KANE9206 QUINTOX Fully featured emissions analyser
- commercial
- biomass
- oil
- sensor option
- industrial
- made in uk
The Quintox can be fitted with any combination of up to five additional electro-chemical sensors plus one complete infra-red module
Features
Large Graphical Display
Up to 15 lines of text/data can be displayed
Wireless link from the handset to the base unit
Offering cable free connection
GPS Location
Pinpoint exact test location
Wireless & USB connection to PC
Use the KANE LIVE software to monitor readings in “real time”
Large Internal memory
Can store up to 64,000 tests
Main Purge
Allows sensor zeroing without the need to withdraw the probe from the flue
Refreshes the sensors during long term monitoring
Automatically protects the sensor from being over-ranged
Active Flow Control
Compensates for sample pressure fluctuation & filter blocking by adjusting the pump speed to maintain a set sample gas flow rate
Built in Printer with additional output to optional portable IR printer
IR printer ideal when working away from the base unit.
Differential Pressure measurement with Pitot flow calculation.
User selectable languages
User selectable standard fuels by country
User defined ‘special’ fuels
Measures(Standard Kit)
- O2 0-25%
- CO (H2 Compensated)
- 0-4,000ppm
- Pressure 0-150 mbar
- Efficiency 0-100%
- Temperature 0-1100°C with optional probe
Electro Chemical Sensors(Optional)
CO (H2 Compensated) 0-10000ppm KCO1/Q
NO (Hi Range) 0-5000ppm KNO1H/Q
NO (Lo Range) 0-100ppm KNO1L/Q
NO2 0-1000ppm KNO2/Q
SO2 (Hi Range) 0-5000ppm KSO2H/Q
SO2 (Lo Range) 0-100ppm KSO2L/Q
H2S 0-1000ppm KH2S/Q
Infra-Red Modules(Optional) KHC/Q
CO 0-10%
HC 0-5000ppm
CO2 0-20%
Calculates
Fuels Types
- Natural Gas
- Butane
- Propane
- LPG
- 28 sec oil
- 35 sec oil
- Wood pellets
- User fuel
- Heavy Oil
Electro Chemical Sensors(Optional)
CO (H2 Compensated) 0-10000ppm KCO1/Q
NO (Hi Range) 0-5000ppm KNO1H/Q
NO (Lo Range) 0-100ppm KNO1L/Q
NO2 0-1000ppm KNO2/Q
SO2 (Hi Range) 0-5000ppm KSO2H/Q
SO2 (Lo Range) 0-100ppm KSO2L/Q
H2S 0-1000ppm KH2S/Q
Infra-Red Modules(Optional) KHC/Q
CO 0-10%
HC 0-5000ppm
CO2 0-20%
Optional Probes
Depending on your requirement a selection of high quality stainless steel probes with integral thermocouples are available Hi-Temp = 1100°C/2140°F Standard Temp = 600°C/1112°F
Hi Temp Probe 1 metre with removeable shaft KMCHLP6
Hi Temp Probe 285mm with removeable shaft KMCHP6
Hi Temp Smoke Probe 1 metre with removeable shaft KMCHSLP6
Hi Temp Smoke Probe 285mm with removeable shaft KMCHSP6
Standard Smoke Probe 285mm with removeable shaft KMCSP6
1 metre removeable shaft KMCLP6
285mm removeable shaft KMCP6
Optional upgrades
Used in conjunction with the heated probe & heated line, the sample conditioning unit comprises: a peltier fan cooled chiller assembly, a peristaltic pump to automatically remove condensate, the control electronics & power supply module
Sample Conditioning Unit KMDM110/230
Heated Probe KMHP1200
Heated Line KMHL3000
Hi/Lo CO Protection Solenoid & Pump KHPURQ
Hi/Lo purge protection allows standard ppm sensor to be fitted providing accurate readings at below 20ppm. When approaching over-range the solenoid operates & switches the gas flow to the electro-chemical sensor from flue gas to fresh air. The pump is used to flush out the CO sensor and protect it from over-range CO readings continue to be taken using the CO chanel of the IR bench if fitted
Pumped Water Trap WTS9206P
The pumped water trap empties itself on a regular basis & so protects the analyser from condensate overflow, this allows long term unattended monitoring
Heater - Toxic Sensors KHSA
Enables toxic sensors to operate effectively at below 0°C ambient temperature. The heater maintains temperature at +5°C