KEITHLEY DMM6500 6.5digit Multimeter High precision

Code: DMM6500 DMM-6500


 

Datasheet PDF, 2.98 Mb

Description

Keithley DMM6500 6.5 Digit Multimeter with Graphical Touchscreen

0.0025% DCV accuracy (1 year)
1 Msample/s digitizing, 16-bits
10-channel scan card option
100 nV
10 pA
1 µOhm

 

More products KEITHLEY

DATA ACQUISITION CARD PCI 16-CHANNELS 400KSA/S KEITLHEY KPCI-3103

• 12-bit resolution
• Throughput of up to 400kS/s
• Digital I/O scanning speeds of up to 3MHz
• 16 single-ended or 8 differential analog inputs
• 23 digital I/O lines

 

DIGITAL PRECISION MULTIMETER 6.5 DIGIT KEITHLEY DMM 2000

• 6.5 digit resolution
• 0.002% 90-day basic accuracy
• 2000 readings/second at 4-1/2 digits

 

KEITHLEY 4200A-SCS I-V SEMICONDUCTOR CURVE TRACER PARAMETER ANALYZER

• Move C-V measurement to any device terminal without re-cabling
• User-configurable for low current capability
• Personalize the names of output channels
• View real-time test status

 

KEITHLEY DMM7510 PRECISION MULTIMETER 7.5-DIGIT LABORATORY BENCH

• 0.0014% DCV accuracy (one year)
• 1,000,000 readings/s digitizer
• Touchscreen display
• DC voltage sensitivity: 10 nV
• Current sensitivity: 1 pA
• Resistance sensitivity: 0.1 µΩ

 

KEITHLEY 2400 2450 2460 2461 2470 SMU SOURCE-METER SMU PRECISION MULTIMETER+SOURCE

• 6½-digit resolution precision source and measure
• 1 MSamples/s digitized measurement speed
• Current: 10 nA to 7 A DC, 10 A Pulse
• Voltage: 200 mV to 200 V
• Power: Up to 100 W DC to 1000 W Pulse

 

PULSE PATTERN GENERATOR 2 X 165 MHZ KEITHLEY 3402-F / 3402-R

• 1 mHz - 165 MHz frequency output range
• 2 channels
• 3 ns - 1000 s pulse width range
• 10 V amplitude into 50 O, 20 V into 1 k O

 

KEITHLEY 2002 8.5-DIGIT PRECISION MULTIMETER

• 0.0006% DCV accuracy (one year)
• 1nV, 100nΩ, and 10pA sensitivity
• DC in-circuit current and 15MHz frequency measurement

 

PRECISION SOURCE-METER KEITHLEY 2400

• Five instruments in one (IV Source, IVR Measure)
• Six models: 20 - 100W DC, 1000W pulsed, 1100V to 1uV, 10A to 10pA
• Source and sink (4-quadrant) operation
• 0.012% basic measure accuracy with 5½-digit resolution

 

PRECISION AC AND DC CURRENT SOURCE KEITHLEY 6221

• Source and sink (programmable load) 100fA to 100mA
• 10^14 O output impedance ensures stable current sourcing into variable loads
• Source AC currents from 2pA to 100mA for AC characterization of components and materials

 

PCI BOARD DIGITAL I/O 32-CHANNELS OPTICALLY ISOLATED KEITHLEY KPCI-PIO32IOA

• 32 optically isolated solid-state relays and digital inputs
• Direct, non-polarized switching and sensing: DC up to 60VDC, AC up to 30Vrms
• High load current capability up to 350mA