Line Impedance Stabilization Network ETS-Lindgren

Code: ETS-Lindgren


 

Description

  • Insulated Plugs for Safer Power Connections
  • Coils Matched for Application
  • Individually Calibrated
  • One Piece, Multi-Line Design for Convenience

 

 

Model

Frequency

Maximum Voltage

3625-2  

100 kHz - 65 MHz

400 VAC Line - Line 220 VAC Line to Ground

3701  

10 kHz - 30 MHz

250 VAC

3725-2M  

10 kHz - 100 MHz

220 VAC Line to Ground

3810-2  

9 kHz - 30 MHz

 

3816-2  

9 kHz - 30 MHz

 

3850-2  

9 kHz - 100 MHz

220 VAC Line to Ground 400 VAC Line - Line

3925-2  

5 kHz - 1000 MHz

400 VAC Line - Line 220 VAC Line to Ground

4825-2  

9 kHz - 30 MHz

 

 

More products ETS-LINDGREN

PORTABLE TEST ENCLOSURE FOR EMI/RFI TEST ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

DOUBLE-RIDGET HORN ANTENNA FOR EMC MEASUREMENTS 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

WIRELESS INTERFACE TEST SYSTEM FOR MOBILE PHONE TESTING IN CELLULAR COMMUNICATIONS ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

VLF MAGNETIC FIELD SURVEY METER 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

DUAL POLARIZED LOG PERIODIC ARRAY ANTENNA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized

 

LINE IMPEDANCE STABILIZATION NETWORK ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience


PRECISION DIPOLE ANTENNA WITH OMNI-DIRECTIONAL EMISSIONS FOR IMMUNITY TESTING 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements

 

ELECTROMAGNETIC FIELD EMISSION METER OF ELECTRIC TRANSMISSION ELECTRIC POWER LINES ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings