Fluke 289 Handheld Digital Data Logging Multimeter 4.5 digit

Code: Fluke 289


 

Datasheet PDF, 0.16 Mb

Description

  • 4.5 digit large ¼ VGA display with white backlight
  • 50,000 count
  • 0.025% basic accuracy
  • Logging function with TrendCapture
  • Low input impedance function (LoZ)
  • Motor winding and low ohm measurement range
  • Low pass filter
  • Log multiple sessions or log data continuously for over 200 hours
  • i-info button on board help screens for measurement functions
  • Saved measurements allow you to name and recall measurements made in the field
  • Multiple sets of measurement information can simultaneously displayed at the same time.
  • Real Time Clock - for automatic time stamping of saved readings
  • Field upgradeable and expandable meter lets you stsay current as new capabilities are added
  • Multi-lingual interface
  • Min/Max/Average with Time Stamp to record signal fluctuations
  • Soft keys, scroll buttons and easy navigation control access to secondary functions.
  • 100 kHz ac bandwidth
  • True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads
  • Measure up to 10A (20 A for 30 seconds; 10A continuous)
  • 100 mF capacitance range
  • Temperature function
  • Relative mode to remove test lead resistance from low ohms or capacitance measurements
  • Peak capture to record transients as fast as 250 µs
  • Premium test leads and alligator clips included
  • Optical USB PC communication interface
  • Limited lifetime warranty
  • CAT III 1000 V / CAT IV 600 V safety rated
 
 
 

Standard accessories

  • Manual
  • 6 AA Batteries, installed
  • TL71 Silicone Test Leads
  • Probe Holder
  • Two AC72 Alligator Clips
  • Registration Card
  • Cal Practices Document
  • CD-ROM Users' Manual (16 languages)
  • Getting Started Manual
  • Statement of Calibration Practices Document
 

More products FLUKE

INFRARED DIGITAL THERMOMETER FLUKE 62

• High-resolution optics
• High accuracy: 1 % and repeatability: 0.5 %
• MAX temperature display
• Laser targeting
• Backlit display
• Expanded measurement range up to 535 °C (999 °F)

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 744

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging
• Integrated HART communication

 

FLUKE TI200 INFRARED CAMERA 200X150 RESOLUTION

• 200x150 Detector resolution
• Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
• Range: -20 °C si +650 °C
• Precision : ± 2 °C sau 2%
• Sensibility : = 0,075 °C

 

POWER QUALITY CLAMP METER FLUKE 345

• 2000A AC/DC current
• 600 V CAT IV power analyzer
• Data logging
• Troubleshoot harmonics
• Inrush current

 

INFRARED NON-CONTACT THERMOMETER FLUKE 61

• Bright laser beam provides easy targeting
• Display clearly supplies data at a glance
• Shock-absorbing holster increases ruggedness
• 0.2 °C (0. 5 °F) resolution up to 275 °C (525 °F)
• Backlight illuminates the screen in the dark
• Automatic sleep mode after 7 seconds extends battery life
• Alkaline batteries provide 4000 typical measurements

 

CURRENT CLAMP METER TRUE-RMS 600 A FLUKE 373

• 600 A AC current measurement with fixed jaw
• 600 V AC and DC voltage measurement
• True-rms ac voltage and current
• 6000 O resistance measurement
• 1000 µF capacitance measurement

 

FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

• 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
• 0.1 % basic accuracy (0.05 % for PM 6304C)
• Easy to use, at-a-glance display

 

INFRARED NON-CONTACT THERMOMETER FLUKE 572

• Backlit display for poorly lit areas
• Last ten temperature readings displayed on bar graph for easy reference
• Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
• Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
• MIN/MAX measurements calculations instantly computed
• Audible and visible HI temperature alarm for instant recognition

 

INFRARED THERMOMETER WITH CONTACT THERMOCOUPLE FLUKE 561 HVAC PRO

• IR Thermometer with K-type thermocouple capability
• IR thermometer for quick measurements up close, or at a distance, without a ladder
• Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
•  Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
• Single-point laser sighting
• Temperature range of -40 °C to 550 ° C (-40 °F to 1022 °F) covers most industrial and residential applications

 

THERMOCOUPLE TEMPERATURE CALIBRATOR FLUKE 714

• -200 to 1800ēC Range Measure / simulate thrmocouple
• -10 to 75 mV Range Measure / simulate voltage
• Measure temperature from TC output