Description
• Determines health of lead-acid cells up to 2000 Ah
• On-line testing with Pass/Warning/Fail calculations
• Measures impedance, interconnection resistance and cell voltage
• Windows CE operating system with 32 MB of memory
• Measures float and ripple currents
• Includes PowerDB LITE Management Software
The Megger BITE3 Battery Impedance Test Equipment determines the health of lead-acid cells up to 2000 Ah by taking measurements of the most important battery parameters. The BITE3 measures cell impedance, an internal ohmic test, cell voltage, intercell connection resistance and ripple current. And, for the first time in a battery instrument, the BITE3 measures float current and the harmonic content of the ripple current. There is even a built-in spectrum analyzer to show the harmonic content of the ripple current. It has firmware that can be upgraded through the Internet and supports multiple languages.
The BITE3 is one of the easiest instruments to use. Its measurements, along with temperature, specific gravity and other battery data, can provide the best basis for evaluating the overall health of batteries from terminal plate to terminal plate and to a lesser extent, the charger (from ripple current and its harmonic content.) Megger recommends that the BITE3 be made part of a comprehensive battery maintenance program with readings taken and recorded semi-annually for flooded, lead-acid cells and quarterly for VRLA.
The BITE3 is quick, reliable and easy to use. With a rapid test time, one person can easily, quickly and precisely measure cell and string parameters without taking the system off line.
Standard accessories
BITE3, 110/230 V ac, 50/60 Hz, CE-marked BITE3
Included Accessories
Recommended options
Optional Accessories
More products MEGGER
|
MEGGER TM1800 CIRCUIT BREAKER ANALYZER CG-19290 CG-19292 CG-19294 CG-19296
• Modular based design - user configurable TM1800 from nine different modules |
|
MEGGER BITE3 BATTERY IMPEDANCE TESTER
• Determines health of lead-acid cells up to 2000 Ah |
|
MEGGER DELTA4110 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA4000
• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set |
|
MEGGER S1-1068/2 EXPERT 10KV INSULATION RESISTANCE MEGOHMMETER
• Reliable results in noisy substations
|
|
MEGGER TTR100 TRANSFORMER TURNS RATIO METER, PHASE DISPLACEMENT, VECTOR GROUP, POLARITY
• Tests turns ratio, phase displacement, excitation current, vector group, winding resistance and polarity |
|
COMBINED LOOP AND RCD TESTERS MEGGER - LRCD210 AND LRCD220
• Non-trip loop tester
|
|
MEGGER TM1700 CIRCUIT BREAKER ANALYZER TM1710 TM1720 TM1740 TM1750 TM1760
• Provides reliable and accurate test results in noisy high voltage substations |
|
MEGGER MOM2 220A MICROHMMETER BD-59090 BD-59092 BD-59093
• Up to 220 A |
|
MEGGER FRAX FRAX-99 FRAX-101 FRAX-150 FREQUENCY RESPONSE ANALYZER
• Frequency range 0.1 Hz - 25 MHz, user selectable |
|
MEGGER MIT400/2 MIT410/2 MIT420/2 MIT430/2 CAT IV INSULATION TESTER WITH 1000V
• nsulation testing up to 1000 V and 200 GΩ range
|