Code: Delta Ohm HD32.1
Description
Technical data HD32.1:
Thanks to specific software: Moderate environments, Hot environments, Cold environments and Discomfort, as well as specific probes, the instrument can perform the following measurements:
• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head (1,7m subject standing; 1,1m subject sitting).
• Air temperature at the height of the abdomen (1,1 m subject standing; 0,6m subject sitting).
• Air temperature at the height of the ankles (0,1 m).
• Temperature at the floor level.
• Net radiation temperature.
• Net radiation.
• Radiant temperature asymmetry.
• Illuminance, luminance, PAR, irradiance, CO and CO2.
According to measurements performed, HD32.1, together with its specific software, calculates the following parameters:
• tr : Mean radiant temperature
• PMV : Predicted Mean Vote
• PPD : Predicted Percentage Dissatisfied
• DR : Draught Rating
• tO : Operative temperature
• IS : Scharlau Index
• DI : Thom Index
• THI : Thermohygrometric Index
• RSI : Relative Strain Index
• SSI : New Summer Simmer Index
• HI : Heat Index
• H : Humidex Index
• Teq : Equivalent Temperature Index
To compute the calculation of these indexes, temperature and relative humidity of the air have to be detected and the measured values to be inserted in the table "Discomfort indexes".
• WBGTIndoor : Wet bulb Globe temperature
• WBGTOutdoor : Wet bulb Globe temperature in the presence of radiation
• SWp : Sweat rate
• Ep : Predicted evaporative heat flow
• PHS : Tre - Water loss - Dlim tre - Dlimloss50 - Dlimloss95
• IREQ : Required clothing insulation
• DLE : Duration Limit Exposure
• RT : Recovery time
• WCI : Wind chill index
• PDv : Percentage Dissatisfied due to vertical temperature difference (head-ankles)
• PDf : Percentage Dissatisfied due to floor temperature
• PD? : Percentage Dissatisfied due to radiant asymmetry
• FLD : Average Day Light Factor
The calculation of the FLD index requires light measurement (photometric probe LP-471PHOT). Requires program "HD32.1 prog. C"
HD32.1 Kit basic: It is composed of HD32.1 instrument, A operating program:
Analysis of the Microclimate, four 1.5V alkaline batteries size C-BABY, instruction manual. The instrument includes atmospheric pressure sensor.
DeltaLog10 Basic moderate environments Software (for operating systems from Windows 98 to Windows7).
More products SENSECA
|
8-16 CHANNEL TEMPERATURE DATALOGGER DELTA OHM HD32.7 HD32.8.8 HD32.8.16
• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES |
|
MINI-DATALOGGER FOR TEMPERATURE AND RELATIVE HUMIDITY DELTA OHM HD206 HD226 HD207 HD227
• TEMPERATURE and RELATIVE HUMIDITY mini data logger with/no display |
|
LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2
• Bench-top pHmeter-Conductivity meter-Thermometer |
|
FOUR-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION RISK DELTA OHM HD2030
• portable vibration analyzer performing spectral and statistical analysis on four channels simultaneously |
|
INTEGRATING SOUND LEVEL METER CLASS I OR CLASS II WITH SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC
• integrating portable sound level meter performing statistical analysis |
|
DUAL INPUT THERMOMETER DELTA OHM HD2178.1 HD2178.2
• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N |
|
HVACR DATALOGGER FOR AIR SPEED, FLOW, PRESSURE, TEMPERATURE DELTA OHM DO2003
• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes, |
|
SILICON PHOTODIODE PYRANOMETER WITH GLOBAL SOLAR RADIATION MEASUREMENT FOR PHOTOVOLTAIC PANELS DELTA OHM LP SILICON-PYRA04
• LP Silicon-PYRA 04. pyranometer |
|
MULTIFUNCTION DATALOOGER WITH MICROCLIMATE ANALYSIS DELTA OHM HD32.1
• Globe temperature |
|
MANOMETERS-THERMOMETERS DELTA OHM HD2114 HD2134 HD2164
• portable instruments with a large LCD display |