Insulation and Continuity Resistance Tester for medical rooms HT Italia Equitest5070
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia Equitest5070


 

Datasheet PDF, 0.3 Mb

Description

  • Continuity of earth conductors with <12VAC and >10A test current
  • Voltage drop measure
  • 4-wire method without test leads calibration
  • Wide LCD Custom display
  • Save measured results
  • Recall saved dates at display
  • RS-232 serial port for PC connection
 

Standard accessories

  • C7000: set 2 cables with alligator clips, 3m
  • C2032-2MM: power supply cord
  • WP1991N: carrying bag
  • ISO 9000 calibration certificate
  • User manual
 

Recommended options

  • TOPVIEW: Windows software + RS-232 serial cable C232NG1
  • 1066-IECN: connector for banana cable 4mm, black
  • 1066-IECR: connector for banana cable 4mm, red
 

More products HT ITALIA

GSC60 MULTIFUNCTION TESTER FOR ELECTRICAL SAFETY TESTS AND POWER QUALITY ANALYSIS

• LECTRICAL SAFETY TESTING CEI 64-8
• Earth Resistance with voltammetric method with 2 or 3 points in TT, TN and IT systems
• NETWORK AND ENERGY CONSUMPTION ANALYSIS
• Measurement and recording of electrical parameters
• Voltages, Currents, Powers, Energies, cosphi, etc. in Single-phase and Three-phase systems

 

INSULATION CONTINUITY MEGOHMMETER AND DIGITAL MULTIMETER HT ITALIA M72

• Insulation Resistance with 250, 500VDC
• Measurement range up to 1GOhm
• Automatic discharging object after test
• Continuity test of protective conductors with 200mA
• DC Voltage
• AC TRMS Voltage

 

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A

 

HT I-V500W PHOTOVOLTAIC SYSTEM ANALYZER WITH I-V CURVE TRACER 1500V 15A

• I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems.
• Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/10A
• Measurement of open-circuit voltage and short-circuit current Voc/Isc
• Database of 30.000 selectable photovoltaic modules

 

PROFESSIONAL MULTIMETER CABLE VERIFIER FOR LAN VDE CHECKING HT ITALIA M75

• DC Voltage
• AC TRMS Voltage
• Continuity test of protective conductors with 200mA
• Insulation Resistance measurement with 500VDC
• Global Earth Resistance without RCD tripping
• Test executed on twisted pairs cables UTP and STP with RJ45 connector
• Quickly selection of cables pairs