Multifunction Process Calibrator Fluke 726

Code: Fluke 726


 

Datasheet PDF, 0.53 Mb

Description

  • 0 to 100 mV, 0 to 30 V DC Voltage measure
  • 0 to 100mV, 0 to 20 V DC Voltage source / simulate
  • 0 to 24 mA Current measure / source / simulate
  • 0 to 4000 O Resistance measure / source / simulate
  • 1 to 15 kHz Frequency measure / source / simulate
  • More precise measurement and calibration source performance, accuracies of 0.01%.
  • Two separate channels; measure, source and view process signals simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters
  • Measure or source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Integrated pressure switch test allows you to capture the set, reset and deadband of a switch
  • Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis
  • Transmitter error% calculation, interpret calibration results without a calculator
  • Perform fast linearity tests with auto step and auto ramp features
  • Power transmitters during test using 24 V loop supply and simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing
  • HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation
  • Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement.
  • New voltage input protection design for improved reliability
  • Three-year warranty
 

Standard accessories

  • One set of AC72 alligator clips
  • One set of stackable test leads
  • One set of TL 75 testleads
  • User manuals
  • NIST- traceable calibration report and data
 

More products FLUKE

PROCESS MULTIMETER FLUKE 789

• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool
• HART mode setting with loop power

 

FLUKE 28 II HANDHELD MULTIMETER RUGGED IP67 INDUSTRIAL 4.5 DIGIT

• 4.5 digit
• 20,000 count resolution for precise measurements
• 0.05% basic accuracy
• New - IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
• Peak min-max
• True-rms ac voltage and current for accurate measurements on non linear signals
• Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument

 

FLUKE 435 II THREE PHASE POWER QUALITY ANALYZER

• Power inverter efficiency: Simultaneously measure AC output power and DC input power
• PowerWave data capture: Capture fast RMS data, show half-cycle and waveforms
• Energy loss calculator
• Troubleshoot real-time
• Highest safety rating in the industry
• Measure all three phases and neutral

 

FLUKE TIS50 INFRARED CAMERA 220X165

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

INFRARED NON-CONTACT THERMOMETER FLUKE 572

• Backlit display for poorly lit areas
• Last ten temperature readings displayed on bar graph for easy reference
• Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
• Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
• MIN/MAX measurements calculations instantly computed
• Audible and visible HI temperature alarm for instant recognition

 

VOLTAGE CONTINUITY TESTER FLUKE T100

• Display: 12 LED's
• Voltage test
• Optical and acoustical continuity test

 

FLUKE II500 ACOUSTIC CAMERA FOR DETECTION AND INSPECTION OF COMPRESSED GAS LEAKS

• Easy, fast, and safe visual detection of compressed gas leaks.
• The 7" LCD touchscreen displays a SoundMap™ over visual images, making it easier to locate leaks quickly.
• Intuitive interface requires no training for maintenance teams.

 

FLUKE 1587 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

• Insulation test: 0.01 MO to 2 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

HANDHELD LOOP CALIBRATOR FLUKE 707EX

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%
• For use in explosion endangered areas ATEX certifed ( II 2 G Eex ia IIC T4)

 

FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.