Megger MTO210 Transformer Winding Ohmmeter

Code: Megger MTO210


 

Datasheet PDF, 0.54 Mb
   

Description

• Direct 2-channel digital reading (1 µO to 2000 O)
• DC test current up to 10 A maximum
• 0.25% measurement accuracy
• Integrated demagnetization feature
• Tests operation of on-load tap-changers
• Very fast auto safety discharge circuit 

 

The MTO210 Transformer Ohmmeter is a line-operated, field-portable instrument designed specifically to measure the dc resistance of all types of magnetic windings safely and accurately. It can test transformers and rotating machine windings and perform low-current resistance measurements on connections, contacts and control circuits. 

The Transformer Ohmmeter is extremely useful when testing the windings and contact resistance of tap-changers with "make-before-break" contacts and voltage regulators. This action will check for pitted or misaligned contacts as the instrument will give an indication if either condition occurs.

 

Standard accessories

Transformer Ohmmeter

120/240 volt, 50/60 Hz input MTO210

 

Included Accessories

V1 Potential Lead Set, 60 ft (18 m) 2000-700

V2 Potential Lead Set, 60 ft (18 m) 2000-701

Current Lead Set, 60 ft (18 m) 2000-702

Jumper Lead, 30 ft (9 m) 2000-703

Ground Lead, 15 ft (4.5 m) 4702-7

RS232 Cable for connecting to a PC and Printer CA-RS232

Remote Hand Switch 30915-220

AC Power Cord (IEC60320-C13 to US standard) 17032

AC Power Cord (IEC60320-C13 to Schuko CEE 7/7) 17032-13

Quick Start Guide 37178

Canvas Carrying Bag (for leadset) 30915-211

CAT5e Patch Cable 36798

Instruction Manual ATVMMTO210

PowerDB LITE

 

Recommended options

Optional Accessories

V1 Potential Lead Set, 100 ft (30 m) 2001-403

V2 Potential Lead Set, 100 ft (30 m) 2001-404

Jumper Lead, 50 ft (15 m) 2001-405

Current Lead Set, 100 ft (30 m) 2001-406

Kelvin Lead Set, 60 ft (18 m) 2001-407

Kelvin Lead Set, 100 ft (30 m) 2001-408

Test Lead Set, 60 ft (18 m) including V1, V2,

Current and 30 ft (9 m) Jumper Lead 1001-425

Test Lead Set, 100 ft (30 m) including V1, V2,

Current and 50 ft Jumper Lead 1001-451

Beacon Strobe Light 37181

Printer (includes battery/line powered serial thermal printer)

120 V, 60 Hz 1001-390

230 V, 50 Hz 1001-401

Foam-lined Transit Case 37009

USB to Ethernet Adapter 90001-541

PowerDB (full version) Software,

1st machine license, soft key DB1001

PowerDB (full version) Software,

1st machine license, USB dongle DB1001S

 

 

More products MEGGER

MEGGER MIT1525/2 15KV ADVANCED INSULATION RESISTANCE MEGOHMMETER

• Diagnostic testing with full test suite
• PI Predictorâ„¢ cuts test time in half
• Accurate testing with RE>Actâ„¢
• Built-in storage and easy data export
• Designed for safe testing in the field

 

MEGGER DELTA4110 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA4000

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 


PHOTOVOLTAIC KIT MEGGER - PVK320

• PVM210 irradiance meter
• AVO410 CATIV TRMS multimeter
• C4 solar connectors to 4 mm standard plug test leads
• MC3 to MC4 adapter test leads
• PV kit storage pouch

 

ELECTRICIAN'S MULTIMETER MEGGER - AVO410

• 6000 count backlit digital display
• True RMS reading on a.c. mode
• 1000 V d.c. / 750 V a.c. ranges
• 10 A a.c. / d.c. ranges

 

MEGGER IDAX-300 IDAX-350 INSULATION DIAGNOSTIC ANALYZER, TAN DELTA, POWER FACTOR

• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity
• Individual temperature correction (ITC) of tan delta/power factor and oil conductivity
• 40% faster measurements with the new IDAX 5.0 SW
• Reliable measurements in high-interference environments
• Multi-function test set for transformer measurements

 

MEGGER DLRO10HD 10A MICROHMMETER LOW RESISTANCE MEASUREMENTS

• High or low output power selection for condition diagnosis
• Rechargeable battery or line power supply, continuous operation, even with dead battery
• 10 A for 60 seconds, less time waiting to cool, great for charging inductance
• High input protection to 600 V, inadvertent connection to line or UPS voltage will not blow a fuse
• Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only)
• Rotary switch selects one of five test modes, including auto start on connection, giving ease of use

 

MEGGER TDR500/3 TIME DOMAIN REFLECTOMETER & CABLE FAULT LOCATOR 1002-227

• minimum resolution of 0.1 m and a 5 km maximum range
• Simple operation.
• AUTO selection of gain and pulse width.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

BOND TESTER MEGGER - BT51

• High test current
• Four terminal measurement
• Two measuring ranges (2000 mO. and 20,00 mO.)and maximum resolution of 0,01 mO.
• Protected against inadvertent connection to the mains supply

 

BATTERY GROUND FAULT LOCATOR MEGGER - BGL

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes