KEITHLEY 6514 6517B 6430 Electrometer low current high resistance

Code: KEITHLEY 6514 6517B 6430


 

Datasheet PDF, 1.72 Mb
Datasheet PDF, 0.91 Mb
Datasheet PDF, 0.9 Mb

Description

Keithley Electrometer Series 6500 & 6430

Choose from three sensitive electrometers for precision high resistance and low current measurements. The 5½-digit Model 6514 and Model 6517B Electrometers offer 1fA sensitivity, >200TΩ input impedance on voltage measurements, and charge measurements down to 10fC. The 6½-digit Model 6430 Sub-Femtoamp Remote SourceMeter SMU Instrument can measure current with 1aA sensitivity. Its low noise and drift performance make it ideal for research on single electron devices, highly resistive nanowires and nanotubes, polymers, and electrochemical applications.

ModelCurrent RangeVoltageResistanceChargeSourceList Price

6514100aA - 20mA10µV - 200V
10mΩ - 200GΩ

10fC - 20μC

11.400,00 €

6517B
10aA - 20mA

10µV - 200V
100Ω - 10PΩ

10fC - 2μC
0 - ±1000V

14.500,00 €


643010aA - 100mA1µV - 200V
1µΩ - >20TΩ

-
0 - ±200V
0 - ±100mA

32.800,00 €

 

More products KEITHLEY

PULSE PATTERN GENERATOR 165 MHZ KEITHLEY 3401-F / 3401-R

• 1 mHz - 165 MHz frequency output range
• 1 channel
• 3 ns - 1000 s pulse width range
• 10 V amplitude into 50 O, 20 V into 1 k O

 

6-SLOT MODULAR SYSTEM SWITCH, DMM KEITHLEY 3706

• Multiplexer, matrix, and I/O cards
• Relay closures automatically counted and stored in each card's onboard memory

 

KEITHLEY DMM7510 PRECISION MULTIMETER 7.5-DIGIT LABORATORY BENCH

• 0.0014% DCV accuracy (one year)
• 1,000,000 readings/s digitizer
• Touchscreen display
• DC voltage sensitivity: 10 nV
• Current sensitivity: 1 pA
• Resistance sensitivity: 0.1 µΩ

 

KEITHLEY 4200A-SCS I-V SEMICONDUCTOR CURVE TRACER PARAMETER ANALYZER

• Move C-V measurement to any device terminal without re-cabling
• User-configurable for low current capability
• Personalize the names of output channels
• View real-time test status

 

DIGITAL MULTIMETER 6.5 DIGIT AND THD AUDIO ANALYZER KEITHLEY 2015

• 6.5 digit DMM
• THD, THD+Noise and SINAD measurements
• 20Hz-20kHz sine wave generator
• 4Vrms single-ended or 8Vrms differential output
• Identifies peak spectral components(2015-P model)

 

PRECISION SOURCE-METER KEITHLEY 2400

• Five instruments in one (IV Source, IVR Measure)
• Six models: 20 - 100W DC, 1000W pulsed, 1100V to 1uV, 10A to 10pA
• Source and sink (4-quadrant) operation
• 0.012% basic measure accuracy with 5½-digit resolution

 

KEITHLEY 2002 8.5-DIGIT PRECISION MULTIMETER

• 0.0006% DCV accuracy (one year)
• 1nV, 100nΩ, and 10pA sensitivity
• DC in-circuit current and 15MHz frequency measurement

 

USB MODULAR DATA ACQUISITION UNIT USB 8-CHANNELS 50KSA/S KEITLHEY KUSB-3100

• USB 2.0 and USB 1.1, true plug-and-play compatibility
• 8 SE analog input channels
• 12-bit resolution
• Input/output speeds up to 50kS/s
• High and low programmable gains
• Up to 16 digital I/O lines

 

KEITHLEY 2400 2450 2460 2461 2470 SMU SOURCE-METER SMU PRECISION MULTIMETER+SOURCE

• 6½-digit resolution precision source and measure
• 1 MSamples/s digitized measurement speed
• Current: 10 nA to 7 A DC, 10 A Pulse
• Voltage: 200 mV to 200 V
• Power: Up to 100 W DC to 1000 W Pulse

 

PCI BOARD 8-ANALOG OUTPUT KEITHLEY KPCI-3132

• 20mA output current without power supply
• 2 analog outputs