Three-Channel Vibration Analyzer for workers protection Delta Ohm HD2070

Code: Delta Ohm HD2070


 

Datasheet PDF, 0.82 Mb
                 

Description

The HD2070 is a portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously. The instrument measures all parameters required by current regulations concerning workers protection from vibration related risks and is able to measure vibrations transmitted to both hand-arm and whole body. It has been designed combining simplicity of use with maximum flexibility and the possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement. 

 

The HD2070 vibration analyzer conforms to the following standards:

• ISO 8041:2005 "Human response to vibration - Measuring instrumentation"

• ISO 5349-1:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - General requirements"

• ISO 5349-2:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Practical guidance for measurement at the workplace"

• ISO 2631-1:1997 "Mechanical vibration and shock - Evaluation of human exposure to whole body vibration - General requirements"

• ISO 2631-2:1989 "Evaluation of human exposure to whole body vibration - Continuous and shock-induced vibrations in buildings (1 to 80 Hz)"

• IEC 61260:1995 "Electro- acoustics - Octave band and fractional-octave band filters" (option HD2070.O1)

 

 

Main features

• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard.

• The HD2070 detects accelerations on three axes with integrated amplifying electronics (IEPE or equivalent type); it is possible to connect three singleaxes or one tri-axial accelerometer to the instrument. Accelerometers with integrate electronics allow to achieve low impedance and low noise connections between the accelerometer and the instrument, decreasing the probability to get wrong or altered measurements because of interferences or electromagnetic disturbances.

• The HD2070 analyzes the signals coming from the accelerometer and makes calculations simultaneously on three axes; it calculates the weighted acceleration values as well as the octave or third octave spectra (with option HD2070.O1). Acceleration, velocity or displacement values can be shown for each frequency band. Frequency weightings can be freely chosen according to the specific application.

• Together with values of instantaneous and mean acceleration, the analyzer calculates in addition peak levels, vibration dose (VDV), crest factors and performs statistical analysis (option HD2070.O2).

• As statistical analyzer, the HD2070 calculates, with option HD2070.O2, the probability distribution of a measurement parameter in 1dB classes. Both the probability distribution and the percentile levels from L1 to L99 are available as graphs.

• A versatile data logging function stores multiple profiles and spectra using either the internal memory of 8MB or memory card (MMC or SD cards up to 2GB). Each record can be documented with a voice comment. In addition, the HD2070 can be used as an audio recorder, as a further opportunity to document the measures.

• With the option HD2070.O3 you can add to the profiles also the signals provided by accelerometers, recording the digital samples directly. When the stored data are analyzed, it is useful to examine the accelerometer signals to verify the absence of artefacts such as, for example, those associated with the phenomenon of DC-shift.

• The "Navigator" program available in the analyzer allows to examine logged measurements and to hear vocal comments.

• For a quick setup of the instrument it is possible to store up to nine setup, user-customized according to specific applications. The desired setup is easily identified by the associated title.

• The calibration can be performed using either the calibration data of the accelerometers with a vibration generator. The last 120 calibrations performed are recorded in a file and stored in a protected and reserved area of the permanent memory of the instrument. The program interface Noise Studio automatically adds the file supplied with the calibration measurements during the downloading of data into the PC memory.

• HD2070 can be completely controlled by a PC, via RS232 and USB serial interfaces, using a special communication protocol.

 

More products SENSECA

MULTIFUNCTION DATALOOGER WITH MICROCLIMATE ANALYSIS DELTA OHM HD32.1

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head...

 

PORTABLE CLASS I INTEGRATING SOUND LEVEL METER WITH SPECTRUM ANALYSIS ANS STATISTICS DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz

 

MANOMETER-THERMOMETER DIGITAL HANDHELD DELTA OHM HD2124.1 HD2124.2

• Manometer-Thermometer with two inputs for SICRAM module PP471 to connect probes TP704 and TP705 series.
• Temperature measurement with Pt100 probe complete with SICRAM module measuring range 200°C +650°C.
• Datalogger which stores the maximum, minimum, average value and can store up to 32,000 couples of samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD, PEAK and auto power off which can be disabled,
• IP 67 protection degree.

 

ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

DISSOLVED OXIGEN TESTER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2109.1 HD2109.2

• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 18,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

MANOMETERS-THERMOMETERS DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

INTEGRATING SOUND LEVEL METER CLASS I OR CLASS II WITH SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC

• integrating portable sound level meter performing statistical analysis
• maximum low cost and simplicity of use
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 dated 2002, IEC 60651 and IEC 60804
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis

 

METEO DATALOGGER WITH DATA ACQUISITION AND RECORDING DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers