Net Radiometer for Ultraviolet to Infrared Solar Radiation measurement Delta Ohm LP NET07

Code: Delta Ohm LP NET07


 

Datasheet PDF, 0.25 Mb

Description

LP NET 07 measures the net radiation across a surface, from near ultraviolet to

far infrared. The Net radiation is defined as the difference between the radiation

that reaches the upper surface and the irradiation on the lower surface of the net

radiometer. The surface of the upper receiver measures the direct solar radiation

plus the diffuse one and the radiation at longer wavelengths emitted from

the sky (clouds), while the lower receiving area measures the solar radiation

reflected from the ground (albedo) and the radiation length wavelengths emitted

from the earth.

The instrument is designed and constructed to be used outdoors in any weather

conditions.

 

More products SENSECA

RAIN DETECTOR AND ATHMOSPHERICAL PRECIPITATION DELTA OHM HD2013.2

• rain detector based on the capacity principle
• The instrument is equipped with three different outputs: a "Rain ON/OFF" output
• detects whether it is raining/ snowing (ON) or not (OFF), also used to control a relay coil or similar devices
• can be used either as a separate device, or connected to a data logger system

 

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

CONDUCTIVIMETER-THERMOMETER FOR CONDUCTIVITY, LIQUID RESISTIVITY, DISSOLVED SOLIDS, SALINITY, TEMPERATURE DELTA OHM HD2306.0

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

ANEMOMETER-THERMOMETER AIR SPEED MEASUREMENT DELTA OHM HD2303.0

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PHOTOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR ILLUMINANCE DELTA OHM LP PHOT02

• Outdoor photometric probe for measuring ILLUMINANCE (0...150 Klux),
• CIE photopic filter,
• diffuser for cosine correction.
• mVdc output for klux.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors.

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

MINI-DATALOGGER FOR TEMPERATURE AND RELATIVE HUMIDITY DELTA OHM HD206 HD226 HD207 HD227

• TEMPERATURE and RELATIVE HUMIDITY mini data logger with/no display
• Selectable storage interval 1-5-10-15-30 sec/min, 1 hour.
• Storage of 120,000 reading per channel,
• 8mm 3 ½ digit LCD display.
• IP54 protection degree.

 

PORTABLE LABORATORY TURBIDITY-METER FOR LPROCESS IQUIDS, DRINKING WATER, WASTE WATER DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

MICRO MANOMETER-THERMOMETER DELTA OHM HD2114P HD2134P

• Micromanometer-Thermometer for air speed and flow rate measurement by means of Pitot tubes
• full scale 20mbar for speed measurements from 2...55m/s.
• Temperature measurement by K type thermocouple.
• Datalogger which stores the maximum, minimum, average value and can store up to 36,000 couples of samples.
• RS232C/ USB output for data transfer in real time to a PC or printer