Precision Dipole Antenna with Omni-directional Emissions for Immunity Testing 440..3010 MHz ETS-Lindgren 3125

Code: ETS-Lindgren 3125


 

Datasheet PDF, 0.08 Mb

Description

  • Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
  • IEEE SCC 34 Design
  • Designed for AAMI/FDA Test Requirements

 

Model

Frequency

Connectors

Impedance (Nominal)

Max Continuous Power

VSWR

3125-1610

1600 MHz - 1620 MHz

SMA

50 ?

10 W

<1.7:1

3125-1750

1710 MHz - 1785 MHz

SMA

50 ?

5 W

<1.7:1

3125-1840

1805 MHz - 1880 MHz

SMA

50 ?

5 W

<1.7:1

3125-1880

1850 MHz - 1910 MHz

SMA

50 ?

1 W

<1.7:1

3125-2450

2440 MHz - 2460 MHz

SMA

50 ?

1 W

< 1.7:1

3125-3000

2990 MHz - 3010 MHz

SMA

50 ?

1 W

<1.7:1

3125-450

440 MHz - 460 MHz

SMA

50 ?

20 W

<1.7:1

3125-600

590 MHz - 610 MHz

SMA

50 ?

20 W

<1.7:1

3125-870

824 MHz - 915 MHz

SMA

50 ?

10 W

<1.7:1

3125-950

935 MHz - 960 MHz

SMA

50 ?

10 W

<1.7:1

Physical Specifications Comparison

Model

Width

Depth

3125-2450

5.59 cm   (2.20 in)

3.3 cm   (1.30 in)

3125-1610

8.63 cm   (3.40 in)

3.3 cm   (1.30 in)

3125-1750

8.4 cm   (3.31 in)

3.3 cm   (1.30 in)

3125-1840

8.2 cm   (3.23 in)

3.3 cm   (1.30 in)

3125-1880

8.1 cm   (3.19 in)

3.3 cm   (1.30 in)

3125-3000

4.57 cm   (1.80 in)

3.3 cm   (1.30 in)

3125-450

31.24 cm   (12.30 in)

3.3 cm   (1.30 in)

3125-600

23.62 cm   (9.30 in)

3.3 cm   (1.30 in)

3125-870

18.2 cm   (7.17 in)

3.3 cm   (1.30 in)

3125-950

14.99 cm   (5.90 in)

3.3 cm   (1.30 in)

 

More products ETS-LINDGREN

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION WITH LOW EARTH LEAKAGE CURRENTS 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

FIELD GENERATING PYRAMIDAL HORN ANTENNA FOR EMC AUTOMOTIVE TESTING ES-XW7T-1A278-AC 2.7..3.1 GHZ ETS-LINDGREN 3162-02

• Frequency Minimum 2.7 GHz
• Frequency Maximum 3.1 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Polarization linear
• Meets Specs for ES-XW7T-1A278-AC

 

ELECTROMAGNETIC LEAKAGE METER OF MICROWAVE OVENS ETS-LINDGREN HI-1600

• Calibrated at 915 MHz and 2450 MHz
• Three Ranges

 

HIGH GAIN CONICAL HORN ANTENNA WITH LINEAR POLARIZATION 4..26.5 GHZ ETS-LINDGREN 3163

• Conical Shape
• Series Frequency Range: 4 GHz to 26.5 GHz
• High Gain
• Low VSWR

 

REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

HIGH CURRENT POWER RFI/EMI PROTECTION FILTERS IN SINGLE PHASE NETWORK 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

PROTECTION TEMPEST/ RFI/ EMI FILTERS FOR TELECOM ETS-LINDGREN N24X/ N29X

• Suitable for EMI, EMP and Tempest protection
• Tubular, flat-pack or modular design
• 100dB insertion loss
• New ISDN filters now available
• Matched to balanced 600 Ohm lines