Code: Fluke 721 721-1601 721-1603 721-1605 721-1610 721-1630 721-1650 721-3601 721-3603 721-3605 721-3610 721-3615 721-3630 721-3650
Description
Pressure Calibration and Temperature Measurement for Custody Transfer Applications
The ideal tool for gas custody transfer applications is the Fluke 721 Precision Pressure Calibrator. With dual isolated pressure sensors, it allows you to take simultaneous static and differential pressure measurements with a single tool.
The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).
Standard accessories
Fluke-721-1601 Dual Sensor Pressure Calibrator, 16 PSIG, 100 PSIG
Fluke-721-1603 Dual Sensor Pressure Calibrator, 16 PSIG, 300 PSIG
Fluke-721-1605 Dual Sensor Pressure Calibrator, 16 PSIG, 500 PSIG
Fluke-721-1610 Dual Sensor Pressure Calibrator, 16 PSIG, 1000 PSIG
Fluke-721-1615 Dual Sensor Pressure Calibrator, 16 PSIG, 1500 PSIG
Fluke-721-1630 Dual Sensor Pressure Calibrator, 16 PSIG, 3000 PSIG
Fluke-721-1650 Dual Sensor Pressure Calibrator, 16 PSIG, 5000 PSIG
Fluke-721-3601 Dual Sensor Pressure Calibrator, 36 PSIG, 100 PSIG
Fluke-721-3603 Dual Sensor Pressure Calibrator, 36 PSIG, 300 PSIG
Fluke-721-3605 Dual Sensor Pressure Calibrator, 36 PSIG, 500 PSIG
Fluke-721-3610 Dual Sensor Pressure Calibrator, 36 PSIG, 1000 PSIG
Fluke-721-3615 Dual Sensor Pressure Calibrator, 36 PSIG, 1500 PSIG
Fluke-721-3630 Dual Sensor Pressure Calibrator, 36 PSIG, 3000 PSIG
Fluke-721-3650 Dual Sensor Pressure Calibrator, 36 PSIG, 5000 PSIG
Fluke-720RTD RTD Probe for 721 and 719Pro
Fluke-720URTDA Universal RTD adapter for Fluke-721 and 719Pro
• Soft case
• Four (4) AA batteries
• Manual
• Traceable calibration certificate
• Test leads
Recommended options
Fluke-720RTD RTD Probe for 721 and 719Pro
Fluke-720URTDA Universal RTD adapter for Fluke-721 and 719Pro
More products FLUKE
|
DIGITAL CONTACT THERMOMETERS SERIES FLUKE 50 II
• Relative time clock on MIN, MAX, and AVG provides a time reference for major events |
|
FLUKE 123B 123B/S INDUSTRIAL SCOPEMETER HAND-HELD OSCILLOSCOPE 2X20MHZ
• 2-channel 20MHz |
|
FLUKE ESA712 ELECTRO-SECURITY ANALYZER FOR MEDICAL EQUIPMENTS
• 5â€� Touchscreen with intuitive user interface
|
|
FLUKE TIS60 INFRARED CAMERA 260X195
• Fluke TiS10 80x60 pixels |
|
WIRELESS MEASUREMENT SYSTEM FLUKE CNX 3000 SERIES
• Fluke CNX 3000 Wireless Multimeter |
|
CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 353
• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC |
|
INFRARED THERMOMETER WITH CONTACT THERMOCOUPLE FLUKE 561 HVAC PRO
• IR Thermometer with K-type thermocouple capability |
|
FLUKE TI400 INFRARED CAMERA 320X240 RESOLUTION
• 320x240 Detector resolution |
|
HVAC CURRENT CLAMP METER 600 A FLUKE 902
• Designed for HVAC applications |
|
FLUKE 700G PRECISION PRESSURE TEST GAUGE
• Precision pressure measurement from -20 mbar to 690 bar |