YOKOGAWA Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A)

Code: YOKOGAWA CL150


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

1.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

.5?% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz)

Method of detection

Mean Value

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W) x 247(H) x 49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

More products YOKOGAWA

YOKOGAWA DIGITAL MULTIMETER TY520

• High Precision
• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety

 

YOKOGAWA AQ1300 SERIES 1G/10G ETHERNET MULTI FIELD TESTER

• Optical and electrical measurement ports for 10M to 1G (AQ1301) and 10M to 10G (AQ1300) are available
• Built-in Optical power meter (factory-installed option for the AQ1300)
• Equipped with a variety of test functions to evaluate Ethernet performance, such as a throughput test, latency measurement, bit error rate test, and PING test.

 

YOKOGAWA GS200 DC VOLTAGE / CURRENT SOURCE

• Voltage source up to ±32 V and current source up to ±200 mA
• 51/2-digit, 120000-count output resolution
• Voltage and current simple monitoring feature (optional)
• Programmable output up to 10,000 points
• Built-in USB mass storage device
• Channel expansion through synchronous operation

 

YOKOGAWA DIGITAL MULTIMETER TY720

• True RMS measurement
• New Functions for Electronic and Industrial Use
• Simultaneous measurement and display of DC and AC
• Switchable RMS/MEAN detection

 

YOKOGAWA - WT3000E PRECISION POWER ANALYZER

• Basic power accuracy: 0.01% of reading
• Both 2 A and 30 A input elements can be installed in a single unit
• Good readability: 8.4-inch LCD and the range indicator LEDs
• Simultaneous measurement with 2 units (Up to 8 power input elements)
• Store function: 50 ms data storing interval

 

YOKOGAWA - AQ6376 THREE MICRON OPTICAL SPECTRUM ANALYZER

• Long wavelength range: 1500 to 3400 nm
• Gas purging ports to reduce water vapor effects
• Built-In cut filter for high order diffracted light
• Double Speed Mode to further enhance fast measurement speed

 

YOKOGAWA LOW PRESSURE CALIBRATOR CA700

• IP54 dustproof and water proof case for harsh environments
• 4-20mA step function for signal generation
• 20mA Simulator to carry out loop test.
• Two-wire Transmitter Loop Check

 

YOKOGAWA CLAMP-ON POWER METER CW10 (SINGLE-PHASE)

• AC / DC Power up to 600 kW, AC / DC Voltage max. 1000 V, AC / DC Current max. 600 A
• True RMS for AC .
• Harmonics 1st to 25th order
• Power fluctuation using the ACA Inrush and Peak hold functions.
• Frequency, Resistance, Continuity, Diode check, Power factor.

 

YOKOGAWA - AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA DIGITAL MULTIMETER TY530

• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety
• Conforms to safety standards EN61010-1, 1000V CAT III, 600V CAT IV