Fluke 1750 Three Phase Power Logger

Code: Fluke 1750 1750-Basic


 

Datasheet PDF, 0.6 Mb

Description

  • Power quality that meets the standard: comply with IEC61000-4-30 standards for voltage, current, power, harmonics, flicker etc.
  • 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events
  • 5 MHz Transient Voltage
  • Quick and reliable configuration: PDA wireless "front panel interface provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations
  • Threshold-free set up: Apply thresholds after data is collected with Fluke Power Analyze Software - no need to worry about missed information due to incorrect setups
  • Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time
  • Intuitive PC software: automated EN50160 reporting and compliance
  • Reporting has never been easier: Auto Report creates either standard reports or customized reports with the minimum effort or hassle. 
  • Plug and play: Set up in minutes with self-identifying current probes and single-lead voltage connections
  • No need to reconnect wires: Swap channels internally with the wireless PDA or PC when connections are not correct
  • Measure every parameter: Voltage and current on three phases, neutral, and ground
  • Quickly retrieve data: included SD memory card
  • 100BaseT high-speed Ethernet connection
 

Standard accessories

Fluke 1750/B include:
  • 1750 acquisition unit
  • PDA wireless "front panel interface" and charger power plug adapters
  • 5 Test leads and clips
  • SD memory card
  • Fluke Power View and Fluke Power Analyze software
  • Power cord with international plug set
  • Ethernet cable
  • Color localization set
  • Printed Getting Started manual
  • Product CD with software and user manual PDF
  • CS 1750/1760 Rugged transit softcase
Fluke 1750 also include:
  • 4 x 400A current probes (3140)
 

Recommended options

Current clamps

3005-PR

Model 3005R CT

3014-PR

40 A Clamp-on CT

3110-PR

100 A Flexi-CT (60 cm)

3210-PR

1000 A Flexi-CT (60 cm)

3310-PR

5000 A Flexi-CT (60 cm)

3312-PR

5000 A Flexi-CT (120 cm)

 

More products FLUKE

FLUKE 1730 THREE-PHASE ENERGY LOGGER

• Key measurements: Voltage, current, power, power factor and associated values
• Bright, color touch screen
• Two USB ports
• Compact size: designed to fit in tight spaces and panels.
• Highest safety rating in the industry
• Energy analyze application software


DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 374

• iFlex fexible current probe compatible
• 600 A AC and DC current measurement with fxed jaw
• 2500 A AC current measurement with iFlex (sold separately)
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• 6000 O resistance measurement
• 1000 µF capacitance measurement

 

FLUKE VR1710 SINGLE PHASE VOLTAGE QUALITY RECORDER

• 70 V to 300 V Operating Voltage
• Fast and easy recording of voltage trends, dropouts, and power quality
• Continuous recording of all values with no gaps
• Flicker recording to EN 61000-4-15, individual harmonic and THD values
• Min, Max, and Average RMS values


MILIAMP PROCESS CLAMP METER FLUKE 773

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
• 0 to 30 V DC Voltage measure
• 0 to 10 V DC Voltage source

 

WIRELESS AC CURRENT MEASUREMENT KIT FLK-CNX I3000 IFLEX KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• Memory recording up to 65,000 readings
• CAT III 1000, CAT IV 600 V; IP42


MULTIFUNCTION PROCESS CALIBRATOR FLUKE 725

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

FLUKE TI200 INFRARED CAMERA 200X150 RESOLUTION

• 200x150 Detector resolution
• Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
• Range: -20 °C si +650 °C
• Precision : ± 2 °C sau 2%
• Sensibility : = 0,075 °C

 

FLUKE ESA712 ELECTRO-SECURITY ANALYZER FOR MEDICAL EQUIPMENTS

• 5” Touchscreen with intuitive user interface
• Small, portable, ergonomic design with an integratedhandle
• Ten applied parts posts with innovative LED lighting guidance (ECG & Banana)
• Insulation resistance from 50V, 100V, 250V and 500V

 

FLUKE 1653B MULTIFUNCTION INSTALLATION TESTER 50V-1000V

• Test voltage: 50V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance