety of test functions to evaluate Ethernet performance, such as a throughput test, latency measurement, bit error rate test, and PING test.

 

YOKOGAWA - WT500 MID-RANGE POWER ANALYZER

• Current range: 0.5 to 40 A
• Voltage range: 15 to 1000 V
• Basic Power Accuracy: 0.1%
• frequency range: DC 0.5 Hz to 100 kHz

 

YOKOGAWA CLAMP-ON TESTER CL150 (ACA, ACV, DCV, OHM, 2000A)

• AC/DC voltage and resistance measurements
• 54mm in diameter of measurable conductor
• Mean value display
• DC output function
• Data hold function

 

YOKOGAWA - DIGITAL MANOMETER MT220

• Measurement with DCV and DCA
• 24 V DC output
• Percent reading
• Error reading
• Measurement data memory

 

YOKOGAWA - AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA DIGITAL MULTIMETER TY710

• Conforms to safety standards EN61010-1 1000V CAT., 600V CAT.
• Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
• Operating temperature range -20 to +55C
• Storage temperature range -40 to +70
• Closed Case Calibration

 

YOKOGAWA GS200 DC VOLTAGE / CURRENT SOURCE

• Voltage source up to ±32 V and current source up to ±200 mA
• 51/2-digit, 120000-count output resolution
• Voltage and current simple monitoring feature (optional)
• Programmable output up to 10,000 points
• Built-in USB mass storage device
• Channel expansion through synchronous operation

 

YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR

• Frequency range: Sine wave 0.01 µHz to 30 MHz
• Amplitude resolution: 16 bits
• Sampling rate: 120 MS/s
• Output: 0 to 20 Volts, peak-to-peak

 

YOKOGAWA LS3300 AC POWER CALIBRATOR

• High Accuracy
• Phase Accuracy
• High Stability
• Wide generation range
• Single to three phase power calibration

 

YOKOGAWA GS820 MULTI CHANNEL SOURCE MEASURE UNIT

• DC voltage/current reference, pulse voltage/current source
• V-I curve trace, semiconductor parametric test
• Programmable arbitrary waveform generation
• Electric load, resistance measurement
• Production test