Digital Multifunction VDE Multimeter HT Italia M74

Code: HT Italia M74


 

Datasheet PDF, 0.42 Mb

Description

SAFETY TEST SECTION

  • Continuity test of protective conductors with 200mA
  • Insulation Resistance with 250, 500VDC
  • Trip-out time of RCDs type AC Standard
  • Test current selectable; 30mA, 30x5mA, 100mA, 300mA
  • Global Earth Resistance without RCD tripping
  • Global Earth Resistance with 0.1Ohm resolution
  • AUTOTEST function: automatic test of Global Earth Resistance + RDC test + Insulation test

 

MULTIMETER SECTION

  • DC Voltage
  • AC TRMS Voltage
  • Automatic detection of AC/DC signals
  • AC TRMS Current with optional clamp
  • AC TRMS Leakage current with optional clamp
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with optional clamp
  • Phase sequence with 1 or 2 wires method
  • Phase coincidence with 1 or 2 wires method
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Auto Power OFF
 

Standard accessories

  • C2075: two safety banana  + Shuko plug cable
  • KIT0075: kit of 2 Test leads + 2 alligator clips
  • BORSA75: Carrying bag
  • Calibration Certificate ISO9000
  • Instruction manual
  • Warranty card
 

Recommended options

  • HT4003: 400A AC clamps
  • HT96U: leakage current clamp 1-100-1000A/1V 5 4mm max diameter
  • NOCANBA: adaptor for connection HT96U clamp
 

More products HT

INSULATION CONTINUITY MEGOHMMETER AND DIGITAL MULTIMETER HT ITALIA M72

• Insulation Resistance with 250, 500VDC
• Measurement range up to 1GOhm
• Automatic discharging object after test
• Continuity test of protective conductors with 200mA
• DC Voltage
• AC TRMS Voltage

 

HT GSC60 MULTIFUNCTION ELECTRICAL INSTALLATION TESTER WITH POWER QUALITY ANALYSIS

• Insulation with voltage 50, 100, 250, 500, 1000VDC
• Three-phase Power quality and Energy consumption analysis
• 632 parameters can be recorded for over two months
• Voltage/current vector diagram
• Voltage/current waveforms
• Tables or histograms of Harmonics and THD%
• Integrated WiFi connection and compatibility with HTANALYSIS App

 

MULTIFUNCTION PORTABLE MULTIMETER FOR EARTH RESISTANCE MEASUREMENT HT ITALIA M73

• Trip out time measure on AC Standard RCD's
• Trip out current: 30, 30x5, 100, 300mA
• Global Earth Resistance with 0.1Ohm resolution
• Global Earth Resistance without RCD's tripping
• DC Voltage
• AC TRMS Voltage
• Automatic detection of AC/DC signals

 

AUDIO ANALYZER CLASS 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC

 

DIGITAL PROGRAMMABLE PROFESSIONAL MEGOHMMETER 10TOHM 5KV HT ITALIA HT7051

• Insulation resistance measurement with test voltage up to 5kVDC
• Measurement range up to 10Tohm
• Polarization Index (P.I.) measurement
• Dielectric Absorption Ratio (D.A.R) measurement
• RS-232 interface for PC connection
• Rechargeable internal battery

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

ENVIRONEMENTAL MULTIFUNCTION TESTERS HT ITALIA

• Air temperature (°C/°F)
• Air relative humidity (%RH)
• Air speed (m/S)
• Air volume (m3/s)
• Capacity measurements (kW)
• Temperature dew point measurement

 

HT8100 PROFESSIONAL PROCESS CALIBRATOR WITH MULTIMETER FUNCTIONS

• TRMS
• AC/DC voltage 1000V AC+DC
• AC/DC current 1A AC+DC
• DC 4-20mA current measurement
• DC 0-10V voltage measurement
• DC 4-20mA current generation

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A