Voltage Detector Fluke LVD2 Volt Light

Code: Fluke LVD2 Volt Light


 

Datasheet PDF, 0.26 Mb

Description

  • Dual Sensitivity
  • LED light with 100,000 hour life
  • Detects from 90 to 600 V AC
  • Rated to CAT IV 600 V
  • Dual Levels of Detection
  • Blue indicates proximity to AC Voltage source
  • Red indicates you’re at the source
  • Operating temperature 0 deg C to 50 deg C
  • Ultra-Bright White LED
  • 100,000 hr bulb
  • AAA battery included
 

Recommended options

 

 

More products FLUKE

DOCUMENTING PROCESS CALIBRATOR-HART FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement
• HART Capabilities

 

INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

FLUKE TIX500 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

FLUKE TIS10 INFRARED CAMERA 80X60

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

PORTABLE VIBRATION TESTER ANALYZER FLUKE 810

• On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime
• Fault severity scale with four severity levels helps you prioritize maintenance work
• Repair recommendations advise technicians on corrective action
• On-board context sensitive help provides real-time tips and guidance to new users
• 2 GB expandable on-board memory provides enough space for your machinery’s data

 

FLUKE 83V HANDHELD DIGITAL MULTIMETER 3.75 DIGIT

• 3.75 digit
• 6000 count resolution
• 0.1% basic accuracy

 

FLUKE 700PTP-1 PNEUMATIC TEST PUMP FOR PRESSURE CALIBRATION

• Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
• ¼ -NPT female fitting for the reference gauge or pressure module
• ¼" NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke

 

FLUKE TOPAS 1760 THREE PHASE POWER QUALITY RECORDER

• 8 input channels
• Fully IEC 61000-4-30 Class-A standard compliant
• Power quality statistics according to EN50160, DISDIP tables, ITIC, CEBEMA, ANSI
• 10 MHz, 6000 Vpk waveform capture
• GPS time synchronization
• records rms, min, max values for: Voltage Current Power P, Q, S Power Factor kWh Flicker Unbalance Frequency Harmonics Interharmonics

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

FLUKE 1623-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• Rugged carrying case
• USB data storage and transfer