Documenting Process Calibrator Fluke 744

Code: Fluke 744


 

Datasheet PDF, 0.13 Mb

Description

  • 0 to 300 V DC/AC Voltage measure
  • 0 to 15 V DC Voltage source / simulate
  • 0 to 110 mA DC Current measure
  • 0 to 22 mA DC Current  source / simulate
  • 0 to 11 kO Resistance measure / source / simulate
  • 1 to 50 kHz Frequency measure / source / simulate
  • PC interface and data logging
  • Integrated HART communication functions, permitting you to monitor, control, and calibrate HART instrumentation

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Measure and source simultaneously with one compact, rugged, reliable tool
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white display. Read both sourced and measured parameters
  • Multi lingual interface
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1msec.
 

Standard accessories

  • BC7217 battery charger
  • BP7217 battery pack
  • Instruction manual
  • NIST-traceable calibration report and data
  • One set of TP220 test probes
  • Two sets of AC220 test clips
  • Two sets of TL224 industrial test leads
 

More products FLUKE

VIBRATION METER FLUKE 805

• measures overall vibration as well as specific variables like bearing condition and temperature
• calculate bearing condition and overall vibration
• Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz)
• Exportable data via USB
• Crest Factor+

 

INTRINSICALLY SAFE PRESSURE CALIBRATOR FLUKE 718

• ATEX II 1G Ex ia IIC T4 Compliant
• Built-in pressure / vacuum hand pump
• Pressure measurement to 0.05%
• Pressure measurement to 200

 

FLUKE 700PTP-1 PNEUMATIC TEST PUMP FOR PRESSURE CALIBRATION

• Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
• ¼ -NPT female fitting for the reference gauge or pressure module
• ¼" NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke

 

FLUKE 1507 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

• Insulation test range: 0.01 MO to 10 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

FLUKE VT04 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 28° X 28°
• 4 GB Micro SD card

 

HANDHELD LOOP CALIBRATOR FLUKE 707

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%

 

FLUKE 700G/TRACK DATALOGGING SOFTWARE FOR 700G PRESSURE GAUGES

• Precision pressure measurement from -20 mbar to 690 bar
• Absolute pressure measurement ranges 15, 30, 100, 300 psia
• Accuracy to 0.05 % of full scale
• Reference class gauge accuracies to 0.04 % of reading
• Easy to use, rugged construction for reliable performance

 

MILIAMP PROCESS CLAMP METER FLUKE 772

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity

 

FLUKE 700G PRECISION PRESSURE TEST GAUGE

• Precision pressure measurement from -20 mbar to 690 bar
• Absolute pressure measurement ranges 15, 30, 100, 300 psia
• Accuracy to 0.05 % of full scale
• Reference class gauge accuracies to 0.04 % of reading
• Easy to use, rugged construction for reliable performance

 

FLUKE TIX560 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C