Integrating Sound Level Meter Class I / Class II with Datalogging, Spectral Analysis & Statistics Delta Ohm HD2010UC/A

Code: Delta Ohm HD2010UC/A


 

Datasheet PDF, 0.46 Mb
       

Description

HD2010UC/A is a portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses The instrument has been designed by combining maximum flexibility and simplicity. Attention has been paid to the possibility of adjusting the instrument so to comply with the changes in the rules about noise and to the necessity of comply with the current and future requests of the
users. It is possible to add options to the HD2010UC/A so to extend its applications; the user can update the firmware directly by means of the Noise Studio programme supplied with the instrument.
Several kits are available, ready to use!

Technical regulations:

• Class 1 or 2 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.N.RI.M. No. 07-0124-02), IEC 60651 and IEC 60804.
• Class 1 octave and third octave filters according to IEC 61260.

Applications:
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,
• Statistical analysis with the calculation of 3 percentile levels and optional full statistical analysis,
• Identification of impulsive noise,
• Measurements in workplaces,
• Selection of personal protective equipment (SNR, HML, and OBM methods),
• Sound insulation and reclamation,
• Production quality control,
• Measurement of machine noise,
• Optional architectural acoustics and building measurements.


Sound level meter Class 1 Kits:

HD2010UC/A kit1: consists of HD2010UC/A class 1 sound level meter , HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial
RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit1/E: version for outdoor measurements, it consists of HD2010UC/A class 1 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated  preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit1/IE: version for indoor and outdoor measurements, it consists of HD2010UC/A class 1 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated
preamplifier, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

 

 

HD2010UC/A is a portable integrating class 2 sound level meter, with data logging function, suitable for performing statistical and spectral analyses The instrument has been designed by combining maximum flexibility and simplicity. Attention has been paid to the possibility of adjusting the instrument so to comply with the changes in the rules about noise and to the necessity of comply with the current and future requests of the
users. It is possible to add options to the HD2010UC/A so to extend its applications; the user can update the firmware directly by means of the Noise Studio programme supplied with the instrument.
Several kits are available, ready to use!

Technical regulations:

• Class 2 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.N.RI.M. No. 07-0124-02), IEC 60651 and IEC 60804.
• Class 2 octave and third octave filters according to IEC 61260.

Applications:
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,
• Statistical analysis with the calculation of 3 percentile levels and optional full statistical analysis,
• Identification of impulsive noise,
• Measurements in workplaces,
• Selection of personal protective equipment (SNR, HML, and OBM methods),
• Sound insulation and reclamation,
• Production quality control,
• Measurement of machine noise,
• Optional architectural acoustics and building measurements.


Sound level meter Class 2 Kits:

HD2010UC/A kit2: consists of HD2010UC/A class 2 sound level meter , HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial
RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit2/E: version for outdoor measurements, it consists of HD2010UC/A class 2 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated  preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit2/IE: version for indoor and outdoor measurements, it consists of HD2010UC/A class 2 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated
preamplifier, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

 

Standard accessories

 

 

More products SENSECA

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

MONO-AXIAL ACCELEROMETER AND TRIAXIAL ACCELEROMETER ICP MECHANICAL VIBRATIONS DELTA OHM

• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system
• HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system
• HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body
• HD356A22: tri-axial accelerometer for general application
• HD352C34: mono-axial accelerometer for general application
• HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level

 

LABORATORY TESTER FOR ELECTROCHEMICAL PARAMETERS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

CONDUCTIVIMETER-THERMOMETER FOR CONDUCTIVITY, LIQUID RESISTIVITY, DISSOLVED SOLIDS, SALINITY, TEMPERATURE DELTA OHM HD2306.0

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PLUVIOMETER RAIN GAUGE FOR ATMOSFERIC PRECIPITATION DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

FOUR-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION RISK DELTA OHM HD2030

• portable vibration analyzer performing spectral and statistical analysis on four channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• satisfies the specifications of standards ISO 8041:2005, ISO 5349-1:2001 (handarm vibrations)
• ISO 2631-1, 2 and 4 1997 (whole-body vibrations)
• detects accelerations on four axes through two accelerometers with integrated amplifying electronics

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.