YOKOGAWA Clamp-on Tester CL150 (ACA, ACV, DCV, OHM, 2000A)

Code: YOKOGAWA CL150


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

1.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

.5?% rdg ± 0.5mV (50/60Hz)
.5% rdg ± 0.5mV (40~1kHz)

Method of detection

Mean Value

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W) x 247(H) x 49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User's manual (IM CL150), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

More products YOKOGAWA

YOKOGAWA AQ7280 MODULAR OPTICAL TIME DOMAIN REFLECTOMETER

• Reliability: Robust design for operating under harsh field conditions. Proven operating system assuring stability, prompt response, and superior protection against software virus attacks.
• Ease-Of-Use: Dual operation mode by multi-touch touchscreen and hard-key buttons. Fully automatic measurement and easy-to-read analysis reports through new software applications.
• Speed: Lightning startup time. Multi-tasking operation to enhance productivity. Immediate reporting via wireless connectivity.

 

YOKOGAWA - MINI-MANOMETER MT10

• High reliability (with silicon resonant sensor)
• Compact
• Accuracy: ± (0.04% of rdg + 0.03% of F.S.) (130 kPa model)

 

YOKOGAWA DIGITAL MULTIMETER TY520

• High Precision
• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety

 

YOKOGAWA LS3300 AC POWER CALIBRATOR

• High Accuracy
• Phase Accuracy
• High Stability
• Wide generation range
• Single to three phase power calibration

 

YOKOGAWA 2560A HIGH VOLTAGE AND HIGH CURRENT PRECISION DC CALIBRATOR

• Wide output range of voltage and current generation
• Dials and switches for each digit and function
• High accuracy, stability, and resolution
• Various effective functions for analog meters calibration.

 

YOKOGAWA EARTH TESTER EY200 (DIGITAL)

• 2P Test leads (for simplified measurement) has a structure that both the safety alligator clip and the test probe are available
• Warns when earth resistance of auxiliary earth spikes exceeds the permissible limit
• Convenient carrying soft bag for accessories etc.
• 3-Pole Earth Resistance Measurement (Precise Measurement)

 

YOKOGAWA - AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA - PX8000 PRECISION POWER SCOPE

• Provides simultaneous voltage and current multiplication to give real-time power sampling.
• Trend measurements between waveforms can be calculated by mathematical functions (up to four million points).
• Supports the capture of power parameters over specific periods of time through the definition of start and stop "cursors".
• An always-active History function automatically records up to 1,000 historical waveforms.

 

YOKOGAWA AQ6150 SERIES OPTICAL WAVELENGTH METER

• High wavelength accuracy of ±0.3pm
• Cope with modulated light and optical filter measurement
• Simultaneous measurement of up to 1024 wavelengths
• Increase throughput with high speed measurement

 

YOKOGAWA CLAMP-ON POWER METER CW10 (SINGLE-PHASE)

• AC / DC Power up to 600 kW, AC / DC Voltage max. 1000 V, AC / DC Current max. 600 A
• True RMS for AC .
• Harmonics 1st to 25th order
• Power fluctuation using the ACA Inrush and Peak hold functions.
• Frequency, Resistance, Continuity, Diode check, Power factor.