Megger BITE3 Battery Impedance Tester

Code: Megger BITE3 Biddle


 

Datasheet PDF, 0.45 Mb
           

Description

• Determines health of lead-acid cells up to 2000 Ah
• On-line testing with Pass/Warning/Fail calculations
• Measures impedance, interconnection resistance and cell voltage
• Windows CE operating system with 32 MB of memory
• Measures float and ripple currents
• Includes PowerDB LITE Management Software

 

The Megger BITE3 Battery Impedance Test Equipment determines the health of lead-acid cells up to 2000 Ah by taking measurements of the most important battery parameters. The BITE3 measures cell impedance, an internal ohmic test, cell voltage, intercell connection resistance and ripple current. And, for the first time in a battery instrument, the BITE3 measures float current and the harmonic content of the ripple current. There is even a built-in spectrum analyzer to show the harmonic content of the ripple current. It has firmware that can be upgraded through the Internet and supports multiple languages.

The BITE3 is one of the easiest instruments to use. Its measurements, along with temperature, specific gravity and other battery data, can provide the best basis for evaluating the overall health of batteries from terminal plate to terminal plate and to a lesser extent, the charger (from ripple current and its harmonic content.) Megger recommends that the BITE3 be made part of a comprehensive battery maintenance program with readings taken and recorded semi-annually for flooded, lead-acid cells and quarterly for VRLA.

The BITE3 is quick, reliable and easy to use. With a rapid test time, one person can easily, quickly and precisely measure cell and string parameters without taking the system off line.

 

Standard accessories

BITE3, 110/230 V ac, 50/60 Hz, CE-marked BITE3

Included Accessories

  • PowerDB software 1001-381
  • Canvas carrying case 35788
  • RS-232 null modem cable 33533-1
  • Line charger 6280-333
  • Battery 6121-492
  • Dual-point lead set BI-10002
  • Tip kit BI-10017
  • Operating manual AVTMBITE3
 

Recommended options

Optional Accessories

  • Lead set, 6 ft (1.8 m) probe to probe 36616
  • Printer, battery-operated, 110 V ac 35755-3
  • Printer, battery-operated, 220 V ac 35755-4
  • Printer paper, 1 roll 26999
  • AMP/Burndy lead set BI-10004
  • Kelvin clip lead set BI-10005
  • Quick Disconnect lead set BI-10006
  • Cigarette lighter charger 6280-332
  • Current transformer kit 35873
  • USB-serial adapter 35871
  • Probe extensions, lighted 35865
  • Hard-sided carrying case 35890
  • Standard transit case 35915
  • Field test shunt, 0.01 O, current rating 10 A 249003
  • Field test shunt, 0.001 O, current rating 100 A 249004
  • Field test shunt, 0.0001 O, current rating 500 A 249005
 

More products MEGGER

AC VOLTAGE DETECTORS MEGGER - VF1 AND VF2

• Socket outlets
• Fuses
• Switches
• Wires and cables
• Circuit breakers
• Luminares

 

MEGGER MFT-X1 MULTIFUNCTION LOW VOLTAGE ELECTRICAL INSTALLATION TESTER

• Patented Confidence Meter™ for True Loop™ testing
• Easy certificate generation and reporting
• User upgradeable operating system
• Intuitive interface for ease of use
• Comprehensive EV Testing Capability

 

MEGGER S1-568/2 EXPERT 5000V 5KV INSULATION RESISTANCE MEGOHMMETER

• Reliable results in noisy substations
• Accurate testing with RE>Act™
• Remote control for safer, easier testing
• PI Predictor™ cuts test time in half
• Full diagnostic suite with PDC capability

 

MEGGER TM1700 CIRCUIT BREAKER ANALYZER TM1710 TM1720 TM1740 TM1750 TM1760

• Provides reliable and accurate test results in noisy high voltage substations
• Four standard models. Full stand-alone functionality or data acquisition models without user interface.
• Fast and safer with DualGround™ testing, both sides of breaker grounded
• On-screen assistance with connection diagrams and test template Wizard
• All models can be controlled via computer

 

MEGGER GOOSER IEC 61850 RELAY TESTER

• Reliable testing of IEC61850 relays using a conventional relay test set
• Separate Ethernet ports for the substation LAN and the controlling PC forming a Safe Substation Bus Access Point
• Seamless interaction between SCL GOOSE and GOOSE "sniffing"
• GOOSE merge - SCL GOOSE vs captured GOOSE for network troubleshooting and SCD file validation at FAT
• Stand alone functionality - Download a configuration and run

 

MEGGER - MS2A CIRCUIT BREAKER AND OVERCURRENT RELAY TEST SET

• Light Weight, Portable Primary Injection Test Instrument
• Overcurrent Relay Testing
• Ground Fault Performance Testing for NEC 230.95
• Circuit Breaker Testing

 

MEGGER SVERKER900 THREE PHASE RELAY TESTER

• The toolbox for substation 3-phase testing
• Three currents and four voltages
• Stand-alone functionality
• Rugged and reliable for field use
• Generation of 900 V and 105 A in single phase mode
• Secondary and primary testing

 

MEGGER MTO300 MTO330 TRANSFORMER SIX-WINDING OHMMETER MTO3XX

• Automated 8-terminal/6-winding measurement capability
• Simultaneous winding magnetization
• Tests operation of on-load tap-changers
• Built-in auto-demagnetization feature
• Automatic discharge
• Power DB software (MTO330)

 

MEGGER MIT300 MIT310 MIT320 MIT330 INSULATION AND CONTINUITY TESTER

• Extremely easy to use
• Tough rubber armoured case
• Self contained protective cover
• Live circuit warning
• Weatherproof to IP54

 

BATTERY VOLTAGE MONITOR MEGGER - BVM, BVM300 AND BVM600

• Automates battery voltage measurement during capacity tests
• ½Daisy-chain½ design allows expandability up to 120 units
• High accuracy and stability for precise data collection