Multifunction Datalooger with Microclimate analysis Delta Ohm HD32.1

Code: Delta Ohm HD32.1


 

Datasheet PDF, 1.55 Mb

Description

Technical data HD32.1:

Thanks to specific software: Moderate environments, Hot environments, Cold environments and Discomfort, as well as specific probes, the instrument can perform the following measurements:

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head (1,7m subject standing; 1,1m subject sitting).
• Air temperature at the height of the abdomen (1,1 m subject standing; 0,6m subject sitting).
• Air temperature at the height of the ankles (0,1 m).
• Temperature at the floor level.
• Net radiation temperature.
• Net radiation.
• Radiant temperature asymmetry.
• Illuminance, luminance, PAR, irradiance, CO and CO2.

According to measurements performed, HD32.1, together with its specific software, calculates the following parameters:
• tr : Mean radiant temperature
• PMV : Predicted Mean Vote
• PPD : Predicted Percentage Dissatisfied
• DR : Draught Rating
• tO : Operative temperature
• IS : Scharlau Index
• DI : Thom Index
• THI : Thermohygrometric Index
• RSI : Relative Strain Index
• SSI : New Summer Simmer Index
• HI : Heat Index
• H : Humidex Index
• Teq : Equivalent Temperature Index


To compute the calculation of these indexes, temperature and relative humidity of the air have to be detected and the measured values to be inserted in the table "Discomfort indexes".
• WBGTIndoor : Wet bulb Globe temperature
• WBGTOutdoor : Wet bulb Globe temperature in the presence of radiation
• SWp : Sweat rate
• Ep : Predicted evaporative heat flow
• PHS : Tre - Water loss - Dlim tre - Dlimloss50 - Dlimloss95
• IREQ : Required clothing insulation
• DLE : Duration Limit Exposure
• RT : Recovery time
• WCI : Wind chill index
• PDv : Percentage Dissatisfied due to vertical temperature difference (head-ankles)
• PDf : Percentage Dissatisfied due to floor temperature
• PD? : Percentage Dissatisfied due to radiant asymmetry
• FLD : Average Day Light Factor
The calculation of the FLD index requires light measurement (photometric probe LP-471PHOT). Requires program "HD32.1 prog. C"


HD32.1 Kit basic: It is composed of HD32.1 instrument, A operating program: 
Analysis of the Microclimate, four 1.5V alkaline batteries size C-BABY, instruction manual. The instrument includes atmospheric pressure sensor.
DeltaLog10 Basic moderate environments Software (for operating systems from Windows 98 to Windows7).

 

 

More products SENSECA

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

PORTABLE CLASS I INTEGRATING SOUND LEVEL METER WITH SPECTRUM ANALYSIS ANS STATISTICS DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz

 

NET RADIOMETER FOR ULTRAVIOLET TO INFRARED SOLAR RADIATION MEASUREMENT DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.

 

ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

HANDHELD DIGITAL THERMOMETER PT100 SENSOR -200°C +650°C DELTA OHM HD2307.0

• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module,
• measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• Functions: REL, HOLD and auto-power-off which can be disabled
• IP 67 protection degree

 

NET RADIOMETER WITH 4-COMPONENTS FOR SOLAR RADIATION MEASUREMENTS DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

HVACR DATALOGGER FOR AIR SPEED, FLOW, PRESSURE, TEMPERATURE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


THERMO HYGROMETER DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66