Precision Dipole Antenna with Omni-directional Emissions for Immunity Testing 440..3010 MHz ETS-Lindgren 3125

Code: ETS-Lindgren 3125


 

Datasheet PDF, 0.08 Mb

Description

  • Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
  • IEEE SCC 34 Design
  • Designed for AAMI/FDA Test Requirements

 

Model

Frequency

Connectors

Impedance (Nominal)

Max Continuous Power

VSWR

3125-1610

1600 MHz - 1620 MHz

SMA

50 ?

10 W

<1.7:1

3125-1750

1710 MHz - 1785 MHz

SMA

50 ?

5 W

<1.7:1

3125-1840

1805 MHz - 1880 MHz

SMA

50 ?

5 W

<1.7:1

3125-1880

1850 MHz - 1910 MHz

SMA

50 ?

1 W

<1.7:1

3125-2450

2440 MHz - 2460 MHz

SMA

50 ?

1 W

< 1.7:1

3125-3000

2990 MHz - 3010 MHz

SMA

50 ?

1 W

<1.7:1

3125-450

440 MHz - 460 MHz

SMA

50 ?

20 W

<1.7:1

3125-600

590 MHz - 610 MHz

SMA

50 ?

20 W

<1.7:1

3125-870

824 MHz - 915 MHz

SMA

50 ?

10 W

<1.7:1

3125-950

935 MHz - 960 MHz

SMA

50 ?

10 W

<1.7:1

Physical Specifications Comparison

Model

Width

Depth

3125-2450

5.59 cm   (2.20 in)

3.3 cm   (1.30 in)

3125-1610

8.63 cm   (3.40 in)

3.3 cm   (1.30 in)

3125-1750

8.4 cm   (3.31 in)

3.3 cm   (1.30 in)

3125-1840

8.2 cm   (3.23 in)

3.3 cm   (1.30 in)

3125-1880

8.1 cm   (3.19 in)

3.3 cm   (1.30 in)

3125-3000

4.57 cm   (1.80 in)

3.3 cm   (1.30 in)

3125-450

31.24 cm   (12.30 in)

3.3 cm   (1.30 in)

3125-600

23.62 cm   (9.30 in)

3.3 cm   (1.30 in)

3125-870

18.2 cm   (7.17 in)

3.3 cm   (1.30 in)

3125-950

14.99 cm   (5.90 in)

3.3 cm   (1.30 in)

 

More products ETS-LINDGREN

BROADBAND LOG PERIODIC ARRAY ANTENNA 200 MHZ..5 GHZ ETS-LINDGREN 3147

• Frequency Minimum 200 MHz
• Frequency Maximum 5 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 80 W
• Pattern Type directional
• Peak Power 100.0 W
• VSWR 1.2:1

 

VLF MAGNETIC FIELD SURVEY METER 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 700 MHZ..10 GHZ ETS-LINDGREN 3164-08

• Frequency Minimum 700 MHz
• Frequency Maximum 10 GHz
• Cross Polarization Isolation >20 dB
• Impedance 50 ?
• Connector Input Power SMA Female (2)
• 700 MHz - 10 GHz Frequency Range
• Linear or Circular Polarization (With Hybrid)

 

LINEAR POLARIZED LOG PERIODIC HIGH POWER DUAL ARRAY ANTENNA 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2

 

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

BROADBAND LOG PERIODIC ANTENNA FOR CISPR 16-1 TEST 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

ACTIVE MONOPOLE RECEPTION ANTENNA 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge

 

HORIZONTAL/ VERTICAL ELECTRIC FIELD GENERATOR 10 KHZ..30 MZ ETS-LINDGREN 5502

• Generates vertical or horizontal electric field
• Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
• Fully Adjustable Height and Separation of Main Conductors
• Large Immunity Volume
• Chamber Supported