Handheld Loop Calibrator Fluke 707Ex

Code: Fluke 707Ex


 

Datasheet PDF, 0.53 Mb

Description

  • 0 to 28 V DC Voltage measure
  • 0 to 24 mA Current measure
  • 0 to 20 mA Current source / simulate
  • mA accuracy of 0.015%, superior to other loop calibrators in this price range
  • For use in explosion endangered areas ATEX certifed (  II 2 G Eex ia IIC T4)

  • Large display and simple, quick-click interface for easy one-handed operation
  • Simultaneous mA and % readout for quick, easy interpretation of readings
  • 1 µA resolution for mA source, simulate and measure
  • Push button 25% steps for fast, easy linearity checks
  • 0-100% "span check" for fast confirmation of zero and span
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
  • Single 9V battery that is easily changed without braking calibration seal
  • 0 - 20 mA or 4 - 20 mA default start up modes
  • Innovative output adjustment dial with 1 µA and 100 resolution
  • HART ™ mode connects 250 O resistor in series with 24 V loop for compatibility with HART communicators
 

Standard accessories

  • AC70A Alligator Clips
  • C10 protective yellow holster with Flex-Stand™
  • Instruction sheet
  • TL75 safety-designed test lead set
  • NIST- traceable calibration report and data
 

More products FLUKE

FLUKE TOPAS 1760 THREE PHASE POWER QUALITY RECORDER

• 8 input channels
• Fully IEC 61000-4-30 Class-A standard compliant
• Power quality statistics according to EN50160, DISDIP tables, ITIC, CEBEMA, ANSI
• 10 MHz, 6000 Vpk waveform capture
• GPS time synchronization
• records rms, min, max values for: Voltage Current Power P, Q, S Power Factor kWh Flicker Unbalance Frequency Harmonics Interharmonics

 

DIGITAL PYROMETER FLUKE 63

• Single point offset laser sighting
• Best accuracy in its class: + 1% of reading
• Holds temperature readings for 7 seconds
• Dual displays shows current and MAX measurements simultaneously
• Backlit display for poorly lit areas
• Wide temperature range from -30º to 500ºC (-20º to 932ºF)

 

FLUKE 1630 EARTH GROUND CLAMP METER

• resistance range from 0.025 O to 1500 O
• large jaw opening of 35 mm
• ground leakage current, from 0.2 mA to 1000 mA
• ac current measurement range from 0.2 A to 30 A

 

FLUKE 115 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• AC/DC Current
• Capacitance and Frequency

 

FLUKE 190-102 190-102/S HANDHELD DIGITAL OSCILLOSCOPE 2X100 MHZ

• 2-channels isolated 100MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

FLUKE 190-104 190-104/S HANDHELD SCOPEMETER OSCILLOSCOPE 4X100 MHZ

• 4-channels isolated 100MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

PRECISION INFRARED THERMOMETER FLUKE 574

• Backlit display for poorly lit areas
• Last ten temperature readings displayed on bar graph for easy reference
• Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
• Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
• MIN/MAX measurements calculations instantly computed
• Audible and visible HI temperature alarm for instant recognition
• 100 temperature data logging capability for easy route review

 

FLUKE 175 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count resolution
• 0.15% basic accuracy
• True RMS voltage and current measurements

 

FLUKE TIX560 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

FLUKE 1652C MULTIFUNCTION INSTALLATION TESTER 250V-1000V

• Test voltage: 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results