Documenting Process Calibrator Fluke 741B

Code: Fluke 741B


 

Datasheet PDF, 0.13 Mb

Description

  • 0 to 300 V DC/AC Voltage measure
  • 0 to 15 V DC Voltage source / simulate
  • 0 to 110 mA DC Current measure
  • 0 to 22 mA DC Current  source / simulate
  • 0 to 11 kO Resistance measure / source / simulate
  • 1 to 50 kHz Frequency measure / source / simulate
  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Measure and source simultaneously with one compact, rugged, reliable tool
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white display. Read both sourced and measured parameters
  • Multi lingual interface
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1msec.
 

Standard accessories

  • BC7217 battery charger
  • BP7217 battery pack
  • Instruction manual
  • NIST-traceable calibration report and data
  • One set of TP220 test probes
  • Two sets of AC220 test clips
  • Two sets of TL224 industrial test leads
  •  

    More products FLUKE

    FLUKE 719PRO ELECTRIC PRESSURE CALIBRATOR

    • Fluke-719Pro-30G -12 to 30 PSI / -0.8 to 2 bar
    • Fluke-719Pro-150G -12 to 150 PSI / -0.8 to 10 bar
    • Fluke-719Pro-300G -12 to 300 PSI / -0.8 to 20 bar
    • Unique integrated electric pump for one handed pressure calibration
    • Pressure measurement from internal or external sensor
    • Sourced/simulated or measured mA values
    • Temperature measured by optional RTD probe

     

    HVAC CURRENT CLAMP METER 600 A FLUKE 902

    • Designed for HVAC applications
    • capacitance, DC Current (µA), and temperature measurements
    • Small body and jaws

     

    FLUKE NORMA 5000 PRECISION POWER ANALYZER

    • 3, 4 or 6 power phases
    • Bandwidth from dc to 3 MHz / 10 MHz
    • FFT analysis, vector diagram, and Digital Oscilloscope
    • Voltage, current and power harmonics measured up to the 40th harmonic

     

    FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

    • Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
    • LeakQâ„¢ Mode: Estimated leak size and cost.
    • PDQ Modeâ„¢: Assesses discharge severity.
    • MecQâ„¢ Mode: Proactively address potential problems in rotating mechanical components.
    • Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
    • Wireless Upload: Easily transfer data to Fluke Connect.

     

    VOLTAGE CONTINUITY TESTER FLUKE T140

    • Resistance measurement
    • Backlight
    • LED Bargraph
    • Display: 3½ digit LCD
    • Voltage test
    • Optical and acoustical continuity test

     

    FLUKE 700LTP-1 LOW-PRESSURE VACUUM TEST PUMP

    • hand operated pressure pump
    • designed to generate either vacuum to -13 psi / -.90 bar or pressures to 100 psi / 6.9 bar
    • Pump can be easily cleaned without disassembly
    • Adjustable pressure relief valve with slow-bleed capability. Allows the slow release pressure at a controlled rate
    • Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
    • Slim design, easy to carry and use

     

    WIRELESS AC VOLTAGE MODULE FLUKE CNX V3000

    • True-RMS AC voltage measurements to 1000V
    • ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
    • Memory recording up to 65,000 readings
    • Backlit LCD display
    • CAT IV 600 V, CAT III 1000 V; IP42


    FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

    • 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
    • 0.1 % basic accuracy (0.05 % for PM 6304C)
    • Easy to use, at-a-glance display

     

    MILIAMP PROCESS CLAMP METER FLUKE 773

    • 0 to 24 mA Current measure / source / simulate
    • Best in class 0.2 % accuracy
    • 0.01 mA resolution and sensitivity
    • 0 to 30 V DC Voltage measure
    • 0 to 10 V DC Voltage source

     

    RTD TEMPERATURE CALIBRATOR FLUKE 712

    • -200 to 800ºC Range Measure / simulate RTD (Pt 100)
    • 0 to 3200 O Range Measure / simulate resistance
    • 0.1 O, 0.1 ºC Resolution