Code: ETS-Lindgren 3125
Description
|
Model |
Frequency |
Connectors |
Impedance (Nominal) |
Max Continuous Power |
VSWR |
|
3125-1610 |
1600 MHz - 1620 MHz |
SMA |
50 ? |
10 W |
<1.7:1 |
|
3125-1750 |
1710 MHz - 1785 MHz |
SMA |
50 ? |
5 W |
<1.7:1 |
|
3125-1840 |
1805 MHz - 1880 MHz |
SMA |
50 ? |
5 W |
<1.7:1 |
|
3125-1880 |
1850 MHz - 1910 MHz |
SMA |
50 ? |
1 W |
<1.7:1 |
|
3125-2450 |
2440 MHz - 2460 MHz |
SMA |
50 ? |
1 W |
< 1.7:1 |
|
3125-3000 |
2990 MHz - 3010 MHz |
SMA |
50 ? |
1 W |
<1.7:1 |
|
3125-450 |
440 MHz - 460 MHz |
SMA |
50 ? |
20 W |
<1.7:1 |
|
3125-600 |
590 MHz - 610 MHz |
SMA |
50 ? |
20 W |
<1.7:1 |
|
3125-870 |
824 MHz - 915 MHz |
SMA |
50 ? |
10 W |
<1.7:1 |
|
3125-950 |
935 MHz - 960 MHz |
SMA |
50 ? |
10 W |
<1.7:1 |
|
Model |
Width |
Depth |
|
3125-2450 |
5.59 cm (2.20 in) |
3.3 cm (1.30 in) |
|
3125-1610 |
8.63 cm (3.40 in) |
3.3 cm (1.30 in) |
|
3125-1750 |
8.4 cm (3.31 in) |
3.3 cm (1.30 in) |
|
3125-1840 |
8.2 cm (3.23 in) |
3.3 cm (1.30 in) |
|
3125-1880 |
8.1 cm (3.19 in) |
3.3 cm (1.30 in) |
|
3125-3000 |
4.57 cm (1.80 in) |
3.3 cm (1.30 in) |
|
3125-450 |
31.24 cm (12.30 in) |
3.3 cm (1.30 in) |
|
3125-600 |
23.62 cm (9.30 in) |
3.3 cm (1.30 in) |
|
3125-870 |
18.2 cm (7.17 in) |
3.3 cm (1.30 in) |
|
3125-950 |
14.99 cm (5.90 in) |
3.3 cm (1.30 in) |
More products ETS-LINDGREN
|
PRECISION DIPOLE ANTENNA WITH OMNI-DIRECTIONAL EMISSIONS FOR IMMUNITY TESTING 440..3010 MHZ ETS-LINDGREN 3125
• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz |
|
RESONANT DIPOLE ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3121D
• Frequency Minimum 30 MHz |
|
LINE IMPEDANCE STABILIZATION NETWORK ETS-LINDGREN
• Insulated Plugs for Safer Power Connections |
|
BROADBAND E-FIELD MONITORING SYSTEM 10 KHZ..40 GHZ ETS-LINDGREN HI-6100 E-FIELD MONITOR
• HI-6100 Field Monitor with 4 Probe Input Channels |
|
CURRENT MEASUREMENT PROBES 10 KHZ..1000 MHZ ETS-LINDGREN
• 10 kHz..1000 MHz Frequency ranges |
|
PROTECTION FILTERS FOR TEMPEST/ RFI/ EMI DIGITAL ANALOG DATA TRANSMISSIONS ETS-LINDGREN N2460
• Suitable for EMI and Tempest Protection |
|
HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X
• Current Rating 2 Amps |
|
RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230
• Standard dimenssions 600 x 500 x 500 mm |
|
POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X
• Current Rating 6 Amps |
|
DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B
• Frequency Minimum 200 MHz |