Code: Delta Ohm HD2013.2
Description
The HD2013.2 is a rain detector based on the capacity principle. The capacity
value of the sensitive element, on an alumina rest, changes according to the
surface dampened by raindrops. An integrated heater keeps it dry, evaporates
water and prevents false signals caused by fog or dew. The heater also
activates at low temperatures, melting the snow and allowing to detect snow
precipitations. The instrument external circular dome acts as a windshield for
the sensor, preventing false indications. The instrument is equipped with three
different outputs: a "Rain ON/OFF" output, which detects whether it is raining/
snowing (ON) or not (OFF), also used to control a relay coil or similar devices; a
0…1V voltage analogue output (calibrated) and a 1,5…6KHz frequency output
(not calibrated), which provide an accurate indication of current precipitation
intensity. The ON/OFF output comes with a delay circuit that indicates the
"rain over" condition with a 2 minute delay, so that the "rain over" condition is
distinguished from the "light rain" one. The heater can be disabled when power
consumption is critical. To do it, set the Heater OFF input on 0V.
If requested when ordering, a bird spike, consisting of a 6-spike ring (spike
height: 60mm, diameter: 3 mm), can be mounted.
Typical Applications
The rain detector can be used either as a separate device, or connected to a data
logger system (for example: in a weather station). In figure 1, the HD2013.2 ON/
OFF output is connected to a relay coil that powers an engine: should it rain, the
ON/OFF output will energize the relay coil, which will close the normally open
contact (in this case the rain detector is employed as part of a control system,
such as, for example, for closing windows). Warning: when the HD2013.2 is
connected to a relay coil, use always a protection diode, as shown in figure 1.
Installation and Maintenance
Place the detector far from buildings, trees, etc…, taking care that no object
is over the detector, as it might prevent rain detection. Use the supplied
accessories to mount the instrument; the bracket can be fixed to a post having
a diameter from 30 to 50mm; the post can be either horizontal or vertical
thanks to the bracket double drilling. A standard 5-m cable is supplied for the
electrical connection with an IP68 connector to be inserted at the bottom of
the instrument: the colours of the leads and the relating functions are to be
found in the technical specifications. To ensure good immunity from noises, it is
recommended to connect the cable braid to the earth and to keep the heater and
the electronics earth leads separate. Clean the sensor regularly with a cotton
flock soaked in distilled water; in case of ingrained dirt, mild cleansers can be
used in moderation.
The sensor is fragile, as it is placed on an alumina rest, thus handle it with
care!
More products SENSECA
|
PH AND MV-METER SIMULATOR CALIBRATING KIT DELTA OHM HD9609
• pH/mV simulator kit composed of instrument HD9609, |
|
LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2
• Bench-top pHmeter-Conductivity meter-Thermometer |
|
DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT PMV PPD DELTA OHM HD32.3 HD32.3A
• Analysis of hot environments using WBGT index |
|
THREE-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION DELTA OHM HD2070
• portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously |
|
LUXMETER PHOTO- RADIOMETER MEASURING SOLAR ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2102.1 HD2102.2
• Device for measuring illuminance, luminance, PAR, irradiance. |
|
PHOTOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR ILLUMINANCE DELTA OHM LP PHOT02
• Outdoor photometric probe for measuring ILLUMINANCE (0...150 Klux), |
|
SILICON PHOTODIODE PYRANOMETER WITH GLOBAL SOLAR RADIATION MEASUREMENT FOR PHOTOVOLTAIC PANELS DELTA OHM LP SILICON-PYRA04
• LP Silicon-PYRA 04. pyranometer |
|
SECONDARY CLASS PYRANOMETER FOR DIRECT SOLAR IRRADIANCE ON FLAT SURFACE AND GLOBAL RADIATION DELTA OHM LP PYRA10
• measures the irradiance on a flat surface (Watt/m2) |
|
LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD2206.2
• Bench-top conductivity meter-Thermometer with back-lighted display, |
|
ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2
• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module. |