Power Current Clamp Meter Metrel MD 9240

Code: Metrel MD 9240


 

Datasheet PDF, 0.28 Mb
 

Description

The MD 9240 is a high-quality and extremely easy to handle power clamp meter. The current clamp enables TRMS AC current measurement up to 1000 A, single-phase power analysis, DC, AC voltage measurement, temperature measurement and more.

 

TEST FUNCTIONS

  • DC and TRMS AC voltage up to 600 V
  • TRMS AC current measurement up to 1000 A
  • Resistance measurement
  • Continuity test
  • Frequency measurement
  • Contact temperature measurement
  • Power factor
  • Power (W, VA, Var)

 

TECHNICAL DATA

Dimensions (w x h x l): 78 x 40 x 224 mm

Mass (without accessories): 224 g

 

Standard accessories

MD 9240 Standard set

  • Current clamp MD 9240
  • Test lead with probe, 2 pcs
  • Temperature probe, type K
  • 1.5 V battery, type AAA, 2 pcs
  • Pouch
  • Instruction manual
  • Warranty
 

More products METREL

THREE-PHASE ACTIVE ADAPTER FOR TESTING POLARITY, DIFFERENTIAL LEAKAGE AND RCD'S METREL A1322

• All tests on 3-phase electrical equipment can be carried out, including live leakage test, power, polarity, RCD and Active polarity.
• Simple connection to the PAT/MACHINE tester with automatic detection.
• Simple test procedures, identical to single phase equipment.
• Test sequence for 3-phase tests are automatically set, based on entered test codes and input voltages.

 

DEMONSTRATION BOARD FOR SHOWING ELECTRICAL SWITCHBOARD IN SINGLE AND THREE-PHASE SYSTEMS METREL MI 3099 DEMO

• Switchboard and on Circuit side
• supporting one and three phase system
• RCD can be simulated
• TN-C(S) or TT type of earthing system on electrical installation

 

METREL A1143 EURO Z 290 A LOW LINE AND FAULT LOOP IMPEDANCE TESTER

• High precision line impedance;
• High precision fault loop impedance;
• Contact voltage.
• Range widening: adapts the instruments to read from 0.1 m? up to 19.99 ?.
• Multi-system testing: works on both single phase and 3-phase systems (110 V to 440 V).

 

TRAINING PLATFORM FOR STUDY INDUSTRIAL AND RESIDENTIAL INSTALLATIONS METREL MA 2067 DEMO

• Complete representation of a real low voltage installation in industrial and residential areas
• sockets,
• electrical loads,
• lightning,
• earthing systems for TT, TN and IT types of installations.
• 65 different measurements according to IEC/EN61557 are supported.
• Fault situation simulation switches can generate 19 errors or combination of these
• Detailed instruction manual with profound explanation of all typical measurements.

 

METREL MI2093 LINE TRACER FUSE FINDING INSTALLATION TESTER FOR UNDER-WALL CABLES

• Field proven instrument for under-wall low voltage installation tracing
• fuse finding
• short-circuit spot determination and metal installation tracing
• Can be used on energized or voltage-free systems.
• Tips and detailed descriptions of connection schemes for various combinations from everyday practice.

 

METREL MI3121 INSOLATION RESISTANCE MEGOHMMETER 2500V AND CONTINUITY METREL MI 3121H SMARTEC 2.5KV

• Insulation resistance up to 100 GO with DC voltage up to 2.5 kV;
• PI, DAR calculation;
• Continuity of PE conductors with 200 mA test current and polarity change;
• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping;
• TRMS voltage and frequency.

 

METREL MI2142 ALPHA-PAT ELECTRICAL SAFETY ANALYZER CF. IEC EN VDE STANDARD

• Functional and visual inspection;
• Earth bond resistance;
• Insulation resistance;
• Substitute leakage current;
• Differential leakage current test;
• Touch leakage test;
• IEC cord polarity test;

 

METREL MI3103 GIGAOHM INSULATING RESISTANCE MEGOHMMETER 1KV AND CONTINUITY TESTER

• Insulation Resistance: Three different test voltages (250, 500 and 1000 V)
• Continuity: 200 mA measurement with automatic polarity change.
• RMS Voltage and Frequency
• Warnings are given if hazardous voltages are detected.
• Auto power-off.

 

METREL MI3102 INSULATING RESISTANCE MEGOHMMETER 1000V, CONDUCTOR CONTINUITY, EARTHINGTEST EUROTEST XE

• DC insulation resistance,
• PE conductor continuity test,
• Line and Loop resistances with Fuse evaluation table built-in,
• RCD test with Trip lock function, phase sequence in 3-phase systems,
• on-line voltage monitor,
• 3-wire Earth resistance test with built-in battery operated generator,
• Leakage Current test,
• test of Luminance with optional LUX meter probe.

 

PRECISION CURRENT CLAMP METER TRUE RMS METREL MD 9250

• meets overvoltage category CAT IV 1000 V
• TRMS AC, DC voltage measurement;
• TRMS AC, DC current measurement;
• Capacitance measurement;
• Resistance measurement;
• Diode test;
• Frequency measurement;
• Electric field detection;
• Continuity test (acoustic signaling);
• Temperature measurement.