Multi-product Calibrator Fluke 5500E
• Handheld digital multimeters
• Bench multimeters (up to 4½ digits)
• Clamp meters
• Electronic thermometers
• Oscilloscope recorders
|
|
|
Universal Calibrator Fluke 9100
• Calibrates over 15 different categories of general-purpose test equipment
• Options for power meter, insulation/continuity tester and oscilloscope calibration
• Semi-automated and fully automated procedure modes
• Fully supported by MET/CAL Plus software
• Intuitive front panel operation for ease of use
|
|
|
Multi-product Universal Calibrator Fluke 5522A
• Handheld and bench meters (analog and digital) up to 6 ½ digits
• Current clamps and clamp meters, Thermocouples and RTDs
• Process calibrators, Data loggers
• Strip and chart recorders, Watt meters
• Power harmonics analyzers, Panel meters
• Graphical multimeters, Power quality analyzers (with option)
|
|
|
Handheld Loop Calibrator Fluke 705
• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.02%
|
|
|
Handheld Loop Calibrator Fluke 707
• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%
|
|
|
Handheld Loop Calibrator Fluke 707Ex
• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%
• For use in explosion endangered areas ATEX certifed ( II 2 G Eex ia IIC T4)
|
|
|
Loop Current Precision Calibrator Fluke 709
• Functions: mA source, mA simulate, mA read, mA read/loop power and volts read
• Best-in-class accuracy at 0.01% reading
• Small rugged design operates on (6) standard AAA batteries
• Intuitive user interface with Quick-Set knob for fast setup, easy use
• Built in selectable 250 Ω resistor for HART communication
|
|
|
Handheld Volt/mA Calibrator Fluke 715
• 0 to 200 mV, 0 to 20 V Voltage measure
• 0 to 100mV, 0 to 10 V Voltage source / simulate
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• very high accuracy of 0.015% and 1 mA resolution
|
|
|
Multifunction Process Calibrator Fluke 725
• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 Ω Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
|
|
|
Intrinsically Safe Calibrator Fluke 725Ex
• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 Ω Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X
|
|
|
Multifunction Process Calibrator Fluke 726
• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 Ω Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
|
|
|
Documenting Process Calibrator Fluke 741B
• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kΩ Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
|
|
|
Documenting Process Calibrator Fluke 743B
• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kΩ Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging
|
|
|
Documenting Process Calibrator Fluke 744
• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kΩ Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging
• Integrated HART communication
|
|
|
Documenting Process Calibrator Fluke 753
• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement
|
|
|
Documenting Process Calibrator-HART Fluke 753
• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement
• HART Capabilities
|
|
|
Process Multimeter Fluke 787
• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool
|
|
|
Process Multimeter Fluke 789
• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool
• HART mode setting with loop power
|
|
|
Miliamp Process Clamp Meter Fluke 771
• 0 to 21 mA, 10 to 50 mA Current measure
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
|
|
|
Miliamp Process Clamp Meter Fluke 772
• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
|
|
|
Miliamp Process Clamp Meter Fluke 773
• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
• 0 to 30 V DC Voltage measure
• 0 to 10 V DC Voltage source
|