Sound Level Calibrator with Audio Signal Generator for acoustic calibrations Class I/II Delta Ohm HD9101 HD9102

Code: Delta Ohm HD9101 HD9102


 

Datasheet PDF, 0.27 Mb

Description

APPLICATION FIELD
The generator noise level 9101/HD HD 9102 is a portable, battery-powered sound source, suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations. And ‘possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1 ("Measurement Microphones, Part 1: Specifications for Laboratory Standard Microphones") and IEC 61094-4 ("Measurement Microphones. Part 4: Specifications for working Standard Microphones)

 

 

TECHNICAL SPECIFICATIONS
The calibrator HD9101 satisfies Class 1 specifications according to the standard IEC 60942-1988 and complies with the requirements of the standard ANSI S1.40-1984.

Advantages of the acoustic soundlevel calibrators HD 9101 / HD 9102 are:
- With the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting (LIN, A, B, ...), without introducing correction factors.
- The sound pressure level generated is independent of atmospheric pressure is therefore not necessary to correct the value function of atmospheric pressure.
- The calibrator 9101/HD HD 9102 can be conveniently used in both laboratory and field.
- Ease of use allows the use even by unskilled personnel.
 

More products SENSECA

PORTABLE CLASS I INTEGRATING SOUND LEVEL METER WITH SPECTRUM ANALYSIS ANS STATISTICS DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz

 

PORTABLE PH-METER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

THERMO HYGROMETER DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

PORTABLE LABORATORY TURBIDITY-METER FOR LPROCESS IQUIDS, DRINKING WATER, WASTE WATER DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

DUAL INPUT THERMOMETER DELTA OHM HD2178.1 HD2178.2

• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N
• large display
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

8-16 CHANNEL TEMPERATURE DATALOGGER DELTA OHM HD32.7 HD32.8.8 HD32.8.16

• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES
• HD32.8.8/ HD32.8.16 Rugged data logger with 8/16 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes
• Unit of measurement °C, °F, °K configurable.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.