KANE9206 QUINTOX Industrial Emissions Gas Analyzer KANE 9206

Code: KANE-945 KANE945 QUINTOX
 
KANE
 
 Product Datasheet (*.PDF - 0.83 Mb)
Catalog KANE International Catalog KANE International (*.PDF - 7.44 Mb)
KANE Gas Analyzers TABEL COMPARATIV KANE Gas Analyzers TABEL COMPARATIV (*.PDF - 0.39 Mb)

» Technical Specs

KANE9206 QUINTOX Fully featured emissions analyser

  • commercial  
  • biomass  
  • oil  
  • sensor option  
  • industrial  
  • made in uk

 

The Quintox can be fitted with any combination of up to five additional electro-chemical sensors plus one complete infra-red module

 

Features

 

Large Graphical Display
Up to 15 lines of text/data can be displayed

 

Wireless link from the handset to the base unit
Offering cable free connection

 

GPS Location
Pinpoint exact test location

 

Wireless & USB connection to PC
Use the KANE LIVE software to monitor readings in “real time”

 

Large Internal memory
Can store up to 64,000 tests

 

Main Purge
Allows sensor zeroing without the need to withdraw the probe from the flue

Refreshes the sensors during long term monitoring

Automatically protects the sensor from being over-ranged

 

Active Flow Control
Compensates for sample pressure fluctuation & filter blocking by adjusting the pump speed to maintain a set sample gas flow rate

 

Built in Printer with additional output to optional portable IR printer
IR printer ideal when working away from the base unit.

 

Differential Pressure measurement with Pitot flow calculation.

 

User selectable languages

 

User selectable standard fuels by country

 

User defined ‘special’ fuels

 

Measures(Standard Kit)
- O2 0-25%
- CO (H2 Compensated)
- 0-4,000ppm
- Pressure 0-150 mbar
- Efficiency 0-100%
- Temperature 0-1100°C with optional probe

 

Electro Chemical Sensors(Optional)

CO (H2 Compensated) 0-10000ppm KCO1/Q

NO (Hi Range) 0-5000ppm KNO1H/Q

NO (Lo Range) 0-100ppm KNO1L/Q

NO2 0-1000ppm KNO2/Q

SO2 (Hi Range) 0-5000ppm KSO2H/Q

SO2 (Lo Range) 0-100ppm KSO2L/Q

H2S 0-1000ppm KH2S/Q

 

Infra-Red Modules(Optional) KHC/Q

CO 0-10%

HC 0-5000ppm

CO2 0-20%

 

Calculates

  • CO2 (calculated) 0-20%

 

Fuels Types

  • Natural Gas
  • Butane
  • Propane
  • LPG
  • 28 sec oil
  • 35 sec oil
  • Wood pellets
  • User fuel
  • Heavy Oil


» Standard included accessories

Box Contents

  • Analyser
  • Handset with cable
  • Charger
  • Manual
  • Calibration report


» Recommended Options, Services and Accessories

Electro Chemical Sensors(Optional)

CO (H2 Compensated) 0-10000ppm KCO1/Q

NO (Hi Range) 0-5000ppm KNO1H/Q

NO (Lo Range) 0-100ppm KNO1L/Q

NO2 0-1000ppm KNO2/Q

SO2 (Hi Range) 0-5000ppm KSO2H/Q

SO2 (Lo Range) 0-100ppm KSO2L/Q

H2S 0-1000ppm KH2S/Q

 

Infra-Red Modules(Optional) KHC/Q

CO 0-10%

HC 0-5000ppm

CO2 0-20%
 

Optional Probes

Depending on your requirement a selection of high quality stainless steel probes with integral thermocouples are available Hi-Temp = 1100°C/2140°F Standard Temp = 600°C/1112°F

 

Hi Temp Probe 1 metre with removeable shaft KMCHLP6

Hi Temp Probe 285mm with removeable shaft KMCHP6

Hi Temp Smoke Probe 1 metre with removeable shaft KMCHSLP6

Hi Temp Smoke Probe 285mm with removeable shaft KMCHSP6

Standard Smoke Probe 285mm with removeable shaft KMCSP6

1 metre removeable shaft KMCLP6

285mm removeable shaft KMCP6

 

 

Optional upgrades

Used in conjunction with the heated probe & heated line, the sample conditioning unit comprises: a peltier fan cooled chiller assembly, a peristaltic pump to automatically remove condensate, the control electronics & power supply module

 

Sample Conditioning Unit KMDM110/230

Heated Probe KMHP1200

Heated Line KMHL3000

 

Hi/Lo CO Protection Solenoid & Pump KHPURQ

Hi/Lo purge protection allows standard ppm sensor to be fitted providing accurate readings at below 20ppm. When approaching over-range the solenoid operates & switches the gas flow to the electro-chemical sensor from flue gas to fresh air. The pump is used to flush out the CO sensor and protect it from over-range CO readings continue to be taken using the CO chanel of the IR bench if fitted

 

Pumped Water Trap WTS9206P

The pumped water trap empties itself on a regular basis & so protects the analyser from condensate overflow, this allows long term unattended monitoring

 

Heater - Toxic Sensors KHSA

Enables toxic sensors to operate effectively at below 0°C ambient temperature. The heater maintains temperature at +5°C

 

 