Meteo Pirgeometer for Infrared Radiation Measurement Delta Ohm LP PIRG01

Code: Delta Ohm LP PIRG01


 

Datasheet PDF, 0.88 Mb

Description

The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).

Its use is mainly in the meteorological field. Measures are referred to radiations

with wavelength greater than 4.5 µm .

The far infrared radiation derives from the measure of the thermopile output

signal and from the knowledge of the instrument temperature. The temperature

measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.

The pyrgeometer can be used also for the study of energy balance. In this case,

besides another pyrgeometer which measures infrared radiation upwards, it is

necessary an albedometer (LP PYRA 05 or LP PYRA 06) to measure short wavelengths

radiation (<3µm) .

 

More products SENSECA

MULTIPARAMETRIC PH-METER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

METEO DATALOGGER WITH DATA ACQUISITION AND RECORDING DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

PH AND MV-METER SIMULATOR CALIBRATING KIT DELTA OHM HD9609

• pH/mV simulator kit composed of instrument HD9609,
• adapter cables CP 9509/T,
• CP9509/BNC and
• carrying case.

 

RAIN DETECTOR AND ATHMOSPHERICAL PRECIPITATION DELTA OHM HD2013.2

• rain detector based on the capacity principle
• The instrument is equipped with three different outputs: a "Rain ON/OFF" output
• detects whether it is raining/ snowing (ON) or not (OFF), also used to control a relay coil or similar devices
• can be used either as a separate device, or connected to a data logger system

 

ALBEDOMETER PYRANOMETER FOR GLOBAL INCIDENT SOLAR RADIATION DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

PLUVIOMETER RAIN GAUGE FOR ATMOSFERIC PRECIPITATION DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

THREE-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION DELTA OHM HD2070

• portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• simplicity of use with maximum flexibility
• possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement
• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT PMV PPD DELTA OHM HD32.3 HD32.3A

• Analysis of hot environments using WBGT index
• Analysis of the moderate warm environments using PMV index and PPD index
• Logging
• Start and stop can be set automatically with the auto-start function
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.