Megger TORKEL 820 BS-49092 Telecom Battery Load Discharge Tester Programma

Code: Megger TORKEL 820 BS-49092 TLX830 TLX850 Programma


 

Datasheet PDF, 0.49 Mb
           

Description

• Combines efficiency with portability

• Batteries can be tested "in service"

• Discharge 24 and 48 V batteries at a current of 270 A 
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current. 
• Discharging proceeds at constant current, constant power or constant resistance, or in accordance with a pre-selected load profile.

Batteries can be tested "in service"

 

??Unit adjusts to include load currents in the test parameters

??User adjustable alarm and shutdown points to avoid excessive discharge

??View test parameters/results "real time" as testing progresses using TORKEL WIN

software

??Easily save results to a PC for analysis, report generation and storage

 

 

 

During a power outage, crucial telecommunication and radio equipment must be kept operating by batteries. Unfortunately, however, the capacity of such batteries can drop significantly for a number of reasons before their calculated life expectancy is reached. Battery capacity should thus be checked to prevent expensive downtime in the event of a power failure.

 

Standard accessories

TORKEL 820

Complete with:

  • Cable set GA-00554
  • Transport case GD-00054 BS-49092
 

Recommended options

Optional

TORKEL Win PC software BS-8208X

Extra loads

TXL830 BS-59093

TXL850 BS-59095

 

Cable sets

Cable set for TXL830 and TXL850 2 x 3 m, 70 mm2, with cable lug. Max 100 V 270 A. Weight: 5.0 kg (11 lbs) GA-00554

Sensing lead set

Cable set for measuring voltage at battery terminals. 2 x 5 m (16.4 ft) GA-00210

Clamp-on ammeters

DC clamp-on ammeter, 200 A To measure current in circuit outside TORKEL XA-12992

DC clamp-on ammeter, 1000 A To measure current in circuit outside TORKEL XA-12990

 

BVM

Including:

Dolphin clips, Power & signal connector, Power supply, Connection cables and Carrying case

BVM150 With TORKEL Win software System of 16 BVM units CJ-59092

BVM300 With TORKEL Win software System of 31 BVM units CJ-59093

BVM600 With TORKEL Win software System of 61 BVM units CJ-59096

BVM150 With PowerDB software System of 16 BVM units CJ-59192

BVM300 With PowerDB software System of 31 BVM units CJ-59193

BVM600 With PowerDB software System of 61 BVM units CJ-59196

 

More products MEGGER

CURRENT SUPPLY UNIT MEGGER ½ CSU600A AND CSU600AT

• Compact and rugged
• Quick and easy to us
• Broad application range
• Excellent weight/performance ratio

 


MEGGER SMRT33 THREE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output - (45 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MULTI-AMP CIRCUIT BREAKER TESTER RETROFIT MEGGER DDA16, DDA30 AND DDA60

• Drop-in retrofit capability to the Multi-Amp Model CB-9116, Model DB-8130 and Model CB-8160 circuit breaker test sets
• Digital Signal Processing (DSP) technology
• Variable pulse time and firing-angle output-current control
• Complies with NEMA AB-4 Test Guidelines

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

MEGGER DLRO10X RESISTANCE OHMMETER DLRO 10 DLRO 10X 6111-428 6111-429

• up to 10A current
• Accurate results in under three seconds
• Auto current reversal cancels standing emfs
• Fuse protected to 600 V
• NiMH battery reduces weight
• 250 mW power limit (with optional override) to avoid heating the test sample

 

MICROPROCESSOR-BASED CIRCUIT BREAKER TEST SETS MEGGER PS-9116

• Portable, three piece chassis
• Tests wide range of air-frame breakers
• Test result printout capability

 

KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER ½ KF875 AND KF-LAB MKII

• Coulometric Karl Fischer titrimetry
• KF875 optimized for insulating oil with an SG of 0.875, completely portable
• KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
• KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875

 

TRMS CLAMP METER MEGGER - DCM1500

• DC and AC current up to 1500 A
• True RMS measurement for greater accuracy
• Large jaw size safely assists with uninsulated conductor measurements
• 750 Vac and 1000 Vdc

 

MEGGER DLRO600 DUCTER MICRO-OHMMETER 600A

• Small and weighs less than 33 lbs (15 kg)
• Test currents from 10 A to 600 A dc
• 0.1 µohms best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer