KEITHLEY 2182A Nanovoltmeter

Code: 2182A 2182A/J


 

Datasheet PDF, 1.24 Mb

Description

Keithley Nanovoltmeter Model 2182A

The two-channel Model 2182A Nanovoltmeter is optimized for making stable, low noise voltage measurements and for characterizing low resistance materials and devices reliably and repeatably. It provides higher measurement speed and significantly better noise performance than alternative low voltage measurement solutions. It offers a simplified delta mode for making resistance measurements in combination with a reversing current source, such as the Model 6220 or 6221.

Features
Benefits
1nV sensitivityProvides accurate, ultra-low voltage measurements.
Typically just 15nVp-p noise at 1s response time, 40–50nV p-p noise at 60msEnsures low noise levels over a wide range of useful response times.
Dual channels  Supports measuring voltage, temperature, or the ratio of an unknown resistance to a reference resistor.
Measurement cycle is synchronized to the power line AC cycle  Minimizes variations due to readings that begin at different phases of the line cycle. The result is exceptionally high immunity to line interference with little or no shielding and filtering required.
Built-in thermocouple linearization and cold junction compensationSimplifies making accurate temperature measurements.
Internal polarity reversal measurement techniqueEliminates thermal error sources.
Optimized for use with Model 6220/6221 current sourcesAllows both instruments to be operated like a single instrument when making differential conductance, pulsed, and resistance measurements.
Delta mode current reversal measurement technique when combined with the 6220 or 6221  Enables resistance measurements down to 10nΩ.
2182A/6221 combination synchronizes signal pulses and measurementsMinimizes the amount of power dissipated into a temperature-sensitive DUT.

2182A1nV - 100V-200°C - 1820°C10nΩ to 200MΩ (requires 6220 or 6221)21,024rdgs7.460,00 €

 

More products KEITHLEY

DIGITAL PRECISION MULTIMETER 7.5 DIGIT KEITHLEY DMM 2001

• 7.5 digit true resolution
• 8k Memory(optional 32k or 128k)
• Exceptional measurement integrity with high speed
• Broad range of built-in measurement functions

 

6-SLOT MODULAR SYSTEM SWITCH, DMM KEITHLEY 3706

• Multiplexer, matrix, and I/O cards
• Relay closures automatically counted and stored in each card's onboard memory

 

KEITHLEY 2400 2450 2460 2461 2470 SMU SOURCE-METER SMU PRECISION MULTIMETER+SOURCE

• 6½-digit resolution precision source and measure
• 1 MSamples/s digitized measurement speed
• Current: 10 nA to 7 A DC, 10 A Pulse
• Voltage: 200 mV to 200 V
• Power: Up to 100 W DC to 1000 W Pulse

 

DATA ACQUISITION CARD PCI 32-CHANNELS 1.25MSA/S KEITLHEY KPCI-3110

• 12-bit resolution
• Maximum sampling rate of 1.25MS/s
• 32 single-ended or 16 differential analog inputs
• 2 analog outputs, waveform quality, up to 500kS/s
• 16 high speed digital I/O lines, up to 3MHz

 

PCI BOARD DIGITAL I/O 16-CHANNELS OPTICALLY ISOLATED KEITHLEY KPCI-PDISO8A

• 16 optically isolated solid-state relays and digital inputs
• Direct, non-polarized switching and sensing: DC up to 60VDC, AC up to 30Vrms
• High load current capability up to 350mA

 

LOW CURRENT PICO AMP METER 5.5 DIGIT KEITHLEY 6485

• 10fA resolution
• 5-1/2 digit resolution
• <200µV burden voltage
• measure currents from 20fA to 20mA

 

KEITHLEY 2650 2651A 2657A HIGH POWER SOURCE-METER

• Highly flexible, four-quadrant voltage and current source/load coupled with precision voltage and current meter
• Offers best-in-class performance with 6½-digit resolution.

 

PICOAMMETER AND VOLTAGE SOURCE 5.5 DIGIT KEITHLEY 6487

• 10fA resolution
• 5-1/2 digit resolution
• <200µV burden voltage
• measure currents from 20fA to 20mA
• source voltage from 200µV to 505V

 

DIGITAL PRECISION MULTIMETER 8.5 DIGIT KEITHLEY DMM 2002

• 8.5 digit true resolution
• 8k Memory(optional 32k or 128k)
• Exceptional measurement integrity with high speed
• Broad range of built-in measurement functions

 

DIGITAL PRECISION MULTIMETER 7.5 DIGIT KEITHLEY DMM 2010

• 7.5 digit resolution
• 100nV rms noise floor
• 7ppm DCV repeatability